HIOKI AC/DC CLAMP METER CM4371-50

Brands:
Category:

Availability: In Stock

SPECIFICATIONS

  • DC Current range : 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
  • AC Current range :  20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A
  • Crest factor : 20.00 A range: 7.5 ; 600.0 A range: 3 or less
  • DC+AC Current range : 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
  • DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
  • AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
  • DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
  • Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
  • Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
  • Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
  • Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
  • Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
  • Dustproof, waterproof : IP54 (Storage or measurement of current of an insulated conductor)
  • Core jaw diameter : φ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in)
  • Power supply : LR03 Alkaline battery ×2 ; Continuous use: 40 hr (without Z3210 installed), 20 hr. (with Z3210 installed and using wireless communications) ; Other conditions: 10 A AC measurement, backlight off, 23°C reference value

FEATURES

  • CAT IV 600 V, CAT III 1000 V When using the P2000: CAT III 2000 V, CAT IV 1000 V
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file
  • Harmonic analysis from 1st to 30th order with our free app GENNECT Cross
  • Automatic AC/DC function helps boost work efficiency
Category:

Description

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Model CM4371-50 is a 600 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.

Reviews

There are no reviews yet.

Be the first to review “HIOKI AC/DC CLAMP METER CM4371-50”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHIOKI AC/DC CLAMP METER CM4371-50 removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER removeMECO-G R-2070D DIGITAL CLAMPMETER removeHTC CM 2000 - 600A AC Clamp Meter removeBEETECH M-266 DIGITAL CLAMP METER 1000A AC removeMECO-G R2025THz DIGITAL CLAMPMETER remove
NameHIOKI AC/DC CLAMP METER CM4371-50 removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER removeMECO-G R-2070D DIGITAL CLAMPMETER removeHTC CM 2000 - 600A AC Clamp Meter removeBEETECH M-266 DIGITAL CLAMP METER 1000A AC removeMECO-G R2025THz DIGITAL CLAMPMETER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS
  • DC Current range : 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
  • AC Current range :  20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A
  • Crest factor : 20.00 A range: 7.5 ; 600.0 A range: 3 or less
  • DC+AC Current range : 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
  • DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
  • AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
  • DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 - 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
  • Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
  • Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
  • Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
  • Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
  • Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
  • Dustproof, waterproof : IP54 (Storage or measurement of current of an insulated conductor)
  • Core jaw diameter : φ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in)
  • Power supply : LR03 Alkaline battery ×2 ; Continuous use: 40 hr (without Z3210 installed), 20 hr. (with Z3210 installed and using wireless communications) ; Other conditions: 10 A AC measurement, backlight off, 23°C reference value
FEATURES
  • CAT IV 600 V, CAT III 1000 V When using the P2000: CAT III 2000 V, CAT IV 1000 V
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file
  • Harmonic analysis from 1st to 30th order with our free app GENNECT Cross
  • Automatic AC/DC function helps boost work efficiency
SPECIFICATIONS : 
  • DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
  • AC VOLTAGE : 4V, 40V, 400V, 750V
  • RESISTANCE : 4000, 4kQ, 40KQ, 400kQ, 4MQ, 40MQ (auto ranging)
  • DIMENSIONS : 229x69x38 mm
FEATURES : 
  • 1000A AC auto ranging. 3 digit 3999 counts. Data hold, frequency, capacitance. APO ranges.
SPECIFICATIONS :
  • DC CURRENT  : 600A
  • AC CURRENT : 600A
  • AC VOLTAGE : 600V
  • DC VOLTAGE : 600V
  • DISPLAY : 3 5/6 digit,6000
  • BETTERY : 9V (6F22)
  • TEMPERATURE : 600°C
  • CAPACITANCE : 1000uF
  • FREQUENCY : 10 MHz
  • RESISTANCE : 60MΩ
    FEATURES:
  • Op. Current <2mA (no back light).
  • LCD Display,
  • Auto / Manual Ranging, Data Hold.
  • NCV APO, Temperature, Frequency, Max Hold.
  • Diode Test, Resistance, Duty Cycle.
  • Continuity Buzzer, Backlight, Trms.
  • Low Battery Indicated.
  • Duty Cycle : 0.1% - 99.9%.
   
SPECIFICATION:
  • DC VOLTAGE       : 600V
  • AC VOLTAGE       : 600V
  • AC CURRENT       : 600A
  • RESISTANCE       : 20 M ohms
  • TEMPERATURE  : Range (-40~750)°C Resolution 1°C                                                                                                                                                                                                                                                                                                                    Accuracy - <400°C±1.0% of rdg + 5 digits ≥400°C±1.5% of rdg + 15 digits
  FEATURES:
  • 3½ Digit
  • 2000 Count
  • Non Contact Voltage (NCV)
  • Clamp Torch
  • Jaw Open: 28mm
  • Auto Power Off (APO)
  • True RMS
SPECIFICATION
  • AC current : 1000A
  • AC Voltage : 750V
  • DC Voltage : 1000V
  • Resistance : 20KΩ
  • Insulation test : 2000MΩ
  • Audible continuity : Overload Protection 15s maximum 250Vrms
FEATURES
  •  Display Mode: 3 1/2 LCD
  •  Maximum Display: 1999, 0.5” high
  •  Maximum Span of Jaw: 53mm
  •  Auto Polarity Indication: Displaying “-”, assumed “+”
  •  Sampling speed: 2 times/s
  •  Over-load indication: “1” is displayed
  •  Low battery indication
  •  Power supply: 9V
  •  Dimensions: 230 x 68 x 37mm
  •  Weight: ≈ 240g (battery included)
  •  Static electricity: ≈ 4mA
  •  Operating environment: 0˚C ~ 40˚C, at <80% RH
  •  Storage environment: -10 ˚C ~ 50˚C at <85% RH
SPECIFICATIONS :
  • DC VOLTAGE : 1000V
  • AC VOLTAGE : 750V
  • ACCURRENT : 1000V
  • RESISTANCE : 60M ohms
  • TEMPERATURE : -40~2000℉
FEATURES : 
  • TRANSFORMER JAWS
  • TRIGGER
  • Hz/DUTY BUTTON
  • RANGE BUTTON
  • 3 5/6 DIGIT LCD DISPLAY
  • "V" INPUT TERMINAL
  • "COM" TERMINAL
  • SELECT BUTTON
  • FUNCTION SWITCH /RANGE SWITCH
  • D. HOLD BUTTON
ContentHioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Model CM4371-50 is a 600 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.Meco Digital Clamp Meter 3150 comes with a number of interesting features such as 3 digit 3999 counts frequency data hold APO ranges and capacitance. It comes with a resistance of 4000 4kQ 40KQ 400kQ 4MQ 40MQ. Highly rated by technical experts this digital clamp meter from Meco is suitable for use in DIY projects as well as industries.MECO-G TRMS Clamp Meter, R-2070D is a premium quality product from MECO-G. All MECO-G TRMS Clamp Meter, R-2070D are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G TRMS Clamp Meter, R-2070D, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Clamp Meters .HTC Brand best quality Digital 3 ½ digits 600A clamp tester model CM-2000 having AC Voltage from 200mV to 600V, DC Voltage from 200mV to 600v (auto ranging), Ac current  in four ranges (0-2-20-200-600A), Resistance (auto ranging) from 0- 20 M.Ohms, with NCV test, Diode test, sound buzzer in continuity,  data hold, clamp led light.  Instrument is supplied with carrying case, test probes, installed 1.5v cells and instruction manual.BEETECH M266 Digital AC Clamp Meter is a versatile and easy-to-use clamp meter that can measure AC current, AC/DC voltage, resistance, and continuity. It is perfect for use in a variety of applications, including electrical maintenance, HVAC/R, automotive, and more. The clamp meter is a precision instrument that is perfect for a wide range of applications. It is affordably priced and has exceptional quality. This clamp meter is easy to use and has a wide variety of features that make it perfect for any measuring need.The MECO-G 1000A AC Digital Auto Ranging Clamp Meter is a great choice for those who need a reliable and accurate clamp meter. It features a large jaw opening for easy clamping, auto ranging for easy use, and a backlit LCD display for easy reading. The MECO-G clamp meter is a great choice for measuring dc voltage and current, as well as ac current. It has a range of 600mV to 6V, 60V to 600V, and 1000V, making it suitable for a variety of applications. The ac current range is 60A to 600A, and 1000A, with an accuracy of  (2.5% of reading + 10 digits). The clamp meter also features a resistance accuracy of  (1.5% of reading + 5 digits).
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information