HIOKI DT-4256 Digital Multimeter
Read moreSPECIFICATIONS
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) - DC Current range : 60.00 mA to 10.00 A, 4 ranges,
Accuracy : ±0.9 % rdg. ±3 dgt. - AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) - Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt. - AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Frequency Range : 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current)
Accuracy : ±0.1 % rdg. ±1 dgt - Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt. - Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
- Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
- Other Functions : Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
- Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
- Mass : 390 g (13.8 oz) (including batteries and holster)
- Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
- ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- USB communications function supports PC measurements (optional)
- Broad -25°C to 65°C (-13°F to 149°F) operating temperature range
- Dual display lets you check voltage and frequency simultaneously
- Measure up to 10 A with direct input
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
-
HIOKI DT-4261 Digital Multimeter
Read moreSPECIFICATIONS
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.15 % rdg. ±2 dgt. - AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3 Or less) - AC+ DC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz
Accuracy : DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) - DC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : ±0.5 % rdg. ±3 dgt. - AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3 or less) - Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt. - AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges,
Basic accuracy 40 Hz – 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less) - Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt. - Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
- Diode Test : Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V
- Voltage frequency range : 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)
Basic accuracy: ±0.1% rdg. ±1 dgt. - Current frequency range : 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)
Basic accuracy: ±0.1% rdg. ±1 dgt. - Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Dimensions : 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D
- Mass : 480 g (16.9 oz.) (with test leads holder and batteries)
- Including Accessories : Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1
FEATURES
- Helping personnel analyze issues in the field
- Stop worrying about losing test lead caps
- Boost work efficiency with digitalization (Excel® Direct Input Function)
- Excellent dust and water resistance (compliant with the IP54 international standard)
- Ensuring safety by preventing erroneous test lead insertion (terminal shutters)
- Harmonic levels : [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross. - Other Functions : Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)
- DC Voltage range : 600.0 mV to 1000 V , 5 ranges
-
HIOKI FT-3700-20 Infrared Thermometer
Read moreSPECIFICATIONS
- Measurement temperature range : -60.0˚C to 550.0˚C (-76˚F to 1022˚F), 0.1˚C resolution
- Accuracy :
-35.0˚C to -0.1˚C (-31.0˚F to 31.9˚F) : ±10 %rdg. ±2˚C
0.0˚C to 100.0˚C (-32.0˚F to 212.0˚F) : ±2˚C
100.1˚C to 500.0˚C (212.1˚F to 932.0˚F) : ±2% rdg.
Note: -60.0˚C to -35.1˚C (-76.0˚F to -31.1˚F), and over 500.1˚C (932.0˚F), Accuracy not specified - Response time : 1 sec (90%)
- Measurement Wavelength : 8 to 14 µm
- Thermal emissivity compensation : ε=0.10 to 1.00 (0.01 step)
- Measurement field diameter : ε=0.10 to 1.00 (0.01 step)
- Sighting : Two-beam laser marker Max 1 mW (class 2), Red
- Functions : Continuous measurement mode, MAX/ MIN/ DIF (MAX – MIN)/ AVG measurement, Alarm, Backlight, Auto power-off
- Dimensions and Mass : 48 mm (1.89 in) W × 172 mm (6.77 in) H × 119 mm (4.69 in) D, 256 g (9.0 oz), (including batteries)
- Included Accessories : Instruction manual ×1, LR03 alkaline battery ×2, Carrying case ×1
FEATURES
- Pistol design with easy-to-see display
- A full menu of basic measuring functions
- Easily test in difficult locations, moving objects or where there is danger of electric shock
-
HIOKI FT-6031-50 Earth Tester
Read moreSPECIFICATIONS
- Measurement System : Two-electrode method/three-electrode method (switchable)
- Measurement range / Accuracy :
20 Ω (0 Ω〜20.00 Ω) / ±1.5% rdg ±8 dgt
200 Ω (0 Ω〜200.0 Ω) / ±1.5% rdg ±4 dgt
2000 Ω (0 Ω〜2000 Ω) / ±1.5% rdg ±4 dgt - Earth voltage : 0〜30.0 V rms
Accuracy : ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC) - Allowable earth potential : 25.0 V rms (DC or sine wave)
- Dustproof and waterproof : IP65/IP67 (EN60529)
- Dimensions : 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D
- Mass : 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories)
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Excellent noise resistance
- IP67 protected – top of the industry
- Minimize cabling time with innovative earthing rods and cable winder
- Wide 0Ω to 2000Ω measurement range
- Test all ground types from Class A to Class D with a single meter
-
HIOKI FT6380-50 Clamp On Earth Tester
Read moreSPECIFICATIONS
- Earth Resistance Range : 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω,
Accuracy: ±1.5 % rdg. ±0.02 Ω - AC Current Range : 20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA,
Accuracy: ±2.0 % rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less) - Maximum input current (Current measurement) : 100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50 Hz/60 Hz, requires derating at frequency)
- Maximum rated terminal-to-ground voltage : 600 VAC measurement category IV (anticipated transient overvoltage 8000 V)
- Memory Function : 2000 data
- Alarm Function : For resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold.
- Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross. - Other functions : Data hold, Backlight, Filter, Auto power save, Wireless communication (without Z3210 installed))
- Display : LCD, Max. 2,000 count Display refresh rate: Approx. 2 times/sec
- Dustproof and Waterproof : IP40 (EN60529) With Jaws Closed
- Power Supply : LR6 alkaline battery × 2
- Continuous Operating Time : Approx. 40 hours (25 Ω measurement, backlight off, without Z3210 installed)
Approx. 35 hours (25 Ω measurement, backlight off, with Z3210 installed and using wireless communications) - Maximum measurable conductor diameter : φ 32 mm (1.26 in)
- Dimensions : 73 mm (2.87 in) W × 218 mm (8.58 in) H × 43 mm (1.69 in) D
- Mass : 620 g (21.9 oz)
- Included Accessories : Carrying case, Resistance check loop (1 Ω±2%, 25Ω±1%), Strap, LR6 alkaline battery × 2, Instruction manual
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Measure load current up to 60.0 A range
- Clamp at the narrowest point
- Earth resistance measurement for multi-grounded systems
- Measure leak current with absolute certainty with highly sensitive 0.01 mA resolution (at 20.00 mA range)
Measurement Principle : Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated
Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value. - Earth Resistance Range : 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω,
-
HIOKI IR-3455 High Voltage Insulation Tester
Read moreSPECIFICATIONS
- Test Voltage : 250 V to 5.00 kV DC, (Possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kV)
- Measurement Range :
0.00 MΩ to 500 GΩ (250 V)
0.00 MΩ to 1.00 TΩ (500 V)
0.00 MΩ to 2.00 TΩ (1 kV)
0.00 MΩ to 5.00 TΩ (2.5 kV)
0.00 MΩ to 10.0 TΩ (5 kV) - Measurement Current : 1 mA (Test voltage 250 V to 1.00 kV), 0.5 mA (Test voltage 1.10 kV to 2.50 kV) 0.25 mA (Test voltage 2.60 kV to 5.00 kV), Short-circuit current: 2 mA or less
- Resistance Range : 10 MΩ to 10 TΩ, 7 ranges (auto range)
- Accuracy :
±5% rdg. ±5 dgt. Up to [Test voltage (setting value)/Resistance measurable at 100 nA]
±20% rdg. ±5 dgt. [Test voltage (setting value)/Resistance measurable at 100 nA] to [Test voltage (setting value)/Resistance measurable at 1 nA] or 500 GΩ
±30% rdg. ±50 dgt. [Test voltage (setting value)/Resistance measurable at 1 nA] or 501 GΩ to 9.99 TΩ - Leakage current measurement : 1.00 nA to 1.20 mA, 6 ranges (current measurement that occurs when test voltage is generated)
Accuracy ±2.5% rdg. ±5 dgt. (1 mA range); refer to complete catalog for other ranges - Voltage measurement : ±50 V to ±1.00 kV DC, 50 V to 750 V AC (50/60 Hz),
Accuracy: ±5 % rdg. ±5 dgt. , Input resistance: Approx. 10 MΩ - Temperature measurement : -10.0 ˚C to 70.0 ˚C, 3 ranges (used with optional sensor)
Accuracy ±1.0 ˚C (0.0 ˚C to 40.0 ˚C); refer to complete catalog for other ranges - Other Functions : Insulation Diagnosis (Temperature compensation, PI/DAR display, Step voltage test), Data memory, Communication (USB 2.0, PC application software), auto discharge, hot conductor warning indication, etc.
- Digital LCD, max. 999 dgt. with backlight, Bar graph display
- Dimensions and Mass : 260 mm (10.24 in)W × 250.6 mm (9.87 in)H × 119.5 mm (4.70 in)D, 2.8 kg (98.8 oz)
- Included Accessories : Test lead 9750-01 ×1, Test lead 9750-02 ×1, Test lead 9750-03 ×1, Alligator clip 9751-01 ×1, Alligator clip 9751-02 ×1, Alligator clip 9751-03 ×1, Instruction manual ×1, LR6 (AA) alkaline batteries ×6, USB cable ×1, PC application software (CD-R) ×1
FEATURES
- Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
- Wide testing voltage range, up to 5.00 kV from 250 V DC
- Wide measurement insulation range, up to 10 TΩ
- PI (Polarization Index) and DAR (Dielectric Absorption Ratio) automatically calculated / display
- Extended operating temperature range of -10°C to 50°C
- Data memory function to reduce handwritten notes
- Bright LED luminous scale
-
HIOKI P2000 DC High Voltage Probe
Read moreSPECIFICATIONS
- Maximum Input Voltage : DC 2000 V
- Maximum rated line-to-ground voltage
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V - Input Resistance : 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
- Overload Protection :
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) - Output Terminal : 4 mm banana terminal
- Operating Temperature Range : -25°C to 65°C (-13°F to 149°F)
- Operating Humidity Range : −25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing)
40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) - Storage temperature and humidity range : -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing)
- Standards : EN 61010
- Included Accessories : Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1
FEATURES
- Enables high voltage measurement up to CAT Ⅲ 2000 V
- Safely measure solar installations like the mega-solar without interrupting the grid
- Connects to compatible Hioki clamp meters and digital multimeters (DMMs)
ACCURACY FOR COMPATIBLE INSTRUMENTS
- DT-4261 :
Range 600.0 V: Combined accuracy ±0.5% rdg ±0.2 V
Range 2000 V: Combined accuracy ±0.5% rdg ±5 V - CM4141-50 ; CM4371-50 ; CM4373-50 ; CM4375-50 :
Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V
Range 2000 V: Combined accuracy ±1.0% rdg ±3 V - DT-4282 ; DT-4281 :
Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10) - DT-4252 ; DT-4253 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10) - DT-4255 ; DT-4256 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10)