DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
Frequency Range : 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Accuracy : ±0.1 % rdg. ±1 dgt
Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt.
Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
Mass : 390 g (13.8 oz) (including batteries and holster)
Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
Prevents short-circuit accidents with a fast-blow fuse and current-limiting resistor (DT4255)
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
Broad -25°C to 65°C (-13°F to 149°F) operating temperature range (DT4254, DT4255)
Voltage detection function (DT4254, DT4255)
Dual display lets you check voltage and frequency simultaneously
DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.3 % rdg. ±3 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
DC Current range : 60.00 mA to 10.00 A, 4 ranges,
Accuracy : ±0.9 % rdg. ±3 dgt.
AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz)
Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt.
AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Voltage Detection : Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
Frequency Range : 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current)
Accuracy : ±0.1 % rdg. ±1 dgt
Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt.
Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode Test : Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
Other Functions : Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D
Mass : 390 g (13.8 oz) (including batteries and holster)
Including Accessories : Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
FEATURES
±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
USB communications function supports PC measurements (optional)
Broad -25°C to 65°C (-13°F to 149°F) operating temperature range
Dual display lets you check voltage and frequency simultaneously
DC Voltage range : 600.0 mV to 1000 V , 5 ranges
Accuracy : ±0.15 % rdg. ±2 dgt.
AC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz
Accuracy : 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3 Or less)
AC+ DC Voltage range : 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz
Accuracy : DC, 40 Hz – 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
DC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : ±0.5 % rdg. ±3 dgt.
AC Current range : 600.0 mA to 10.00 A, 3 ranges,
Accuracy : 40 – 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3 or less)
Resistance range : 600.0 Ω to 60.00 MΩ, 6 ranges,
Basic accuracy: ±0.7 % rdg. ±3 dgt.
AC Current Range ( use with Clamp on probes ) : 10.00 A to 1000 A, 7 ranges,
Basic accuracy 40 Hz – 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less)
Capacitance Range : 1.000 μF to 10.00 mF, 5 ranges
Accuracy : ±1.9 % rdg. ±5 dgt.
Continuity check : Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode Test : Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V
Voltage frequency range : 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Current frequency range : 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Display : Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display Refresh Rate : 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Dimensions : 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D
Mass : 480 g (16.9 oz.) (with test leads holder and batteries)
Including Accessories : Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1
FEATURES
Helping personnel analyze issues in the field
Stop worrying about losing test lead caps
Boost work efficiency with digitalization (Excel® Direct Input Function)
Excellent dust and water resistance (compliant with the IP54 international standard)
Ensuring safety by preventing erroneous test lead insertion (terminal shutters)
Harmonic levels : [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Other Functions : Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)