HIOKI AC CLAMP METER 3280-10F
SPECIFICATIONS
- AC Current range : 41.99 to 1000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy: ±1.5 % rdg. ±5 dgt.
- DC Voltage range : 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.
- AC Voltage range : 4.199 V to 600 V, 4 ranges (45 to 500 Hz, Average rectified), Basic accuracy: ±1.8 % rdg. ±7 dgt.\
- Resistance range : 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.
- Other functions : Continuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter
- Display : LCD, max. 4199 dgt., Display refresh rate: 400 ms
- Environmental protection : IP40 dustproof and waterproof
- Power supply : Coin type lithium battery (CR2032) ×1, Continuous use 120 hours
- Core jaw dia. : φ 33 mm (1.30 in)
- Dimensions and mass : 57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz)
FEATURES
- Measure the fundamental waveform component using the average rectified method
- Expanded -25°C to 65°C operating temperature range
- Connect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires
- Drop proof design withstands drop from a height of 1 meter
-
HIOKI AC/DC CLAMP METER CM4371-50
SPECIFICATIONS
- DC Current range : 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
- AC Current range : 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A
- Crest factor : 20.00 A range: 7.5 ; 600.0 A range: 3 or less
- DC+AC Current range : 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
- DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
- AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
- DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
- Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
- Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
- Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
- Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
- Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
- Dustproof, waterproof : IP54 (Storage or measurement of current of an insulated conductor)
- Core jaw diameter : φ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in)
- Power supply : LR03 Alkaline battery ×2 ; Continuous use: 40 hr (without Z3210 installed), 20 hr. (with Z3210 installed and using wireless communications) ; Other conditions: 10 A AC measurement, backlight off, 23°C reference value
FEATURES
- CAT IV 600 V, CAT III 1000 V When using the P2000: CAT III 2000 V, CAT IV 1000 V
- Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file
- Harmonic analysis from 1st to 30th order with our free app GENNECT Cross
- Automatic AC/DC function helps boost work efficiency
-
HIOKI AC/DC CLAMP METER CM4373-50
SPECIFICATIONS
- DC Current Range : 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)
- AC Current Range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)
- Crest factor : 600.0 A range: 3 or less ; 2000 A range: 2.84 or less
- DC+AC Current range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)
- DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
- AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
- DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
- Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
- Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
- Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
- Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
- Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
FEATURES
- CAT IV 600 V, CAT III 1000 V
When using P2000: CAT III 2000 V, CAT IV 1000 V - Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
- Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
- Automatic AC/DC function helps boost work efficiency
-
HIOKI BATTERY TESTER BT3554-51
SPECIFICATIONS
- Resistance measurement range : 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges
- Accuracy : ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)
- Testing source frequency : 1 kHz ±30 Hz
- Voltage measurement range : ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges
- Temperature measurement accuracy : -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F)
- Absolute max. input voltage : 60 V DC max. (No AC input)
- Measurement time : 100 ms
- Response time : Approx. 1.6 sec.
- Power supply : LR6 (AA) Alkaline dry battery ×8
- Continuous operating time: About 8.3 hr. (without Z3210 installed), About 8.2 hr. (with Z3210 installed and wireless communications active)
- Communication interface : USB Bluetooth® wireless communications (when Z3210 installed)
FEATURES
- Battery measurement can be performed while the battery is connected to its host device, without taking it offline
- Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554
- Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage (*1)
- Noise reduction technology improves noise resistance
- Screen and audio (*2) guidance simplifies measurement
- Measurement data is linked to site information and saved, reducing management man-hours
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross (*3) or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- New protector delivers better ergonomic hold and durability in the field.
-
HIOKI CLAMP ON AC/DC HiTESTER 3288-20
SPECIFICATIONS
- DC Current range : 100.0/ 1000 A, Basic accuracy: ±1.5 % rdg. ±5 dgt.
- AC Current range : 100.0/ 1000 A, (10 Hz to 500 Hz, True RMS), Basic accuracy: ±1.5 % rdg. ±5 dgt.
- DC Voltage range : 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt.
- AC Voltage range : 4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to 500 Hz, True RMS)
- Resistance range : 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.
- Other functions : Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power save, Auto zero (DC A)
- Display : LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s
- Power supply : Coin type lithium battery (CR2032) ×1, Continuous use 35 hours
- Core jaw dia. : φ 35 mm (1.38 in)
- Dimensions and mass : 57 mm (2.24 in) W × 180 mm (7.09 in) H × 16 mm (0.63 in) D, 150 g (5.3 oz)
FEATURES
- Voltage, resistance, and continuity check functions
- Use the 3288 for high current measurements such as UPS emergency batteries and train motors
-
HIOKI CM-4001 Ac Leakage Clampmeter
SPECIFICATIONS
- AC Current Range : 60.00 mA/ 600.0 mA/ 6.000 A/ 60.00 A/ 600.0 A, 5 ranges (40 Hz to 1 kHz, True RMS)
Accuracy : (45-66 Hz): ±1.5% rdg ±5 dgt (60.00 mA to 6.000 A), ±2.5% rdg ±5 dgt (60.00 A to 600.0 A) - Frequency range : 40.0 Hz to 999.9 Hz
- Crest factor : 4.5 (4000 counts or less)
3 (more than 4000 counts, 6000 counts or less) - Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
- Display : Display refresh rate: 5 times/s
- Core Jaw Diameter : φ 24 mm (0.94 in)
- Dimensions : 37 mm (1.46 in) W × 160 mm (6.30 in) H × 27 mm (1.06 in) D
- Mass : 115 g (4.1 oz.)
- Included Accessories : Carrying case × 1, Strap × 1, Instruction manual × 1, Operating Precautions × 1, LR03 alkaline battery × 1
FEATURES
- Find issues faster with comparator function
- Identify intermittent GFCI and RCD trips to prevent unplanned equipment downtime by testing for earth leakage current
- Measure everything from leakage to load
- Slim jaws let you work with ease
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- AC Current Range : 60.00 mA/ 600.0 mA/ 6.000 A/ 60.00 A/ 600.0 A, 5 ranges (40 Hz to 1 kHz, True RMS)
-
HIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function)
SPECIFICATIONS
- AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
Defined Accuracy Range : 0.060 mA to 200.0 A - Frequency range : 15.0 Hz to 2000 Hz
- Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
- Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
- Output Function : RMS (RMS value output), WAVE (waveform output)
- Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross. - Display : Display refresh rate: 5 times/s
- Core Jaw Diameter : φ 40 mm (1.57 in.)
- Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
- Mass : 400 g (14.1 oz.)
- Included Accessories : Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
- Broad measurement range extending from leakage currents to load currents
- Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
- Solve GFCI and RCD problems quickly
- Speed up pass/fail judgments with the built-in comparator function
- Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
- External power supply: use an optional AC adapter for continuous, long-term measurement
- CAT III 300 V
- AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
-
HIOKI CM4002 AC LEAKAGE CLAMP METER
SPECIFICATIONS
- AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
Defined Accuracy Range : 0.060 mA to 200.0 A - Frequency range : 15.0 Hz to 2000 Hz
- Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
- Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
- Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross - Core Jaw Diameter : φ 40 mm (1.57 in.)
- Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
- Mass : 400 g (14.1 oz.)
- Included Accessories : Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
- CAT IV 300 V
CAT III 600 V - Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
- Solve GFCI and RCD problems quickly
- Broad measurement range extending from leakage currents to load currents
- Speed up pass/fail judgments with the built-in comparator function
- AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
-
HIOKI DT-4252 Digital Multimeter
SPECIFICATIONS
- DC Voltage range : 600.0 mV to 1000 V, 5 ranges
Accuracy : ±0.3 % rdg. ±5 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) - Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges
Basic Accuracy : ±0.7 % rdg. ±5 dgt. - DC Current range : 6.000 A / 10.00 A, 2 ranges
Accuracy : ±0.9 % rdg. ±5 dgt. - AC Current range : 6.000 A / 10.00 A, 2 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt.(True RMS, crest factor 3, 40 Hz to 1 kHz) - Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt. - Frequency Range : AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V)
Accuracy : ±0.1 % rdg. ±1 dgt. - Continuity Check : Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more Response time: 0.5 ms or more
- Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
- Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
- Mass : 390 g (13.8 oz) (including batteries and holster)
- Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
- ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
- Measure up to 10A with direct input
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- USB communications function supports PC measurements (optional)
- Dual display lets you check voltage and frequency simultaneously
- DC Voltage range : 600.0 mV to 1000 V, 5 ranges
-
HIOKI DT-4253 Digital Multimeter
SPECIFICATIONS
- DC Voltage range : 600.0 mV to 1000 V, 5 ranges
Accuracy : ±0.3 % rdg. ±5 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) - Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges
Basic Accuracy : ±0.7 % rdg. ±5 dg - DC Current range : 60.00 μA to 60.00 mA, 4 ranges
Accuracy : ±0.8 % rdg. ±5 dgt. - AC Current range : 10.00 A to 1000 A, 7 range
Accuracy : 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) - Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt. - Frequency Range : 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage)
Accuracy : ±0.1 % rdg. ±1 dgt. - Continuity Check : Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more Response time: 0.5 ms or more
- Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
- Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
- Mass : 390 g (13.8 oz) (including batteries and holster)
- Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
- Ideal for measuring currents ranging from instrumentation signals (4 to 20 mA) to flame currents (μA) with built in high-sensitivity current ranges (DT4253)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Dual display lets you check voltage and frequency simultaneously
- DC Voltage range : 600.0 mV to 1000 V, 5 ranges
-
HIOKI DT-4254 Digital Multimeter
SPECIFICATIONS
- DC Voltage range : 600.0 mV to 1700 V (*1) 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) - Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Frequency Range : 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Basic accuracy : ±0.1 % rdg. ±1 dgt. - Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
- Mass : 390 g (13.8 oz) (including batteries and holster)
- Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
- The voltage measurement model, which is ideal for solar power system and power equipment management, measures up to 1700 V DC (*1) during open voltage inspections (DT4254)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
- Broad -25°C (-13°F) to 65°C (149°F) operating temperature range (DT4254, DT4255)
- Voltage detection function (DT4254, DT4255)
- Dual display lets you check voltage and frequency simultaneously
- DC Voltage range : 600.0 mV to 1700 V (*1) 5 ranges
-
HIOKI DT-4255 Digital Multimeter
SPECIFICATIONS
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) - Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
- AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Frequency Range : 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Accuracy : ±0.1 % rdg. ±1 dgt - Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt. - Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
- Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
- Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
- Mass : 390 g (13.8 oz) (including batteries and holster)
- Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
- Prevents short-circuit accidents with a fast-blow fuse and current-limiting resistor (DT4255)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
- Broad -25°C to 65°C (-13°F to 149°F) operating temperature range (DT4254, DT4255)
- Voltage detection function (DT4254, DT4255)
- Dual display lets you check voltage and frequency simultaneously
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
-
HIOKI DT-4256 Digital Multimeter
SPECIFICATIONS
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) - DC Current range : 60.00 mA to 10.00 A, 4 ranges,
Accuracy : ±0.9 % rdg. ±3 dgt. - AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) - Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt. - AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Frequency Range : 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current)
Accuracy : ±0.1 % rdg. ±1 dgt - Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt. - Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
- Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
- Other Functions : Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
- Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
- Mass : 390 g (13.8 oz) (including batteries and holster)
- Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
- ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- USB communications function supports PC measurements (optional)
- Broad -25°C to 65°C (-13°F to 149°F) operating temperature range
- Dual display lets you check voltage and frequency simultaneously
- Measure up to 10 A with direct input
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
-
HIOKI DT-4261 Digital Multimeter
SPECIFICATIONS
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.15 % rdg. ±2 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3 Or less) - AC+ DC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz
Accuracy : DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) - DC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : ±0.5 % rdg. ±3 dgt. - AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3 or less) - Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt. - AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges,
Basic accuracy 40 Hz – 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less) - Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt. - Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
- Diode Test : Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V
- Voltage frequency range : 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)
Basic accuracy: ±0.1% rdg. ±1 dgt. - Current frequency range : 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)
Basic accuracy: ±0.1% rdg. ±1 dgt. - Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D
- Mass : 480 g (16.9 oz.) (with test leads holder and batteries)
- Including Accessories : Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1
FEATURES
- Helping personnel analyze issues in the field
- Stop worrying about losing test lead caps
- Boost work efficiency with digitalization (Excel® Direct Input Function)
- Excellent dust and water resistance (compliant with the IP54 international standard)
- Ensuring safety by preventing erroneous test lead insertion (terminal shutters)
- Harmonic levels : [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross. - Other Functions : Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
-
HIOKI FT-3700-20 Infrared Thermometer
SPECIFICATIONS
- Measurement temperature range : -60.0˚C to 550.0˚C (-76˚F to 1022˚F), 0.1˚C resolution
- Accuracy :
-35.0˚C to -0.1˚C (-31.0˚F to 31.9˚F) : ±10 %rdg. ±2˚C
0.0˚C to 100.0˚C (-32.0˚F to 212.0˚F) : ±2˚C
100.1˚C to 500.0˚C (212.1˚F to 932.0˚F) : ±2% rdg.
Note: -60.0˚C to -35.1˚C (-76.0˚F to -31.1˚F), and over 500.1˚C (932.0˚F), Accuracy not specified - Response time : 1 sec (90%)
- Measurement Wavelength : 8 to 14 µm
- Thermal emissivity compensation : ε=0.10 to 1.00 (0.01 step)
- Measurement field diameter : ε=0.10 to 1.00 (0.01 step)
- Sighting : Two-beam laser marker Max 1 mW (class 2), Red
- Functions : Continuous measurement mode, MAX/ MIN/ DIF (MAX – MIN)/ AVG measurement, Alarm, Backlight, Auto power-off
- Dimensions and Mass : 48 mm (1.89 in) W × 172 mm (6.77 in) H × 119 mm (4.69 in) D, 256 g (9.0 oz), (including batteries)
- Included Accessories : Instruction manual ×1, LR03 alkaline battery ×2, Carrying case ×1
FEATURES
- Pistol design with easy-to-see display
- A full menu of basic measuring functions
- Easily test in difficult locations, moving objects or where there is danger of electric shock
-
HIOKI FT-6031-50 Earth Tester
SPECIFICATIONS
- Measurement System : Two-electrode method/three-electrode method (switchable)
- Measurement range / Accuracy :
20 Ω (0 Ω〜20.00 Ω) / ±1.5% rdg ±8 dgt
200 Ω (0 Ω〜200.0 Ω) / ±1.5% rdg ±4 dgt
2000 Ω (0 Ω〜2000 Ω) / ±1.5% rdg ±4 dgt - Earth voltage : 0〜30.0 V rms
Accuracy : ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC) - Allowable earth potential : 25.0 V rms (DC or sine wave)
- Dustproof and waterproof : IP65/IP67 (EN60529)
- Dimensions : 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D
- Mass : 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories)
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Excellent noise resistance
- IP67 protected – top of the industry
- Minimize cabling time with innovative earthing rods and cable winder
- Wide 0Ω to 2000Ω measurement range
- Test all ground types from Class A to Class D with a single meter