HIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function)

Brands:

Availability: In Stock

SPECIFICATIONS 

  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
    Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
    Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
    Defined Accuracy Range : 0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Output Function : RMS (RMS value output), WAVE (waveform output)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
    *Harmonics can be displayed with our free app GENNECT Cross.
  • Display : Display refresh rate: 5 times/s
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2

FEATURES

  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Broad measurement range extending from leakage currents to load currents
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • Solve GFCI and RCD problems quickly
  • Speed up pass/fail judgments with the built-in comparator function
  • Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
  • External power supply: use an optional AC adapter for continuous, long-term measurement
  • CAT III 300 V

Description

CM4002 AND CM4003

Reviews

There are no reviews yet.

Be the first to review “HIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function)”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function) removeMECO-G R-2070D DIGITAL CLAMPMETER removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER removeMECO 72T AUTO BL CLAMP METER removeMECO 27 AUTO BL 3.5 DIGITS DIGITAL CLAMP METER remove
NameHIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function) removeMECO-G R-2070D DIGITAL CLAMPMETER removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER removeMECO 72T AUTO BL CLAMP METER removeMECO 27 AUTO BL 3.5 DIGITS DIGITAL CLAMP METER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS 
  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Accuracy : 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Accuracy : 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt Defined Accuracy Range : 0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Output Function : RMS (RMS value output), WAVE (waveform output)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio *Harmonics can be displayed with our free app GENNECT Cross.
  • Display : Display refresh rate: 5 times/s
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Broad measurement range extending from leakage currents to load currents
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • Solve GFCI and RCD problems quickly
  • Speed up pass/fail judgments with the built-in comparator function
  • Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
  • External power supply: use an optional AC adapter for continuous, long-term measurement
  • CAT III 300 V
SPECIFICATIONS :
  • DC CURRENT  : 600A
  • AC CURRENT : 600A
  • AC VOLTAGE : 600V
  • DC VOLTAGE : 600V
  • DISPLAY : 3 5/6 digit,6000
  • BETTERY : 9V (6F22)
  • TEMPERATURE : 600°C
  • CAPACITANCE : 1000uF
  • FREQUENCY : 10 MHz
  • RESISTANCE : 60MΩ
    FEATURES:
  • Op. Current <2mA (no back light).
  • LCD Display,
  • Auto / Manual Ranging, Data Hold.
  • NCV APO, Temperature, Frequency, Max Hold.
  • Diode Test, Resistance, Duty Cycle.
  • Continuity Buzzer, Backlight, Trms.
  • Low Battery Indicated.
  • Duty Cycle : 0.1% - 99.9%.
   
SPECIFICATIONS:
  • DC Voltage: 2000V
  • AC Voltage: 2000V
  • DC Current: 2000A
  • AC Current: 2000A
  • Resistance: 20 M ohms
  • Capacitance: 2000uF
  FEATURES
  • Display Mode: Display by LCD
  • Maximum Display: 1999
  • Digits: 3 ½ Digits
  • Maximum span of jaw: 55mm
  • Auto Range
  • Inrush Current
  • Resistance
  • Capacitance
  • Diode Test
  • Continuity Test
  • Data Hold
  • LED Testing
  • Back Light + Lamp Light
  • Auto negative polarity indication: displaying ‘-’
  • Auto Power Off
  • Battery: 9V
 
SPECIFICATIONS : 
  • DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
  • AC VOLTAGE : 4V, 40V, 400V, 750V
  • RESISTANCE : 4000, 4kQ, 40KQ, 400kQ, 4MQ, 40MQ (auto ranging)
  • DIMENSIONS : 229x69x38 mm
FEATURES : 
  • 1000A AC auto ranging. 3 digit 3999 counts. Data hold, frequency, capacitance. APO ranges.
SPECIFICATIONS : 
  • DC VOLTAGE : 400 mV-600 V
  • AC VOLTAGE : 0-600 V
  • AC CURRENT : ?(2.5 % + 5 Digits)
  • DC CURRENT : ?(0.8 % + 3 Digits)
  • DC ACCURACY : ?(0.8 % + 3 Digits)
  • AC ACCURACY : ?(1.2 % + 3 Digits)
FEATURES : 
  • Auto Power off.
  • Data Hold Function.
  • Audible Continuity Test.
  • Diode Test Functions.
  • Low Battery Indications.
  • Function Button, Hold Button & Rel Button.
SPECIFICATIONS :
  • DC VOLTAGE : 600V
  • AC VOLTAGE : 600V
  • AC CURRENT : 400A
  • RESISTANCE : 20MV
  • STORAGE TEMPERATURE : -20°C to 60°C, 0 to 80% R.H.
  • OPERATING ENVIORNMENT : 0°C to 50°C at < 70% relative humidity.
  • Dimensions : 185 x 65 x 28mm
  • Weight : 170gms including battery.
FEATURES:
  • DISPLAY : 3½ digit liquid crystal display (LCD)
  • LOW BATTERY INDICATION : is displayed when the battery voltage drops below the operating level.
  • Weight : 170gms including battery (approx.)
  • Maximum Jaw : 25mm
 
ContentCM4002 AND CM4003MECO-G TRMS Clamp Meter, R-2070D is a premium quality product from MECO-G. All MECO-G TRMS Clamp Meter, R-2070D are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G TRMS Clamp Meter, R-2070D, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Clamp Meters .B-6096 is a 2000V AC/DC and 2000A AC/DC TRUE RMS Digital Clamp meter. It adopts high performance MCU processor. It is of great value as it has high reliability, accuracy, quality and automatic setting range function. The product has a large digital display, full range overload protection, data hold function, under voltage detection, auto shut off function. The TRUE RMS function can accurately measure frequency voltage, suitable for measuring motor and compressor starting current. Along with AC/DC current, AC/DC voltage it can measure resistance, capacitance, continuity test, diode forward voltage drop, LED operating voltage, and other parameters. This instrument is easy to operate and carry making it an ideal tool for electrical measurement. Especially suitable for measuring large currents and starting currents.    Meco Digital Clamp Meter 3150 comes with a number of interesting features such as 3 digit 3999 counts frequency data hold APO ranges and capacitance. It comes with a resistance of 4000 4kQ 40KQ 400kQ 4MQ 40MQ. Highly rated by technical experts this digital clamp meter from Meco is suitable for use in DIY projects as well as industries.
All Meco 72T-Auto Digital AC Clamp Meter 400 A 600 V are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture Meco 72T-Auto Digital AC Clamp Meter 400 A 600 V, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. Meco products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of Meco Clamp Meters .
This Meco Digital Clamp Meter is an auto-ranging clamp meter having a massive 2000 count of 3.5 digits. In addition, one of the biggest advantages of this automated Meco clamp meter is that it can hold a large quantity of data too. The clamp meter has an LCD display and also comes with an auto power-off function. It displays OT and -OI both, and this clamp meter has a function button, hold button and max button. This clamp meter is automatic, positive implied and negative polarity indication.
Weight
DimensionsN/AN/AN/AN/AN/AN/A