BEETECH B-6010 600A AC TRUE RMS CLAMPMETER
SPECIFICATIONS
- DC Voltage: 600V
Accuracy: ±(1% + 2 digits)
Resolution: 1V
Input Resistance: About 10MΩ
Max. Input Voltage: 600V DC or 600V RMS AC - AC Voltage: 600V
Accuracy: ±(1.2% + 10 digits)
Resolution: 1V
Input Resistance: About 10MΩ
Frequency range: 40Hz – 400Hz
Max. Input Voltage: 600V DC or 600V RMS AC - AC Current: 600A
Accuracy: ±(2.5% + 10 digits)
Resolution: 0.1A
Frequency Range: 50Hz ~ 60Hz
Max. Input Current: 120% of full scale, less than 60 seconds - Resistance: 40MΩ
Accuracy: ±(2% + 5 digits)
Resolution: 10kΩ
( Overload Protection: 600V DC or 600V RMS AC ) - Capacitance: 40mF
Accuracy: ±(4% + 3 digits )
Resolution: 10uF
( Overload Protection: 600V DC or 600V RMS AC ) - Diode test: Forward voltage drop value (open circuit voltage about 2.3V)
- Continuity test: Beeper sounds when resistance is less than 50 OHMS (open circuit voltage about 2.1V)
- Jaw size: 26 mm.
FEATURES
- Display: LCD
- 4000 Counts
- 3 ¾ Digits
- AC & DC Voltage
- AC Current
- True-RMS
- Resistance
- Capacitance
- Jaw Open Size: 26mm
- NCV
- Diode Test
- Continuity Buzzer
- Overload Protection
- Shock Proof Protection
- Input Impedence
- Backlight
- Torch
- Auto Power Off
- Low Battery Display
- DC Voltage: 600V
-
BEETECH B-6013 600A AC DUAL READING TRUE RMS DIGITAL CLAMPMETER
SPECIFICATIONS
- DC Voltage: 600V
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1V
Input Resistance: About 10MΩ
Max. Input Voltage: 600V DC - AC Voltage: 600V
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1V
Input Resistance: About 10MΩ
Frequency range: 40Hz – 400Hz -Response: True RMS
Max. Input Voltage: 600V AC (effective value) - AC Current: 600A
Accuracy: ±(3.0% + 6 digits)
Resolution: 0.1A
Frequency Range: 40Hz ~ 400Hz – Response: average value.
Max. Input Current: 600A DC
Max. Input Current: 600A AC - Resistance: 60MΩ
Accuracy: ±(1.2% + 3 digits)
Resolution: 0.1mΩ
( Overload Protection: 250V DC or 250VAC ) - Capacitance: 60mF
Accuracy: ±(4.5% + 5 digits )
Resolution: 0.01MF
( Overload Protection: 600V DC or 600V AC ) - Frequency: 10 mHz
Accuracy: ±(0.5% + 2 digits )
Resolution: 0.001 Mhz - Diode Test: Display approximate for ward voltage of diode:
Forward DC Current is about 1mA
Reverse DC voltage is about 3.3V - Continuity: Beeper sounds when resistance is less than 50 OHMS (open circuit voltage about 2.1V)
- Jaw size: 30 mm
FEATURES
- Display: LCD
- 6000 Counts
- 3 5/6 Digits
- AC & DC Voltage
- AC Current
- True-RMS
- Resistance
- Capacitance
- Frequency
- Temperature
- Jaw Open Size: 30mm
- NCV
- Diode Test
- Continuity Buzzer
- Overload Protection
- Shock Proof Protection
- Backlight
- Torch
- Auto Power Off
- Low Battery Display
- DC Voltage: 600V
-
BEETECH B-6015 PRO DIGITAL CLAMPMETER
SPECIFICATIONS
- AC VOLTAGE ( AVA )
Range : 600mV – 1000V
Resolution : 0.1mV – 1V
Accuracy : ±(1.0% ±3d) / ±(1.0% ±5d) - DCVOLTAGE ( DCV )
Range : 600mV – 1000V
Resolution : 0.1mV – 1V
Accuracy : ±(0.5% ±3d) / ±(0.8% ±5d - AC CURRENT ( ACA )
Range : 6A – 600A
Resolution : 0.001A – 0.1A
Accuracy : ±(2.5% ± 10 d) - RESISTANCE (Ω)
Range : 600Ω – 60MΩ
Resolution : 0.1Ω – 0.01MΩ
Accuracy : ±(1.0% ±5 d) / ±(1.0% ±2 d) / ±(1.2% ±8 d)
Overload Protection : 250VDC or 250VAC RMS - CAPACITANCE
Range : 60nF- 100mF
Resolution : 0.01nF – 0.1mF
Accuracy : ±(4.0% ±25 d) / ±(4.0% ±15 d) / ±(5.0% ±25 d)
Overload Protection : 250VDC or 250VAC RMS - FREQUENCY (Hz)
Range : 10Hz – 10MHz
Resolution : 0.01Hz – 0.01MHz
Accuracy : ±(0.5% ± 4 d
Overload Protection : 250VDC or 250VAC RMS - TEMPERATURE :
- Display 6000 counts
- LCD Backlight
- Data Hold
- NCV & LIVE Test
- Relativity Function
- TRMS
- Auto Ranging
- Bar display
- Range selection Auto
- Over Range Displays “OL”
- Input Polarity Displays negative“-”
- Conductor size 30mm
- Measuring Principal Double Integral A/D Conversion
- Sampling rate About 2 times / second
- Overload Protection
- Dimension 220(L) x 75(W) x 40(H)
- Weight 290g(including battery)
-
- AC VOLTAGE ( AVA )
-
BEETECH B-6018 SMART 600A AC DIGITAL CLAMPMETER
SPECIFICATIONS
- DC Voltage: 600V
Accuracy: ±(0.5% + 3 digits)
Resolution: 0.1V
In AUTO mode, input voltage ranges from 0.8V to 600V DC
Input voltage range in mV mode: 0.0mV ~ 600 mV DC - AC Voltage(T-RMS): 600V
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1V
In AUTO mode, input voltage ranges from 0.8V to 600V AC
Input Voltage range in mV mode: 0.0mV to 600mV AC
Frequency: 40Hz ~ 1000Hz - AC Current: 600A
Accuracy: ±(1.0% + 8 digits)
Resolution: 0.1A
Frequency Range: 40Hz ~ 400Hz – Response: average value
Min. Input Current: 0.8A AC
Max. Input Current: 600A AC - Resistance: 60MΩ
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1MΩ
Open Circuit voltage: approx.. 0.4V
Overload Protection: 600V DC or AC (valid value) - Capacitance: 60 mF
Accuracy: ±(2.5% + 20 digits)
Resolution: 0.001 mF
Overload Protection: 600V DC or AC Valid value - Frequency: 10Mhz
Accuracy: ±(2.5% + 20 digits)
Resolution: 0.001 Mhz
Measuring range: 1Hz ~ 10Mhz
Input signal pattern: >0.8V AC current (RMS) - Diode Test: Display approximate for ward voltage of diode
- Continuity: Built in Buzzer will be sounded if resistance is less than 50 Ohms
FEATURES
- Display: LCD
- 6000 Counts
- 3 5/6 Digits
- AC & DC Voltage
- AC Current
- True-RMS
- Resistance
- Capacitance
- Frequency
- Temperature
- Jaw Open Size: 30mm
- NCV
- Diode Test
- Continuity Buzzer
- Overload Protection
- Shock Proof Protection
- Input Impedence
- Backlight
- Torch
- Auto Power Off
- Low Battery Display
- DC Voltage: 600V
-
BEETECH B-6023 600V 600A AC/DC TRMS CLAMPMETER
SPECIFICATIONS
- DC Voltage: 600V
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1V
Response average input impedance: 10MΩ
Max. Input Voltage: 600V DC - AC Voltage: 600V
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1V
Input Resistance: 10MΩ
Frequency range: 40Hz – 400Hz
Response: True RM
Max. Input Voltage: 600V DC (effective value) - AC Current: 600A
Accuracy: ±(3.0% + 6 digits)
Resolution: 0.1A
Frequency Range: 40Hz ~ 400Hz Response: Avg. Value
Max. Input Current: 600A AC - AC Current: 600A
Accuracy: ±(2.5% + 8 digits)
Resolution: 0.1A
Max. Input Current: 600A DC - Resistance: 60MΩ
Accuracy: ±(1.2% + 3 digits)
Resolution: 0.1MΩ
Overload Protection: 250V DC or AC (valid value)
Open Circuit Voltage: Approx. 0.4V - Capacitance: 60mF
Accuracy: ±(4.5% + 5 digits)
Resolution: 0.01mF
Overload Protection: 250V DC or AC (valid value) - Frequency: 10Mhz
Accuracy: ±(0.5% + 2 digits)
Resolution: 0.001Mhz - Diode Test: 00.1V Display approximate for ward voltage of Diode.
• Forward DC Current is about 1mA.
• Reverse DC voltage is about 3.3V
• Overload Protection:250V DC or AC (valid value) - Continuity Test: 0.1Ω Built-in buzzer will be sounded if resistance is less than 50Ω
• Overload Protection:250V DC or AC (valid value)
FEATURES
- Display: LCD
- 6000 Counts
- 3 5/6 Digits
- AC & DC Voltage
- AC & DC Current
- True-RMS
- Resistance
- Capacitance
- Frequency
- Temperature
- Jaw Open Size: 30mm
- NCV
- Diode Test
- Continuity Buzzer
- Overload Protection
- Shock Proof Protection
- Input Impedence
- Backlight
- Torch
- Auto Power Off
- Low Battery Display
- DC Voltage: 600V
-
BEETECH B-6025 PRO DIGITAL CLAMPMETER
SPECIFICATIONS
- AC VOLTAGE ( ACV )
Range : 600mV – 1000V
Resolution : 0.1mV – 1V
Accuracy : ±(1.0% ±3d) / ±(1.0% ±5d) - DC VOLTAGE ( DCV )
Range : 600mV – 1000V
Resolution : 0.1mV – 1V
Accuracy : ±(0.5% ±3d) / ±(0.8% ±5d) - AC & DC CURRENT (ACA & DCA)
Range : 60A – 600A
Resolution : 0.01A – 0.1A
Accuracy : ±(2.5% ±10d) - RESISTANCE (Ω)
Range : 600Ω – 60MΩ
Resolution : 0.1Ω – 0.01MΩ
Accuracy : ±(1.0% ±5 d) / ±(1.0% ±2 d) / ±(1.2% ±8 d)
Overload Protection : 250VDC or 250VAC RMS - CAPACITANCE
Range : 10nF- 100mF
Resolution : 0.01nF – 0.1mF
Accuracy : ±(4.0% ±25 d) / ±(4.0% ±15 d) / ±(5.0% ±25 d)
Overload Protection : 250VDC or 250VAC RMS - FREQUENCY (Hz)
Range : 10Hz – 10MHz
Resolution : 0.01Hz – 0.01MHz
Accuracy : ±(0.5% ± 4 d
Overload Protection : 250VDC or 250VAC RMS - TEMPERATURE :
Range : -20°~ 1000°C / -4° ~1832°F
FEATURES
- Display 6000 counts
- Range Auto Ranging
- Continuity
- Input Polarity Displays negative“-”
- NCV & Live Test
- TRMS
- Auto Power Off
- Overload Protection
- Relativity Function
- Data hold
- Conductor size 30mm
- Jaw opening 34mm
- LCD Backlight Yes
- Bar display Yes
- Operating °C 0°C –40°C (<80% RH)
- Dimension 220(L) x 75(W) x 40(H)
- Weight 237g(including battery)
- Measuring principle Double Integral A/D
- Sampling rate About 2 times / second
NOTABLE FEATURES
(i) 1000V AC/DC Voltage
(ii) Inrush Current
(iii) Jaw opening from both the sides
(iv) Dual Range Display
(v) Double Mold Injection
(vi) Light and Sound NCV Indication
(vii) Quick Response Time
(viii) Overload Protection - AC VOLTAGE ( ACV )
-
BEETECH B-6028 600A 600V AC/DC SMART CLAMPMETER
SPECIFICATIONS
- DC Voltage: 600V
Accuracy: ±(0.5% + 3 digits)
Resolution: 0.1V
In AUTO mode, input voltage ranges from 0.8V to 600V DC
Input voltage range in mV mode: 0.0mV ~ 600 mV DC - AC Voltage: 600V
Accuracy: ±(0.8% + 10 digits)
Resolution: 1V
In AUTO mode, input voltage ranges from 0.8V to 600V AC
Input Voltage range in mV mode: 0.0mV to 600mV AC
Frequency: 40Hz ~ 1000Hz - AC Current: 600A
Accuracy: ±(2.5% + 30 digits)
Resolution: 0.1A
Frequency Range: 40Hz ~ 400Hz – Response: average value
Min. Input Current: 0.8A AC
Max. Input Current: 600A AC - DC Current: 600A
Accuracy: ±(2.5% + 30 digits)
Resolution: 0.1A
Frequency Range: 40Hz ~ 400Hz – Response: average value
Min. Input Current: 0.8A AC
Max. Input Current: 600A DC - Resistance: 60MΩ
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1mΩ
( Overload Protection: 600V DC or 600V AC ) - Capacitance: 60mF
Accuracy: ±(2.5% + 20 digits )
Resolution: 0.01MF
( Overload Protection: 600V DC or 600V AC ) - Frequency: 10 mHz
Accuracy: ±(1% + 5 digits )
Resolution: 0.001 Mhz - Diode Test: Display approximate for ward voltage of diode.
- Continuity: Built in Buzzer will be sounded if resistance is less than 50 Ohms.
- Temperature: -50°C ~ 1300°C
- Jaw size: 30 mm
FEATURES
- Display: LCD
- 6000 Counts
- 3 5/6 Digits
- AC & DC Voltage
- AC & DC Current
- True-RMS
- Resistance
- Capacitance
- Frequency
- Temperature
- Jaw Open Size: 30mm
- NCV
- Diode Test
- Continuity Buzzer
- Overload Protection
- Shock Proof Protection
- Input Impedence
- Backlight
- Torch
- Auto Power Off
- Low Battery Display
- DC Voltage: 600V
-
BEETECH B-6036 1000A AC Digital Clampmeter
SPECIFICATIONS
- DC Voltage :
Range : 600 mV To 1000V
Resolution : 0.1 mV To 1V
Accuracy : ±(0.5% + 3) ; ±(0.8% + 10)
Input Impendence: About 10MΩ - AC Voltage :
Range : 600 mV To 750V
Resolution : 0.1 mV To 1V
Accuracy : ±(0.8% + 5) ; ±(1.2% + 10)
Input Impendence: About 10MΩ - DC Current :
Range : 600µA To 6000µA
Resolution : 0.1µA To 0.001mA
Accuracy : ±(0.8% + 10) - AC Current :
Range : 600µA To 1000A
Resolution : 0.1µA To 1 A
Accuracy : ±(0.8% + 10d) - Resistance :
Range : 600Ω To 60MΩ
Resolution : 0.1Ω To 10kΩ
Accuracy : ±(1% + 25) - Frequency :
Range : 10 Hz To 20 mHz
Resolution : 0.01 Hz To 10 kHz
Accuracy : ± (0.1%+3) - Capacitance :
Range : 60nF To 6000uF
Resolution : 10pF To 1uF
Accuracy : ± (5%+10d) - Temperature : (-50~1000)°C / (0~1832)°F
FEATURES
- Display: LCD
- 6000 Counts
- 3 5/6 Digits
- AC & DC Voltage
- AC Current
- DC Current upto 6000uA
- Sampling rate 3 times
- Wide Jaw Size
- True-RMS
- Resistance
- Capacitance
- Frequency
- Temperature
- Auto Negative polarity indication: Displaying “-”
- Continuity Buzzer
- Duty Cycle
- Data Hold
- Diode Test
- Large LCD Display
- Low Battery
- Indication
- Auto Power Off
- DC Voltage :
-
BEETECH B-6040 AC/DC Digital Clampmeter
SPECIFICATIONS
- DC Voltage :
Range : 600 mV To 1000V
Resolution : 0.1 mV To 1V
Accuracy : ±(0.5% + 3) ; ±(0.8% + 10)
Input Impendence: About 10MΩ - AC Voltage :
Range : 600 mV To 750V
Resolution : 0.1 mV To 1V
Accuracy : ±(0.8% + 5) ; ±(1.2% + 10D)
Input Impendence: About 10MΩ - DC Current :
Range : 600µA To 1000A
Resolution : 0.1µA To 1A
Accuracy : ±(0.8% + 10d) - AC Current :
Range : 600µA To 1000A
Resolution : 0.1µA To 1 A
Accuracy : ±(0.8% + 10d) - Resistance :
Range : 600Ω To 60MΩ
Resolution : 0.1Ω To 10kΩ
Accuracy : ±(1% + 25d) - Frequency :
Range : 10 Hz To 20 mHz
Resolution : 0.01 Hz To 10 kHz
Accuracy : ± (0.1%+3d) - Capacitance :
Range : 60nF To 6000uF
Resolution : 10pF To 1uF
Accuracy : ± (5%+10d) - Temperature : (-50~1000)°C / (0~1832)°F
FEATURES
- Display: LCD
- 6000 Counts
- 3 5/6 Digits
- AC & DC Voltage
- AC & DC Current
- Sampling rate 3 times
- Wide Jaw Size
- True-RMS
- Resistance
- Capacitance
- Frequency
- Temperature
- Auto Negative polarity indication: Displaying “-”
- Continuity Buzzer
- Duty Cycle
- Data Hold
- Diode Test
- Large LCD Display
- Low Battery Indication
- Auto Power Off
- DC Voltage :
-
BEETECH B-6045 AC/DC CLAMPMETER
SPECIFICATIONS
- AC VOLTAGE ( ACV )
Range : 600mV – 1000V
Resolution : 0.1mV – 1V
Accuracy : ±(1.0% ±3d) / ±(1.0% ±5d) - DC VOLTAGE ( DCV )
Range : 600mV – 1000V
Resolution : 0.1mV – 1V
Accuracy : ±(0.5% ±3d) / ±(0.8% ±5d) - AC & DC CURRENT (ACA & DCA)
Range : 60A – 1000A
Resolution : 0.01A – 1A
Accuracy : ±(2.5% ±10d)
FrequencyResponse:TRMS50Hz–60Hz - RESISTANCE (Ω)
Range : 600Ω – 60MΩ
Resolution : 0.1Ω – 0.01MΩ
Accuracy : ±(1.0% ±5 d) / ±(1.0% ±2 d) / ±(1.2% ±8 d) - CAPACITANCE
Range : 10nF- 100mF
Resolution : 0.01nF – 0.1mF
Accuracy : ±(4.0% ±25 d) / ±(4.0% ±15 d) / ±(5.0% ±25 d)
Overload Protection : 250VDC or 250VAC RMS - FREQUENCY (Hz)
Range : 10Hz – 10MHz
Resolution : 0.01Hz – 0.01MHz
Accuracy : ±(0.5% ± 4 d
Overload Protection : 250VDC or 250VAC RMS - TEMPERATURE :
Range : -20°~ 1000°C / -4° ~1832°F
FEATURES
- Display 6000 counts
- Range Auto Ranging
- Continuity
- Input Polarity Displays negative“-”
- NCV & Live Test
- TRMS
- Auto Power Off
- Overload Protection
- Relativity Function
- Data hold
- Conductor size 42mm
- Jaw opening 42mm
- LCD Backlight Yes
- Bar display Yes
- Operating °C 0°C –40°C (<80% RH)
- Dimension 236(L) x 85(W) x 40(H)
- Weight 305g(including battery)
- Measuring principle Double Integral A/D
- Sampling rate About 2 times / second
NOTABLE FEATURES
(i) 1000V AC/DC Voltage
(ii) Inrush Current
(iii) Jaw opening from both the sides
(iv) Dual Range Display
(v) Double Mold Injection
(vi) Light and Sound NCV Indication
(vii) Quick Response Time
(viii) Overload Protection - AC VOLTAGE ( ACV )
-
BEETECH B-6046 1000A AC/DC Digital Clampmeter
SPECIFICATIONS
- DC Voltage :
Range : 400mV To 1000V
Resolution : 0.1 mV To 1V
Accuracy : ±(1.5% + 3d) ; ±(0.8% + 10)
Input Impendence: About 10MΩ - AC Voltage :
Range : 400 mV To 700V
Resolution : 0.1 mV To 1V
Accuracy : ±(1.2% + 5d) ; ±(1.5% + 3D)
Input Impendence: About 10MΩ - AC Amps :
Range : 40A To 1000A
Resolution : 10mA To 1A
Accuracy : ±(2% + 5d) - DC Amps :
Range : 40A To 1000A
Resolution : 10mA To 1 A
Accuracy : ±(2% + 10d) - Resistance :
Range : 400Ω To 40MΩ
Resolution : 0.1Ω To 10kΩ
Accuracy : ±(1.5% + 5d) - Frequency :
Range : 100 Hz To 40 mHz
Resolution : 0.01 Hz To 10 kHz
Accuracy : ± (0.5%+3d) - Temperature : (-50~1000)°C / (0~1832)°F
- Jaw Size : 52mm
FEATURES
- Display: LCD
- 4000 Counts
- 3 ¾ Digits
- AC & DC Voltage
- AC & DC Current
- DC Amps Auto Zero
- Max Jaw Size 52 MM
- True-RMS
- Inrush Current
- Resistance
- Capacitance
- Frequency
- Temperature
- Auto Negative polarity indication: Displaying “-”
- Continuity Buzzer
- Duty Cycle
- Data Hold
- Diode Test
- Large LCD Display
- Low Battery Indication
- Auto Power Off
- DC Voltage :
-
Beetech B-IR3 Digital Infrared Thermometer
SPECIFICATIONS
- Temperature Range : -50° ~ 580 ° C / – 58° ~ 1076 ° F
- Accuracy : -50°C ~ 0°C / -58°F ~ 32°F ; ±4°C / 7.2°F >0°C / 32°F ; ±2% or reading ±2°C / 3.6°F
- Emissivity : 0.1 ~ 1.0
- Optical Resolution : Distance : Spot = 13 : 1
- Response Time and Wavelength : <= 500 ms , 8 ~ 14 um
- Resolution : 0.1° C / 0.1°F
- Polarity Display : Auto display “-” indicates negative, positive with no indication
- Diode Laser : Output < 1mW, 630 ~ 670nm, class 2 (II)
- Auto Power Off : Auto shuts off after 20 seconds inactivity
- Temperature Conditions
Operation : 0 ~ 50°C/32~122°F
Storage : -20 ~ 70°C / -4 ~158°F - Humidity Conditions
Operation : 10 ~ 95% RH
Storage : < 80% RH - Dimensions / Weight : 155 X 100 X 44 mm / 172g
- Accessories : User manual, 9V Battery with Box packing
FEATURES
• Optical Resolution D:S = 13:1
• Emissivity : Adjustable 0.1 ~ 1.0
• Built in laser pointer .
• Max Min functions
• Over range indication
• Backlit LCD Display
• Data Hold
• Auto Power Off -
Beetech B-IR6 Digital Infrared Thermometer
SPECIFICATIONS
- Temperature Range : -50° ~ 850 ° C / – 58° ~ 1562 ° F
- Accuracy : -50°C ~ 0°C / -58°F ~ 32°F ; ±4°C / 7.2°F >0°C / 32°F ; ±2% or reading ±2°C / 3.6°F
- Emissivity : 0.1 ~ 1.0
- Optical Resolution : Distance : Spot = 13 : 1
- Response Time and Wavelength : <= 500 ms , 8 ~ 14 um
- Resolution : 0.1° C / 0.1°F
- Polarity Display : Auto display “-” indicates negative, positive with no indication
- Diode Laser : Output < 1mW, 630 ~ 670nm, class 2 (II)
- Auto Power Off : Auto shuts off after 20 seconds inactivity
- Temperature Conditions
Operation : 0 ~ 50°C/32~122°F
Storage : -20 ~ 70°C / -4 ~158°F - Humidity Conditions
Operation : 10 ~ 95% RH
Storage : < 80% RH - Dimensions / Weight : 155 X 100 X 44 mm / 172g
- Accessories : User manual, 9V Battery with Box packing
FEATURES
• Optical Resolution D:S = 13:1
• Emissivity : Adjustable 0.1 ~ 1.0
• Built in laser pointer .
• Max Min functions
• Over range indication
• Backlit LCD Display
• Data Hold
• Auto Power Off -
Beetech B-IR9 Digital Infrared Thermometer
SPECIFICATIONS
- Temperature Range : -50° ~ 1050 ° C / – 58° ~ 1922 ° F
- Accuracy : 50°C ~ 0°C / -58°F ~ 32°F ; ±4°C / 9°F >0°C / 32°F ; ±2% or reading ±2°C / 4°F
- Emissivity : 0.1 ~ 1.0
- Optical Resolution : Distance : Spot = 30 : 1
- Response Time and Wavelength : <= 250 ms , 8 ~ 14 um
- Resolution : 0.1° C / 0.1°F < 1000 ; 1°C / 1°F ≥ 1000
- Polarity Display : Auto display “-” indicates negative, positive with no indication
- Diode Laser : Output < 1mW, 630 ~ 670nm, class 2 (II)
- Auto Power Off : Auto shuts off after 20 seconds inactivity
- Temperature Conditions
Operation : 0 ~ 50°C/32~122°F
Storage : -20 ~ 60°C / -4 ~140°F - Humidity Conditions
Operation : 10 ~ 95% RH
Storage : < 80% RH - Dimensions / Weight : 155 X 100 X 44 mm / 172g
- Accessories : User manual, 9V Battery with Box packing
FEATURES
- Optical Resolution D:S = 30:1
- Emissivity : Adjustable 0.1 ~ 1.0
- Built in laser pointer .
- Max Min functions
- Over range indication
- Backlit LCD Display
- Data Hold
- Auto Power Off
-
BEETECH B-M2 Digital Moisture Meter
SPECIFICATIONS
- Electrode Length : 10 mm
- Electrodes : Replaceable
- Moisture Range : Wood : 5 ~ 70% RH , Building Material : 0.1~2.4% RH
- Temperature Range : -20 ~ 70°C / -4 ~ 122°F
- Moisture Accuracy –
Wood : 5 ~ 30% : ±1%
30 ~ 60% : ±2%
60 ~ 70% : ±4%
Other: ±5% - Temperature Accuracy : -20 ~ 70°C / -4 ~ 158°F : ±1.5°C / 2.7°F
- Auto Power Off : After 120 seconds of inactivity
- Operating Ambient Temperature : 0 ~ 50°C/32~122°F
- Operating Ambient Humidity : 0 ~ 85% RH
- Dimensions : 163 X 62 X 30 mm
- Weight : 153 g
- Accessories : User Manual , 9V Battery, Pouch with Box packing
FEATURES
- Big LCD display with backlight.
- Replaceable electrode pins .
- Various materials measurement.
- Analog bar and digital display values at same time.
- Selectable measurement for wood or other building material.
- Simultaneous measurement of moisture & temperature
-
BEETECH BAT-6000 BREATH ALCOHOL ANALYSER
SPECIFICATIONS
- Detection range : 0.00 – 200 mg/100mL
- Alarming Level : 50 mg/100mL
- Accuracy : ± 10% F.S
FEATURES
- Display Mode: LCD display with light blue
backlit - Advanced flat surfaced alcohol sensor
- SMD assembling and stable performance
- Direct testing process LCD indication
- Portable and aesthetically pleasing
design - Audio warning beyond pre-set limit
- Sensor fault self checking
- Low power consumption
- Low voltage indication
- Power supply: 4.5V (3xAAA) battery
- Working current: ≤ 120mA
- Weight: ≈ 64g (battery excluded)
- Operating environment: -10˚C ~ 50˚C, RH ≤ 95% no dews
- Dimensions: 103(L) x 65(W) x 27mm(H)
- Battery expectancy time: ≥ 200 times