  • Fluke 376 True RMS AC/DC Clamp Meter with iFlex®

    SPECIFICATIONS

    • AC Current via Jaw
      Range : 999.9A
      Resolution : 0.1A
      Accuracy : 2% ± 5 digits (10-100 Hz) ; 2.5% ± 5 digits (100-500 Hz)
    • AC Current via Flexible Current Probe
      Range : 2500A
      Resolution : 0.1 A (≤ 999.9 A) ; 1 A (≤ 2500 A)
      Accuracy : 3% ±5 digits (5 – 500 Hz)
    • DC Current
      Range : 999.9A
      Resolution : 0.1 A
      Accuracy : 2% ±5 digits
    • AC Voltage
      Range : 1000V
      Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
      Accuracy : 1.5% ± 5 digits (20 – 500 Hz)
    • DC Voltage
      Range : 1000V
      Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
      Accuracy : 1% ±5 digits
    • Frequency Via Jaw
      Range : 5.0 – 500.0 Hz
      Resolution : 0.1 Hz
      Accuracy : 0.5% ± 5 digits
    • Frequency via Flexible Current Probe
      Range : 5.0 – 500.0 Hz
      Resolution : 0.1 Hz
      Accuracy : 0.5% ± 5 digits
    • Resistance
      Range : 60 kΩ
      Resolution : 0.1 Ω (≤ 600 Ω) ; 1 Ω (≤ 6000 Ω) ; 10 Ω (≤ 60 kΩ)
      Accuracy : 1% ± 5 digits
    • Capacitance
      Range : 1000 μF
      Resolution : 0.1 μF (≤ 100 μF) ; 1 μ F (≤ 1000 μF)
      Accuracy : 1% ± 4 digits
    • Jaw Opening : 34mm
    • Flexible Current Probe Diameter : 7.5mm
    • Flexible Current Probe Cable Length (head to electronics connector) : 1.8M
    • Operating Temperature : 14°F to 122°F (-10 °C to 50 °C)
    • Storage Temperature : -40 °F to 140 °F (-40 °C to 60 °C)
    • Size : 246 mm x 83 m x 43 mm
    • Weight : 388g

    FEATURES

    • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
    • CAT IV 600 V, CAT III 1000 V
    • True RMS AC voltage and current for accurate measurements on non-linear signals
    • Min, max, average and Inrush recording to capture variations automatically
    • Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
    • Proprietary Inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
    • Ergonomic design fits in your hand and can be used while wearing protective equipment
    • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
    • Three-year warranty
    • Soft Carrying Case
    Read more
  • Fluke 393 Solar Clamp Meter CAT III 1500 V

    SPECIFICATIONS 

    • AC Current via Jaw
      Range : 999.9A
      Resolution : 0.1A
      Accuracy : 2% ± 5 digits (10-100 Hz) ; 2.5% ± 5 digits (100-500 Hz)
    • AC Current via Flexible Current Probe
      Range : 2500A
      Resolution : 0.1 A (≤ 999.9 A) ; 1 A (≤ 2500 A)
      Accuracy : 3 % RD + 5 digits (10 Hz to 500 Hz)
    • DC Current
      Range : 999.9A
      Resolution : 0.1 A
      Accuracy : 2% ±5 digits
    • AC Voltage
      Range : 600V to 1000V
      Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
      Accuracy : 1 % RD + 5 digits (20 Hz to 500 Hz)
    • DC Voltage
      Range : 600V to 1500V
      Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1500 V)
      Accuracy : 1% ±5 digits
    • Frequency Via Jaw
      Range : 5.0 – 500.0 Hz
      Resolution : 0.1 Hz
      Accuracy : 0.5% ± 5 digits
    • Frequency via Flexible Current Probe
      Range : 5.0 – 500.0 Hz
      Resolution : 0.1 Hz
      Accuracy : 0.5% ± 5 digits
    • Resistance
      Range : 600.0 Ω ; 6000 Ω ; 60 kΩ
      Resolution : 0.1 Ω (≤ 600 Ω) ; 1 Ω (≤ 6000 Ω) ; 10 Ω (≤ 60 kΩ)
      Accuracy : 1% ± 5 digits
    • Capacitance
      Range : 100 μF ; 1000 μF
      Resolution : 0.1 μF (≤ 100 μF) ; 1 μ F (≤ 1000 μF)
      Accuracy : 1% ± 5 digits
    • Jaw Opening : 34mm
    • Flexible Current Probe Diameter : 7.5mm
    • Flexible Current Probe Cable Length (head to electronics connector) : 1.8M
    • Operating Temperature : 14°F to 122°F (-10 °C to 50 °C)
    • Storage Temperature : -40 °F to 140 °F (-40 °C to 60 °C)
    • Size : 281 mm x 84 mm x 49 mm
    • Weight : 520g

    FEATURES

    • Measure safely with CAT III 1500 V rated clamp meter
    • Thin jaw for access to cables in crowded combiner boxes
    • Sturdy IP54 rated for outdoor use and solar installation
    • Work efficiently with dc power measurement, audio polarity and visual continuity
    Read more
  • Fluke 59 Max Infrared Thermometer

    SPECIFICATIONS 

    • Temperature Range : -30°C to 350°C (-22°F to 662°F)
    • Response Time (95%) : < 500 ms (95% of reading)
    • Spectral Response : 8 mm to 14 mm
    • Emissivity : 0.10 to 1.00
    • Distance to Spot Ratio : 8:1 (calculated at 90% energy)
    • Display Resolution : 0.1°C (0.2°F)
    • Operating Temperature : 0°C to 50°C (32°F to 122°F)
    • Storage Temperature : -20°C to +60°C (-4°F to 140°F), (without battery)
    • Operating Humidity : 10% to 90% RH non-condensing @ 30°C (86°F)
    • Operating Altitude : 2000 meters above mean sea level
    • Storage Altitude : 12,000 meters above mean sea level

    FEATURES

    • Laser targeting for use from -30 °C to 350 °C (-22 °F to 662 °F)
    • Small, rugged design easily fits your hand and your toolbox
    • Easy-to-read, backlit LCD screen
    Read more
  • Fluke 59 MAX+ Infrared Thermometer

    SPECIFICATIONS

    • Temperature Range : -30°C to 500°C (-22°F to 932°F)
    • Response Time (95%) : < 500 ms (95% of reading)
    • Spectral Response : 8 mm to 14 mm
    • Emissivity : 0.10 to 1.00
    • Distance to Spot Ratio : 10:1 (calculated at 90% energy)
    • Display Resolution : 0.1°C (0.2°F)
    • Operating Temperature : 0°C to 50°C (32°F to 122°F)
    • Storage Temperature : -20°C to +60°C (-4°F to 140°F), (without battery)
    • Operating Humidity : 10% to 90% RH non-condensing @ 30°C (86°F)
    • Operating Altitude : 2000 meters above mean sea level
    • Storage Altitude : 12,000 meters above mean sea level

    FEATURES

    • Easy to handle infrared thermometer with precise laser targeting and 10:1 distance to spot ratio
    • Measures temperatures from -30°C to 500°C (-22°F to 932°F)
    • Provides IP40 rating for extra protection
    • Presents a large, backlit LCD display for easy viewing
    • Features a small, lightweight design that fits easily fits into your tool bag
    Read more
  • Fluke 59 Mini Infrared Thermometer

    SPECIFICATIONS 

    • Temperature Range : – 18°C to 275°C (0°F to 525°F)
    • Response Time (95%) : < 500 ms
    • Spectral Response :  6.5 – 18 um thermopile detector
    • Emissivity : 0.95 Pre Set
    • Distance to Spot Ratio : 8:1 (calculated at 90% energy)
    • Display Resolution : 0.2°C (0.5°F)
    • Storage Temperature : -20°C to +65°C (-4°F to 150°F), (without battery)
    • Operating Humidity : 10% – 90% RH non-condensing @ up to 30°C(86°F)

    FEATURES

    • Small in size easily fit in your pocket
    • Laser targeting for fast, precise measurements
    • Backlit display for easy reading in dark work areas
    • 8:1 distance to spot ratios measures a 10 cm spot from 10 meters to target just what you want
    • ± 2% basic accuracy gives you readings you can trust
    Read more
  • FLUKE 62 MAX Infrared Thermometer

    SPECIFICATIONS 

    • Temperature Range : -30°C to 500°C (-22°F to 932°F)
    • Response Time (95%) : < 500 ms (95% of reading)
    • Spectral Response : 8 mm to 14 mm
    • Emissivity : 0.10 to 1.00
    • Distance to Spot Ratio : 10:1 (calculated at 90% energy)
    • Display Resolution : 0.1°C (0.2°F)
    • Operating Temperature : 0°C to 50°C (32°F to 122°F)
    • Storage Temperature : -20°C to +60°C (-4°F to 140°F), (without battery)
    • Operating Humidity : 10% to 90% RH non-condensing @ 30°C (86°F)
    • Operating Altitude : 2000 meters above mean sea level
    • Storage Altitude : 12,000 meters above mean sea level
    • Safety : IEC 61010-1: Pollution degree 2 ; IEC 60825-1: Class 2

    FEATURES

    • Highly accurate infrared thermometer for measuring temperatures from -30°C to 500°C (-22°F to 932°F) accurate to +1.5°C or +1.5% of reading (whichever is greater)
    • Provides a 10:1 Distance to spot ratio
    • Offers single laser targeting for accurate and repeatable measurements
    • Features IP54 rating against dust and moisture
    Read more
  • FLUKE 925 VANE ANEMOMETER

    SPECIFICATIONS

    • Wind Speed Measurement
      m/s : 0.40 to 25.00 m/s
      ft/m : 80 to 4900 ft/m
    • Air Flow Measurement
      Cubic meter/ second : 0.01 to 99.99 m3/s
      Cubic foot/minute : 1 to 9999 ft3/m
    • Wind Temperature Measurement
      Wind Temperature : 0°C to 50°C
    • Display : Dual-screen 4-digit (9999 points) LCD screen
    • Measurement Unit
      Wind speed: ft/m; m/s
      Air flow: CMS (m3/s) and CFM (ft3/m) (cubic foot/minute)
      Wind temperature: °C and °F
    • Data Holding : Lock the displayed readings
    • Sensor
      Wind speed/air flow sensor: conventional angular vane arm, lubricating ball bearing
      Wind temperature sensor: precision thermistor
      Minimum/maximum value storage, recording and viewing the minimum reading and maximum reading
    • Auto Power Off : Enter the sleep mode after 20 minutes (can be disabled) to save power
    • Battery Life : 100 Hours
    • Weight : 363 g, including the battery and sensor
    • Dimensions: 181 × 71 × 38 mm
    • Sensor head diameter : 70 mm

    FEATURES

    • Ability to measure wind speed in feet per minute or meters per second
    • Data capture using one button and the ability to average multiple readings
    • Min and Max alarm setting to alert the user when limits have been met
    • Durable over mold housing to protect the unit from drops
    • 1 M extension of sensor from display to ensure air flow is captured in hard to reach location
    Read more
  • Fluke 941 Light Meter

    SPECIFICATIONS 

    • Range : 20, 200, 2000, 20000, 200000 Lux ; 20, 200, 2000, 20000FC (footcandle)
    • Sampling Rate : 2.5 times/second for the digital display
    • Display : 3½ digit 1999-point LCD screen
    • Sensor : Silicon photoelectric diode and optical filter
    • Environment : For indoor use
    • Dimension : 130 × 63 × 38 mm
      Dimension Of Sensor : 80 × 55 × 29 mm
    • Weight : 220 g (including the battery)

    FEATURES

    • Measure in lux or foot-candles, with one button to switch between display options
    • Measuring range up to 20,000 lux or foot candles
    • Data hold to freeze reading on the digital display
    • Min/max ability to show high and low readings
    • Auto power off to save battery life
    • Includes protective sensor cap
    Read more
  • Fluke 945 Sound Meter

    SPECIFICATIONS

    • Environmental Noise
      Range : 30 to 130 dB
      Resolution : 0.1 dB
      Accuracy : ±1.5 dB (ref 94dB@1KHZ)
    • Mechanical Noise :
      Range : 30 to 130 dB
      Resolution : 0.1 dB
      Accuracy : ±1.5 dB (ref 94dB@1KHZ)
    • Display : 0.1 dB steps on 4-digit LCD screen
    • Frequency Response : From 31.5 Hz to 8 kHz
    • Dimensions : 200 x 56 32 mm
    • Safety Standard : CE, designed to meet IEC651 Type2, ANSI S1.4 Type 2

    FEATURES

    • Max/Min
    • Frequency weighting ranges: A, C
    • Auto power off
    • Auto ranging
    • Backlit display
    Read more
  • Fluke VT06 Visual IR Thermometer

    SPECIFICATIONS

    • Infrared resolution : 120×90
    • IR frequency band : 7.5~14 μm(long wave)
    • Frame Rate : 9 Hz
    • Thermal sensitivity/NETD : <60 mk
    • Field of view (H x V) : 50° x 37.5°
    • Spatial resolution : 7.6 mrad
    • Focus system : Focus free
    • Minimum focusing distance : 0.5 m (19.7 in)
    • Temperature Range : -20 °C to 400 °C ; [-4 °F to 752 °F] (not specified for below -10 °C)
    • Temperature Accuracy : ±2°C or 2% @ 23°C±5°C, whichever is greater
    • Emissivity : Adjustable
    • Operating temperature : -10 °C to 50 °C
    • Storage temperature : -40 °C to 70 °C
    • Operating altitude : 2000 m (1.24 mi)
    • Storage Altitude : 12000 m (7.5 mi)
    • Display : 6.096 cm (2.4-inch) LCD
    • Size : 20.4 cm x 6.6 cm x 7.6 cm
    • Weight : 0.36Kg
    • Safety Standard : IEC 61010-1: Pollution Degree 2

    FEATURES 

    • 120 x 90 resolution for more details
    • Wide temperature range, -20°C to 400°C
    • IP65 rated for dust and water proof, 2m drop test, suitable for harsh industrial environments
    • Quickly locate the measured target with built-in laser pointer
    • 2 hours charging time, 8 hours battery life
    • Single-level menu interface, Open-and-View
    Read more
  • Fluke VT08 Visual IR thermometer

    SPECIFICATIONS

    • Infrared resolution : 120×90
    • IR frequency band : 7.5~14 μm(long wave)
    • Frame Rate : 9 Hz
    • Thermal sensitivity/NETD : <60 mk
    • Field of view (H x V) : 50° x 37.5°
    • Spatial resolution : 7.6 mrad
    • Focus system : Focus free
    • Minimum focusing distance : 0.5 m (19.7 in)
    • Visible resolution : 320×240
    • Visible FOV (H x V) : 53° x 41°
    • Temperature Range : -20 °C to 400 °C ; [-4 °F to 752 °F] (not specified for below -10 °C)
    • Temperature Accuracy : ±2°C or 2% @ 23°C±5°C, whichever is greater
    • Emissivity : Adjustable
    • Operating temperature : -10 °C to 50 °C
    • Storage temperature : -40 °C to 70 °C
    • Operating altitude : 2000 m (1.24 mi)
    • Storage Altitude : 12000 m (7.5 mi)
    • Display : 6.096 cm (2.4-inch) LCD
    • Size : 20.4 cm x 6.6 cm x 7.6 cm
    • Weight : 0.36Kg
    • Safety Standard : IEC 61010-1: Pollution Degree 2

    FEATURES 

    • 120 x 90 resolution for more details
    • Wide temperature range, -20 °C to 400 °C
    • Blends a visual image with infrared heat image overlay in real-time to clearly distinguish the measured target
    • IP65 rated for dust and water proof, 2m drop test, suitable for harsh industrial environments
    • Quickly locate the measured target with built-in laser pointer
    • 2 hours charging time, 5 hours battery life
    • Single-level menu interface, Open-and-View
    Read more
  • HANNA HI98107 pHep Waterproof Pocket pH Tester with 0.1 pH Resolution

    SPECIFICATIONS 

    • pH Range : 0.0 to 14.0 pH
    • pH Resolution : 0.1 pH
    • pH Accuracy : ±0.1 pH
    • pH Calibration : Automatic, one or two points
    • pH Temperature Compensation : Automatic, 0 to 50 oC (32 to 122°F)
    • Temperature Range : 0 to 50 oC (32.0 to 122.0oF)
    • Temperature Resolution : 0.1 oC / 0.1 °F
    • Temperature Accuracy : ±0.5 oC / ±1.0 °F
    • Automatic Shut-Off : 8 minutes, 60 minutes, or disabled
    • Dimensions : 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
    • Weight : 65 g (2.3 oz.) without battery

    FEATURES

    • Slim, ergonomic design that fits comfortably in the hand or pocket
    • Automatic temperature compensation, displays temperature in °C or °F
    • Automatic calibration with standard buffers (pH 4.01, 7.01, and 10.01)
    • Stability indicator confirms the reading has stabilized
    • Automatic shut-off with three user controlled settings to conserve battery life
    • Battery Error Prevention System (BEPS)
    • An exposed temperature sensor along with an extractable cloth junction ensures a fast and stable temperature compensated measurement
    • Only two buttons for meter operation. One for on/off and one for calibration.
    Read more
  • HANNA HI98301 DiST1, waterproof TDS tester with ATC, 1999 ppm (mg/L)

    SPECIFICATIONS

    • TDS Range : 0 to 2000 ppm (mg/L)
    • TDS Resolution : 1 ppm (mg/L)
    • TDS Accuracy : ±2% F.S.
    • TDS Calibration : automatic, one point at 1382 ppm
    • EC/TDS Temperature Compensation : automatic from 0 to 50°C (32 to 122°F)
    • Temperature Correction Coefficient : 1.9%/°C
    • EC to TDS Conversion Factor : 0.5
    • Temperature Range : 0.0 to 50.0°C (32.0 to 122.0°F)
    • Temperature Resolution : 0.1°C (0.1°F)
    • Temperature Accuracy : ±0.5°C (±1°F)
    • Automatic Shut-Off : 8 minutes, 60 minutes, or disabled
    • Environment : 0 to 50°C (32 to 122°F); RH 100%
    • Dimensions : 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
    • Weight : 68 g (2.4 oz.) without battery

    FEATURES 

    • Slim, Ergonomic Design
      With rounded edges and a case that is only 17 mm (0.7”) thick, the HI98301 is thin and fits comfortably in the hand or pocket.
    • Large Multi-level LCD
      The LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both the pH and temperature simultaneously.
    • Two-button Operation
      One for ON/OFF, the other for calibration.
    • Exposed Temperature Sensor
      Exposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either oC or oF.
    • Graphite Sensor
      Reduces polarization effects and does not oxidize resulting in a reliable and accurate reading.
    • Automatic Calibration
      Automatic calibration at 1382 ppm (mg/L) with a single push of a button.
    • Stability Indicator
      A clock tag stability indicator will disappear to alert the user when the reading is stable.
    • Automatic Shut-off
      User-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.
    • Low Battery Indicator
      Low battery indicator that is displayed when less than 10% battery life is remaining.
    • Battery % Level at Startup
      At start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed
    Read more
  • HIOKI AC CLAMP METER 3280-10F

    SPECIFICATIONS

    • AC Current range : 41.99 to 1000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy: ±1.5 % rdg. ±5 dgt.
    • DC Voltage range : 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.
    • AC Voltage range : 4.199 V to 600 V, 4 ranges (45 to 500 Hz, Average rectified), Basic accuracy: ±1.8 % rdg. ±7 dgt.\
    • Resistance range : 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.
    • Other functions : Continuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter
    • Display : LCD, max. 4199 dgt., Display refresh rate: 400 ms
    • Environmental protection : IP40 dustproof and waterproof
    • Power supply : Coin type lithium battery (CR2032) ×1, Continuous use 120 hours
    • Core jaw dia. : φ 33 mm (1.30 in)
    • Dimensions and mass : 57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz)

    FEATURES

    • Measure the fundamental waveform component using the average rectified method
    • Expanded -25°C to 65°C operating temperature range
    • Connect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires
    • Drop proof design withstands drop from a height of 1 meter
    Read more
  • HIOKI AC/DC CLAMP METER CM4371-50

    SPECIFICATIONS

    • DC Current range : 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
    • AC Current range :  20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A
    • Crest factor : 20.00 A range: 7.5 ; 600.0 A range: 3 or less
    • DC+AC Current range : 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
    • DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
    • AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
    • DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
    • Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
    • Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
    • Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
    • Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
    • Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
    • Dustproof, waterproof : IP54 (Storage or measurement of current of an insulated conductor)
    • Core jaw diameter : φ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in)
    • Power supply : LR03 Alkaline battery ×2 ; Continuous use: 40 hr (without Z3210 installed), 20 hr. (with Z3210 installed and using wireless communications) ; Other conditions: 10 A AC measurement, backlight off, 23°C reference value

    FEATURES

    • CAT IV 600 V, CAT III 1000 V When using the P2000: CAT III 2000 V, CAT IV 1000 V
    • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
    • Simultaneously measure inrush current in RMS and crest values
    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file
    • Harmonic analysis from 1st to 30th order with our free app GENNECT Cross
    • Automatic AC/DC function helps boost work efficiency
    Read more
  • HIOKI AC/DC CLAMP METER CM4373-50

    SPECIFICATIONS 

    • DC Current Range : 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)
    • AC Current Range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)
    • Crest factor : 600.0 A range: 3 or less ; 2000 A range: 2.84 or less
    • DC+AC Current range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)
    • DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
    • AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
    • DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
    • Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
    • Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
    • Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
    • Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
    • Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz

    FEATURES

    • CAT IV 600 V, CAT III 1000 V
      When using P2000: CAT III 2000 V, CAT IV 1000 V
    • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
    • Simultaneously measure inrush current in RMS and crest values
    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
    • Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
    • Automatic AC/DC function helps boost work efficiency
    Read more