SELEC TC303CX
Read moreSPECIFICATIONS
- Display Type : 7 Segment LED Dual Display
- Display Configuration : 3 Digits
- Type of Input : Thermocouple (J,K,T,R,S) / RTD (PT100)
- Resolution : Fixed 1°
- Accuracy : For TC (J, K, T) inputs: 0.25% of F.S. ± 1 °: For R & S inputs: 0.5% of F.S. ±2 (20min of warm up time) For RTD inputs: 0.1% of F.S ±1
- Control Output : RELAY/SSR
- Control mode : Auto Tune PID / ON-OFF
- Supply Voltage : 90 to 270V AC/DC
- Size : 96 x 96mm
- Mounting Type : Panel Mount
- Certification : CE
FEATURES
- 3 digit single White display
- TC/ RTD sensor input
- ON-OFF/Auto-tune PID control
- Single set point
- Relay / SSR control output
- Panel mount
- universal supply voltage
-
SELEC TC344CX
Read moreSPECIFICATIONS
- Display Type : 7 Segment LED Dual Display
- Display Configuration : 4 + 4 Digits LED dual display
- Type of Input : Thermocouple (J,K,T,R,S) / RTD (PT100)
- Resolution : 0.1/1° for TC/RTD (fixed 1° for R and S TC)
- Accuracy : For TC (J, K, T) inputs: 0.25% of F.S. ± 1 ° For R & S inputs: 0.5% of F.S. ±2 (20min of warm up time) For RTD inputs: 0.1% of F.S ±1
- Control Output : 5A Relay / 12V SSR
- Auxiliary Output : 5A Relay
- Control Mode : Auto Tune PID / ON-OFF
- Feature : Heat Cool PID , Dwell Timer
- Supply Voltage : 90 to 270V AC/DC
- Size : 96X96 mm
- Mounting Type : Panel Mount
FEATURES
- White + Green Bright dual display
- TC/ RTD sensor input
- Auto-tune PID/ ON-OFF control
- Dual set point
- Relay / SSR control output
- Auxiliary Relay output
- Heat-Cool PID and Dwell timer functions
- Panel mount
- universal supply voltage
-
SELEC TC544C
Read moreSPECIFICATIONS
- Display Type : 7 Segment LED Dual Display
- Display Configuration : 4+4 digits
- Accuracy : For TC (J, K, T) inputs: 0.25% of F.S. ± 1 °For R & S inputs: 0.5% of F.S. ±2(20min of warm up time) For RTD inputs: 0.1% of F.S ±1°
- Resolution : 0.1/1° for TC/RTD (fixed 1° for R and S TC)
- Control Output : RELAY or SSR.
- Auxiliary Output : RELAY
- Control Mode : Auto Tune / Selftune PID / ON-OFF
- Feature : Heat Cool PID , Dwell Timer, selectable 2nd Set point
- Supply Voltage : 90 to 270V AC / DC
- Size : 48 x 48mm
- Mounting Type : Panel mount
- Certification : CE
FEATURES
- 4 digit Dual display temperature controller
- (TC: J, K, T, R, S/ RTD: PT100) sensor input
- ON-OFF/Auto-tune PID control
- Dual set point
- 5A Relay/ 12V SSR control output
- Auxiliary 5A Relay output
- 48mm x 48 mm compact size
- Short depth
- Heat-Cool PID and Dwell timer functions
- Panel mount
- 90 to 270V AC/DC supply voltage
- CE, RoHS certified
-
SELEC VFD-L-1-005-230V / VFD-L-1-010-230V
Read moreSPECIFICATIONS
- AC Input Voltage Range : Single Phase: 230V
- Frequency Range : 50Hz/60Hz
- Control Mode : Scalar Control Based Space Vector PWM
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0.0 – 999.9 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
- Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
- Ingress Protection : IP20
- Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
- Output Current :
VFD-L-1-005-230V : 2.5A
VFD-L-1-010-230V : 5A
FEATURES
- 4 Pre-set V/F mode; 1 user defined V/F Program
- Input: Single phase 230V, 50Hz/60Hz
- Output: Three phase 230VAC, 0-400Hz
- Output Power: 0.5 HP/0.4KW & 1HP/0.75KW
- 4 (PNP/NPN) Inputs, 2 Analog Inputs(POT/0-10V;0-20mA/4-20mA), 1 Relay Output
- HMI with 5 keys, Potentiometer 4×7 segment with 4 LED display
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over Temperature, Overload and Under current, System error
- Suitable for application like Pumps, Fans, Conveyor, Food ; drink packaging machinery, Industrial washing machine and most general industries etc
-
SELEC VFD-S-1-010-230V / VFD-S-1-020-230V
Read moreSPECIFICATIONS
- AC Input Voltage Range : Single Phase: 230V
- Frequency Range : 50Hz/60Hz
- Control Mode : Scalar Control Based Space Vector PWM
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
- Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
- Ingress Protection : IP20
- Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
- Output Current :
VFD-S-1-010-230V : 5A
VFD-S-1-020-230V : 7A
FEATURES
- 4 Pre-set V/F; 1 user defined V/F Program
- Input: Single phase 230V, 50Hz/60Hz
- Output: Three phase 230VAC, 0-400Hz
- Output power: 0.5 HP/0.4KW TO 2HP/1.5 KW
- 5 (PNP/NPN) Inputs, 1 POT Input, 1 Analog Inputs(0-10V/0-20mA/4-20mA), 1 Relay Output, 1 Analog Output(0-10V/0-20mA); 1 Open collector output
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over Temperature, Overload and Under current, System error.
- Suitable for application like Pumps, Fans, Conveyor, Food; drink packaging machinery, Industrial washing machine and most general industries etc
-
SELEC VFD-S-3-010-415V / VFD-S-3-030-415V
Read moreSPECIFICATIONS
- AC Input Voltage Range : Three Phase: 450V
- Frequency Range : 50Hz/60Hz
- Control Mode : Space Vector PWM Based Scalar Control
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
- Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
- Ingress Protection : IP20
- Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
- Output Current :
VFD-S-1-010-230V : 2.5A
VFD-S-1-020-230V : 5.1A
FEATURES
- 4 Pre-set V/F mode & 1 user defined V/F Program
- Input: Three phase 230V/415V, 50Hz/60Hz
- Output power: 1 HP/0.75KW to 25HP/18.5KW
- 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
- Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc
-
SELEC VFD-SN-3-075-B-415V
Read moreSPECIFICATIONS
- AC Input Voltage Range : Three Phase : 415V
- Frequency Range : 50Hz/60Hz
- Control Mode : Space Vector PWM Based Scalar Control
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0-3600 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : Over current, Over voltage, Under voltage, Over Temperature, Overload, Under current, System error.
- Ingress Protection : IP20
- Working Temperature : -10°C ~ +55°C , Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
FEATURES
- 4 Pre-set V/F mode & 1 user defined V/F Program
- Input: Three phase 230V/415V, 50Hz/60Hz
- Output power: 1 HP/0.75KW to 25HP/18.5KW
- 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
- Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc
-
WACO Digital Earth Resistance Tester
Read moreSPECIFICATIONS
- Display : : 3½ Digits, LCD
- Insulation Resistance Test : More than 25 Megohms at 500 V DC between electrical circuit & containing case
- Dual Range : (a) 0 – 10 – 1000 OHM (b) 0 – 5 – 500 OHM
FEATURES
- Rugged ABS body
- Easy to use hand held meter
- Ni-cd Re- chargeable Cells
- Confirms to ISS : 9223/1979
- Four terminals {To measure earth resistance as well as specific
soil resistivity} - Lo-Battery indication appears on Display indicating that the indicating the the cells (batteries) have gone down, which can be recharged by connecting to 230V, 50 Hz AC mains supply through charging cord provided with the instrument
-
BEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC
Read moreSPECIFICATIONS:
- DC Voltage: 2000V
- AC Voltage: 2000V
- DC Current: 2000A
- AC Current: 2000A
- Resistance: 20 M ohms
- Capacitance: 2000uF
FEATURES
- Display Mode: Display by LCD
- Maximum Display: 1999
- Digits: 3 ½ Digits
- Maximum span of jaw: 55mm
- Auto Range
- Inrush Current
- Resistance
- Capacitance
- Diode Test
- Continuity Test
- Data Hold
- LED Testing
- Back Light + Lamp Light
- Auto negative polarity indication: displaying ‘-’
- Auto Power Off
- Battery: 9V