Screen and audio (*2) guidance simplifies measurement
Measurement data is linked to site information and saved, reducing management man-hours
Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross (*3) or to an Excel® file. (Wireless Adapter Z3210 is necessary)
New protector delivers better ergonomic hold and durability in the field.
AC Current Range : 60.00 mA/ 600.0 mA/ 6.000 A/ 60.00 A/ 600.0 A, 5 ranges (40 Hz to 1 kHz, True RMS)
Accuracy : (45-66 Hz): ±1.5% rdg ±5 dgt (60.00 mA to 6.000 A), ±2.5% rdg ±5 dgt (60.00 A to 600.0 A)
Frequency range : 40.0 Hz to 999.9 Hz
Crest factor : 4.5 (4000 counts or less)
3 (more than 4000 counts, 6000 counts or less)
Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
Display : Display refresh rate: 5 times/s
Core Jaw Diameter : φ 24 mm (0.94 in)
Dimensions : 37 mm (1.46 in) W × 160 mm (6.30 in) H × 27 mm (1.06 in) D
Identify intermittent GFCI and RCD trips to prevent unplanned equipment downtime by testing for earth leakage current
Measure everything from leakage to load
Slim jaws let you work with ease
Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
Defined Accuracy Range : 0.060 mA to 200.0 A
Frequency range : 15.0 Hz to 2000 Hz
Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
Output Function : RMS (RMS value output), WAVE (waveform output)
Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Display : Display refresh rate: 5 times/s
Core Jaw Diameter : φ 40 mm (1.57 in.)
Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
Broad measurement range extending from leakage currents to load currents
Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
Solve GFCI and RCD problems quickly
Speed up pass/fail judgments with the built-in comparator function
Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
External power supply: use an optional AC adapter for continuous, long-term measurement
AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
Defined Accuracy Range : 0.060 mA to 200.0 A
Frequency range : 15.0 Hz to 2000 Hz
Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross
Core Jaw Diameter : φ 40 mm (1.57 in.)
Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
CAT IV 300 V
CAT III 600 V
Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
Solve GFCI and RCD problems quickly
Broad measurement range extending from leakage currents to load currents
Speed up pass/fail judgments with the built-in comparator function
DC Voltage range : 600.0 mV to 1000 V, 5 ranges
Accuracy : ±0.3 % rdg. ±5 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges
Basic Accuracy : ±0.7 % rdg. ±5 dg
DC Current range : 60.00 μA to 60.00 mA, 4 ranges
Accuracy : ±0.8 % rdg. ±5 dgt.
AC Current range : 10.00 A to 1000 A, 7 range
Accuracy : 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt.
Frequency Range : 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage)
Accuracy : ±0.1 % rdg. ±1 dgt.
Continuity Check : Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more Response time: 0.5 ms or more
Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
Mass : 390 g (13.8 oz) (including batteries and holster)
Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
Ideal for measuring currents ranging from instrumentation signals (4 to 20 mA) to flame currents (μA) with built in high-sensitivity current ranges (DT4253)
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
Dual display lets you check voltage and frequency simultaneously
DC Voltage range : 600.0 mV to 1700 V (*1) 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
Frequency Range : 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Basic accuracy : ±0.1 % rdg. ±1 dgt.
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
Mass : 390 g (13.8 oz) (including batteries and holster)
Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
The voltage measurement model, which is ideal for solar power system and power equipment management, measures up to 1700 V DC (*1) during open voltage inspections (DT4254)
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
Broad -25°C (-13°F) to 65°C (149°F) operating temperature range (DT4254, DT4255)
Voltage detection function (DT4254, DT4255)
Dual display lets you check voltage and frequency simultaneously
DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
Frequency Range : 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Accuracy : ±0.1 % rdg. ±1 dgt
Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt.
Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
Mass : 390 g (13.8 oz) (including batteries and holster)
Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
Prevents short-circuit accidents with a fast-blow fuse and current-limiting resistor (DT4255)
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
Broad -25°C to 65°C (-13°F to 149°F) operating temperature range (DT4254, DT4255)
Voltage detection function (DT4254, DT4255)
Dual display lets you check voltage and frequency simultaneously
DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
DC Current range : 60.00 mA to 10.00 A, 4 ranges,
Accuracy : ±0.9 % rdg. ±3 dgt.
AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz)
Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt.
AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
Frequency Range : 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current)
Accuracy : ±0.1 % rdg. ±1 dgt
Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt.
Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
Other Functions : Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
Mass : 390 g (13.8 oz) (including batteries and holster)
Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
USB communications function supports PC measurements (optional)
Broad -25°C to 65°C (-13°F to 149°F) operating temperature range
Dual display lets you check voltage and frequency simultaneously
DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.15 % rdg. ±2 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3 Or less)
AC+ DC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz
Accuracy : DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
DC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : ±0.5 % rdg. ±3 dgt.
AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3 or less)
Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt.
AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges,
Basic accuracy 40 Hz – 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less)
Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt.
Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode Test : Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V
Voltage frequency range : 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Current frequency range : 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D
Mass : 480 g (16.9 oz.) (with test leads holder and batteries)
Including Accessories : Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1
FEATURES
Helping personnel analyze issues in the field
Stop worrying about losing test lead caps
Boost work efficiency with digitalization (Excel® Direct Input Function)
Excellent dust and water resistance (compliant with the IP54 international standard)
Ensuring safety by preventing erroneous test lead insertion (terminal shutters)
Harmonic levels : [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Other Functions : Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)
Measurement temperature range : -60.0˚C to 550.0˚C (-76˚F to 1022˚F), 0.1˚C resolution
Accuracy :
-35.0˚C to -0.1˚C (-31.0˚F to 31.9˚F) : ±10 %rdg. ±2˚C
0.0˚C to 100.0˚C (-32.0˚F to 212.0˚F) : ±2˚C
100.1˚C to 500.0˚C (212.1˚F to 932.0˚F) : ±2% rdg.
Note: -60.0˚C to -35.1˚C (-76.0˚F to -31.1˚F), and over 500.1˚C (932.0˚F), Accuracy not specified
Response time : 1 sec (90%)
Measurement Wavelength : 8 to 14 µm
Thermal emissivity compensation : ε=0.10 to 1.00 (0.01 step)
Measurement field diameter : ε=0.10 to 1.00 (0.01 step)
Sighting : Two-beam laser marker Max 1 mW (class 2), Red
Earth voltage : 0〜30.0 V rms
Accuracy : ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC)
Allowable earth potential : 25.0 V rms (DC or sine wave)
Dustproof and waterproof : IP65/IP67 (EN60529)
Dimensions : 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D
Mass : 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories)
FEATURES
Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
Excellent noise resistance
IP67 protected – top of the industry
Minimize cabling time with innovative earthing rods and cable winder
Wide 0Ω to 2000Ω measurement range
Test all ground types from Class A to Class D with a single meter