Showing 353–357 of 357 results

  • SELEC VFD-S-1-010-230V / VFD-S-1-020-230V

    SPECIFICATIONS

    • AC Input Voltage Range : Single Phase: 230V
    • Frequency Range : 50Hz/60Hz
    • Control Mode : Scalar Control Based Space Vector PWM
    • Frequency Control Range : 0.1~400 Hz
    • Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
    • Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
    • Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
    • Ingress Protection : IP20
    • Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
    • Output Current :
      VFD-S-1-010-230V : 5A
      VFD-S-1-020-230V : 7A

    FEATURES

    • 4 Pre-set V/F; 1 user defined V/F Program
    • Input: Single phase 230V, 50Hz/60Hz
    • Output: Three phase 230VAC, 0-400Hz
    • Output power: 0.5 HP/0.4KW TO 2HP/1.5 KW
    • 5 (PNP/NPN) Inputs, 1 POT Input, 1 Analog Inputs(0-10V/0-20mA/4-20mA), 1 Relay Output, 1 Analog Output(0-10V/0-20mA); 1 Open collector output
    • Supports RS485 Modbus Communication protocol
    • Provides protection against Over current, Over Voltage, Under Voltage, Over Temperature, Overload and Under current, System error.
    • Suitable for application like Pumps, Fans, Conveyor, Food; drink packaging machinery, Industrial washing machine and most general industries etc
    Read more
  • SELEC VFD-S-3-010-415V / VFD-S-3-030-415V

    SPECIFICATIONS

    • AC Input Voltage Range : Three Phase: 450V
    • Frequency Range : 50Hz/60Hz
    • Control Mode : Space Vector PWM Based Scalar Control
    • Frequency Control Range : 0.1~400 Hz
    • Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
    • Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
    • Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
    • Ingress Protection : IP20
    • Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
    • Output Current :
      VFD-S-1-010-230V : 2.5A
      VFD-S-1-020-230V : 5.1A

    FEATURES

    • 4 Pre-set V/F mode & 1 user defined V/F Program
    • Input: Three phase 230V/415V, 50Hz/60Hz
    • Output power: 1 HP/0.75KW to 25HP/18.5KW
    • 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
    • Supports RS485 Modbus Communication protocol
    • Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
    • Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc
    Read more
  • SELEC VFD-SN-3-075-B-415V

    SPECIFICATIONS

    • AC Input Voltage Range : Three Phase : 415V
    • Frequency Range : 50Hz/60Hz
    • Control Mode : Space Vector PWM Based Scalar Control
    • Frequency Control Range : 0.1~400 Hz
    • Acc./Dec. Time : 0-3600 sec., 4 acceleration and deceleration time setting available
    • Overload Capacity : Over current, Over voltage, Under voltage, Over Temperature, Overload, Under current, System error.
    • Ingress Protection : IP20
    • Working Temperature : -10°C ~ +55°C , Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level

    FEATURES

    • 4 Pre-set V/F mode & 1 user defined V/F Program
    • Input: Three phase 230V/415V, 50Hz/60Hz
    • Output power: 1 HP/0.75KW to 25HP/18.5KW
    • 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
    • Supports RS485 Modbus Communication protocol
    • Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
    • Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc
    Read more
  • WACO Digital Earth Resistance Tester

    SPECIFICATIONS

    • Display : : 3½ Digits, LCD
    • Insulation Resistance Test : More than 25 Megohms at 500 V DC between electrical circuit & containing case
    • Dual Range : (a) 0 – 10 – 1000 OHM (b) 0 – 5 – 500 OHM

    FEATURES

    • Rugged ABS body
    • Easy to use hand held meter
    • Ni-cd Re- chargeable Cells
    • Confirms to ISS : 9223/1979
    • Four terminals {To measure earth resistance as well as specific
      soil resistivity}
    • Lo-Battery indication appears on Display indicating that the indicating the the cells (batteries) have gone down, which can be recharged by connecting to 230V, 50 Hz AC mains supply through charging cord provided with the instrument
    Read more
  • BEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC

    SPECIFICATIONS:

    • DC Voltage: 2000V
    • AC Voltage: 2000V
    • DC Current: 2000A
    • AC Current: 2000A
    • Resistance: 20 M ohms
    • Capacitance: 2000uF

     

    FEATURES

    • Display Mode: Display by LCD
    • Maximum Display: 1999
    • Digits: 3 ½ Digits
    • Maximum span of jaw: 55mm
    • Auto Range
    • Inrush Current
    • Resistance
    • Capacitance
    • Diode Test
    • Continuity Test
    • Data Hold
    • LED Testing
    • Back Light + Lamp Light
    • Auto negative polarity indication: displaying ‘-’
    • Auto Power Off
    • Battery: 9V

     

    Read more