Fluke 376 True RMS AC/DC Clamp Meter with iFlex®
SPECIFICATIONS
- AC Current via Jaw
Range : 999.9A
Resolution : 0.1A
Accuracy : 2% ± 5 digits (10-100 Hz) ; 2.5% ± 5 digits (100-500 Hz) - AC Current via Flexible Current Probe
Range : 2500A
Resolution : 0.1 A (≤ 999.9 A) ; 1 A (≤ 2500 A)
Accuracy : 3% ±5 digits (5 – 500 Hz) - DC Current
Range : 999.9A
Resolution : 0.1 A
Accuracy : 2% ±5 digits - AC Voltage
Range : 1000V
Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
Accuracy : 1.5% ± 5 digits (20 – 500 Hz) - DC Voltage
Range : 1000V
Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
Accuracy : 1% ±5 digits - Frequency Via Jaw
Range : 5.0 – 500.0 Hz
Resolution : 0.1 Hz
Accuracy : 0.5% ± 5 digits - Frequency via Flexible Current Probe
Range : 5.0 – 500.0 Hz
Resolution : 0.1 Hz
Accuracy : 0.5% ± 5 digits - Resistance
Range : 60 kΩ
Resolution : 0.1 Ω (≤ 600 Ω) ; 1 Ω (≤ 6000 Ω) ; 10 Ω (≤ 60 kΩ)
Accuracy : 1% ± 5 digits - Capacitance
Range : 1000 μF
Resolution : 0.1 μF (≤ 100 μF) ; 1 μ F (≤ 1000 μF)
Accuracy : 1% ± 4 digits - Jaw Opening : 34mm
- Flexible Current Probe Diameter : 7.5mm
- Flexible Current Probe Cable Length (head to electronics connector) : 1.8M
- Operating Temperature : 14°F to 122°F (-10 °C to 50 °C)
- Storage Temperature : -40 °F to 140 °F (-40 °C to 60 °C)
- Size : 246 mm x 83 m x 43 mm
- Weight : 388g
FEATURES
- iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
- CAT IV 600 V, CAT III 1000 V
- True RMS AC voltage and current for accurate measurements on non-linear signals
- Min, max, average and Inrush recording to capture variations automatically
- Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary Inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Three-year warranty
- Soft Carrying Case
- AC Current via Jaw
-
Fluke 393 Solar Clamp Meter CAT III 1500 V
SPECIFICATIONS
- AC Current via Jaw
Range : 999.9A
Resolution : 0.1A
Accuracy : 2% ± 5 digits (10-100 Hz) ; 2.5% ± 5 digits (100-500 Hz) - AC Current via Flexible Current Probe
Range : 2500A
Resolution : 0.1 A (≤ 999.9 A) ; 1 A (≤ 2500 A)
Accuracy : 3 % RD + 5 digits (10 Hz to 500 Hz) - DC Current
Range : 999.9A
Resolution : 0.1 A
Accuracy : 2% ±5 digits - AC Voltage
Range : 600V to 1000V
Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
Accuracy : 1 % RD + 5 digits (20 Hz to 500 Hz) - DC Voltage
Range : 600V to 1500V
Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1500 V)
Accuracy : 1% ±5 digits - Frequency Via Jaw
Range : 5.0 – 500.0 Hz
Resolution : 0.1 Hz
Accuracy : 0.5% ± 5 digits - Frequency via Flexible Current Probe
Range : 5.0 – 500.0 Hz
Resolution : 0.1 Hz
Accuracy : 0.5% ± 5 digits - Resistance
Range : 600.0 Ω ; 6000 Ω ; 60 kΩ
Resolution : 0.1 Ω (≤ 600 Ω) ; 1 Ω (≤ 6000 Ω) ; 10 Ω (≤ 60 kΩ)
Accuracy : 1% ± 5 digits - Capacitance
Range : 100 μF ; 1000 μF
Resolution : 0.1 μF (≤ 100 μF) ; 1 μ F (≤ 1000 μF)
Accuracy : 1% ± 5 digits - Jaw Opening : 34mm
- Flexible Current Probe Diameter : 7.5mm
- Flexible Current Probe Cable Length (head to electronics connector) : 1.8M
- Operating Temperature : 14°F to 122°F (-10 °C to 50 °C)
- Storage Temperature : -40 °F to 140 °F (-40 °C to 60 °C)
- Size : 281 mm x 84 mm x 49 mm
- Weight : 520g
FEATURES
- Measure safely with CAT III 1500 V rated clamp meter
- Thin jaw for access to cables in crowded combiner boxes
- Sturdy IP54 rated for outdoor use and solar installation
- Work efficiently with dc power measurement, audio polarity and visual continuity
- AC Current via Jaw
-
Fluke 59 Max Infrared Thermometer
SPECIFICATIONS
- Temperature Range : -30°C to 350°C (-22°F to 662°F)
- Response Time (95%) : < 500 ms (95% of reading)
- Spectral Response : 8 mm to 14 mm
- Emissivity : 0.10 to 1.00
- Distance to Spot Ratio : 8:1 (calculated at 90% energy)
- Display Resolution : 0.1°C (0.2°F)
- Operating Temperature : 0°C to 50°C (32°F to 122°F)
- Storage Temperature : -20°C to +60°C (-4°F to 140°F), (without battery)
- Operating Humidity : 10% to 90% RH non-condensing @ 30°C (86°F)
- Operating Altitude : 2000 meters above mean sea level
- Storage Altitude : 12,000 meters above mean sea level
FEATURES
- Laser targeting for use from -30 °C to 350 °C (-22 °F to 662 °F)
- Small, rugged design easily fits your hand and your toolbox
- Easy-to-read, backlit LCD screen
-
Fluke 59 MAX+ Infrared Thermometer
SPECIFICATIONS
- Temperature Range : -30°C to 500°C (-22°F to 932°F)
- Response Time (95%) : < 500 ms (95% of reading)
- Spectral Response : 8 mm to 14 mm
- Emissivity : 0.10 to 1.00
- Distance to Spot Ratio : 10:1 (calculated at 90% energy)
- Display Resolution : 0.1°C (0.2°F)
- Operating Temperature : 0°C to 50°C (32°F to 122°F)
- Storage Temperature : -20°C to +60°C (-4°F to 140°F), (without battery)
- Operating Humidity : 10% to 90% RH non-condensing @ 30°C (86°F)
- Operating Altitude : 2000 meters above mean sea level
- Storage Altitude : 12,000 meters above mean sea level
FEATURES
- Easy to handle infrared thermometer with precise laser targeting and 10:1 distance to spot ratio
- Measures temperatures from -30°C to 500°C (-22°F to 932°F)
- Provides IP40 rating for extra protection
- Presents a large, backlit LCD display for easy viewing
- Features a small, lightweight design that fits easily fits into your tool bag
-
Fluke 59 Mini Infrared Thermometer
SPECIFICATIONS
- Temperature Range : – 18°C to 275°C (0°F to 525°F)
- Response Time (95%) : < 500 ms
- Spectral Response : 6.5 – 18 um thermopile detector
- Emissivity : 0.95 Pre Set
- Distance to Spot Ratio : 8:1 (calculated at 90% energy)
- Display Resolution : 0.2°C (0.5°F)
- Storage Temperature : -20°C to +65°C (-4°F to 150°F), (without battery)
- Operating Humidity : 10% – 90% RH non-condensing @ up to 30°C(86°F)
FEATURES
- Small in size easily fit in your pocket
- Laser targeting for fast, precise measurements
- Backlit display for easy reading in dark work areas
- 8:1 distance to spot ratios measures a 10 cm spot from 10 meters to target just what you want
- ± 2% basic accuracy gives you readings you can trust
-
FLUKE 62 MAX Infrared Thermometer
SPECIFICATIONS
- Temperature Range : -30°C to 500°C (-22°F to 932°F)
- Response Time (95%) : < 500 ms (95% of reading)
- Spectral Response : 8 mm to 14 mm
- Emissivity : 0.10 to 1.00
- Distance to Spot Ratio : 10:1 (calculated at 90% energy)
- Display Resolution : 0.1°C (0.2°F)
- Operating Temperature : 0°C to 50°C (32°F to 122°F)
- Storage Temperature : -20°C to +60°C (-4°F to 140°F), (without battery)
- Operating Humidity : 10% to 90% RH non-condensing @ 30°C (86°F)
- Operating Altitude : 2000 meters above mean sea level
- Storage Altitude : 12,000 meters above mean sea level
- Safety : IEC 61010-1: Pollution degree 2 ; IEC 60825-1: Class 2
FEATURES
- Highly accurate infrared thermometer for measuring temperatures from -30°C to 500°C (-22°F to 932°F) accurate to +1.5°C or +1.5% of reading (whichever is greater)
- Provides a 10:1 Distance to spot ratio
- Offers single laser targeting for accurate and repeatable measurements
- Features IP54 rating against dust and moisture
-
FLUKE 925 VANE ANEMOMETER
SPECIFICATIONS
- Wind Speed Measurement
m/s : 0.40 to 25.00 m/s
ft/m : 80 to 4900 ft/m - Air Flow Measurement
Cubic meter/ second : 0.01 to 99.99 m3/s
Cubic foot/minute : 1 to 9999 ft3/m - Wind Temperature Measurement
Wind Temperature : 0°C to 50°C - Display : Dual-screen 4-digit (9999 points) LCD screen
- Measurement Unit
Wind speed: ft/m; m/s
Air flow: CMS (m3/s) and CFM (ft3/m) (cubic foot/minute)
Wind temperature: °C and °F - Data Holding : Lock the displayed readings
- Sensor
Wind speed/air flow sensor: conventional angular vane arm, lubricating ball bearing
Wind temperature sensor: precision thermistor
Minimum/maximum value storage, recording and viewing the minimum reading and maximum reading - Auto Power Off : Enter the sleep mode after 20 minutes (can be disabled) to save power
- Battery Life : 100 Hours
- Weight : 363 g, including the battery and sensor
- Dimensions: 181 × 71 × 38 mm
- Sensor head diameter : 70 mm
FEATURES
- Ability to measure wind speed in feet per minute or meters per second
- Data capture using one button and the ability to average multiple readings
- Min and Max alarm setting to alert the user when limits have been met
- Durable over mold housing to protect the unit from drops
- 1 M extension of sensor from display to ensure air flow is captured in hard to reach location
- Wind Speed Measurement
-
Fluke 941 Light Meter
SPECIFICATIONS
- Range : 20, 200, 2000, 20000, 200000 Lux ; 20, 200, 2000, 20000FC (footcandle)
- Sampling Rate : 2.5 times/second for the digital display
- Display : 3½ digit 1999-point LCD screen
- Sensor : Silicon photoelectric diode and optical filter
- Environment : For indoor use
- Dimension : 130 × 63 × 38 mm
Dimension Of Sensor : 80 × 55 × 29 mm - Weight : 220 g (including the battery)
FEATURES
- Measure in lux or foot-candles, with one button to switch between display options
- Measuring range up to 20,000 lux or foot candles
- Data hold to freeze reading on the digital display
- Min/max ability to show high and low readings
- Auto power off to save battery life
- Includes protective sensor cap
-
Fluke 945 Sound Meter
SPECIFICATIONS
- Environmental Noise
Range : 30 to 130 dB
Resolution : 0.1 dB
Accuracy : ±1.5 dB (ref 94dB@1KHZ) - Mechanical Noise :
Range : 30 to 130 dB
Resolution : 0.1 dB
Accuracy : ±1.5 dB (ref 94dB@1KHZ) - Display : 0.1 dB steps on 4-digit LCD screen
- Frequency Response : From 31.5 Hz to 8 kHz
- Dimensions : 200 x 56 32 mm
- Safety Standard : CE, designed to meet IEC651 Type2, ANSI S1.4 Type 2
FEATURES
- Max/Min
- Frequency weighting ranges: A, C
- Auto power off
- Auto ranging
- Backlit display
- Environmental Noise
-
Fluke VT06 Visual IR Thermometer
SPECIFICATIONS
- Infrared resolution : 120×90
- IR frequency band : 7.5~14 μm(long wave)
- Frame Rate : 9 Hz
- Thermal sensitivity/NETD : <60 mk
- Field of view (H x V) : 50° x 37.5°
- Spatial resolution : 7.6 mrad
- Focus system : Focus free
- Minimum focusing distance : 0.5 m (19.7 in)
- Temperature Range : -20 °C to 400 °C ; [-4 °F to 752 °F] (not specified for below -10 °C)
- Temperature Accuracy : ±2°C or 2% @ 23°C±5°C, whichever is greater
- Emissivity : Adjustable
- Operating temperature : -10 °C to 50 °C
- Storage temperature : -40 °C to 70 °C
- Operating altitude : 2000 m (1.24 mi)
- Storage Altitude : 12000 m (7.5 mi)
- Display : 6.096 cm (2.4-inch) LCD
- Size : 20.4 cm x 6.6 cm x 7.6 cm
- Weight : 0.36Kg
- Safety Standard : IEC 61010-1: Pollution Degree 2
FEATURES
- 120 x 90 resolution for more details
- Wide temperature range, -20°C to 400°C
- IP65 rated for dust and water proof, 2m drop test, suitable for harsh industrial environments
- Quickly locate the measured target with built-in laser pointer
- 2 hours charging time, 8 hours battery life
- Single-level menu interface, Open-and-View
-
Fluke VT08 Visual IR thermometer
SPECIFICATIONS
- Infrared resolution : 120×90
- IR frequency band : 7.5~14 μm(long wave)
- Frame Rate : 9 Hz
- Thermal sensitivity/NETD : <60 mk
- Field of view (H x V) : 50° x 37.5°
- Spatial resolution : 7.6 mrad
- Focus system : Focus free
- Minimum focusing distance : 0.5 m (19.7 in)
- Visible resolution : 320×240
- Visible FOV (H x V) : 53° x 41°
- Temperature Range : -20 °C to 400 °C ; [-4 °F to 752 °F] (not specified for below -10 °C)
- Temperature Accuracy : ±2°C or 2% @ 23°C±5°C, whichever is greater
- Emissivity : Adjustable
- Operating temperature : -10 °C to 50 °C
- Storage temperature : -40 °C to 70 °C
- Operating altitude : 2000 m (1.24 mi)
- Storage Altitude : 12000 m (7.5 mi)
- Display : 6.096 cm (2.4-inch) LCD
- Size : 20.4 cm x 6.6 cm x 7.6 cm
- Weight : 0.36Kg
- Safety Standard : IEC 61010-1: Pollution Degree 2
FEATURES
- 120 x 90 resolution for more details
- Wide temperature range, -20 °C to 400 °C
- Blends a visual image with infrared heat image overlay in real-time to clearly distinguish the measured target
- IP65 rated for dust and water proof, 2m drop test, suitable for harsh industrial environments
- Quickly locate the measured target with built-in laser pointer
- 2 hours charging time, 5 hours battery life
- Single-level menu interface, Open-and-View
-
HANNA HI98107 pHep Waterproof Pocket pH Tester with 0.1 pH Resolution
SPECIFICATIONS
- pH Range : 0.0 to 14.0 pH
- pH Resolution : 0.1 pH
- pH Accuracy : ±0.1 pH
- pH Calibration : Automatic, one or two points
- pH Temperature Compensation : Automatic, 0 to 50 oC (32 to 122°F)
- Temperature Range : 0 to 50 oC (32.0 to 122.0oF)
- Temperature Resolution : 0.1 oC / 0.1 °F
- Temperature Accuracy : ±0.5 oC / ±1.0 °F
- Automatic Shut-Off : 8 minutes, 60 minutes, or disabled
- Dimensions : 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
- Weight : 65 g (2.3 oz.) without battery
FEATURES
- Slim, ergonomic design that fits comfortably in the hand or pocket
- Automatic temperature compensation, displays temperature in °C or °F
- Automatic calibration with standard buffers (pH 4.01, 7.01, and 10.01)
- Stability indicator confirms the reading has stabilized
- Automatic shut-off with three user controlled settings to conserve battery life
- Battery Error Prevention System (BEPS)
- An exposed temperature sensor along with an extractable cloth junction ensures a fast and stable temperature compensated measurement
- Only two buttons for meter operation. One for on/off and one for calibration.
-
HANNA HI98301 DiST1, waterproof TDS tester with ATC, 1999 ppm (mg/L)
SPECIFICATIONS
- TDS Range : 0 to 2000 ppm (mg/L)
- TDS Resolution : 1 ppm (mg/L)
- TDS Accuracy : ±2% F.S.
- TDS Calibration : automatic, one point at 1382 ppm
- EC/TDS Temperature Compensation : automatic from 0 to 50°C (32 to 122°F)
- Temperature Correction Coefficient : 1.9%/°C
- EC to TDS Conversion Factor : 0.5
- Temperature Range : 0.0 to 50.0°C (32.0 to 122.0°F)
- Temperature Resolution : 0.1°C (0.1°F)
- Temperature Accuracy : ±0.5°C (±1°F)
- Automatic Shut-Off : 8 minutes, 60 minutes, or disabled
- Environment : 0 to 50°C (32 to 122°F); RH 100%
- Dimensions : 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
- Weight : 68 g (2.4 oz.) without battery
FEATURES
- Slim, Ergonomic Design
With rounded edges and a case that is only 17 mm (0.7”) thick, the HI98301 is thin and fits comfortably in the hand or pocket. - Large Multi-level LCD
The LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both the pH and temperature simultaneously. - Two-button Operation
One for ON/OFF, the other for calibration. - Exposed Temperature Sensor
Exposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either oC or oF. - Graphite Sensor
Reduces polarization effects and does not oxidize resulting in a reliable and accurate reading.
- Automatic Calibration
Automatic calibration at 1382 ppm (mg/L) with a single push of a button. - Stability Indicator
A clock tag stability indicator will disappear to alert the user when the reading is stable. - Automatic Shut-off
User-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled. - Low Battery Indicator
Low battery indicator that is displayed when less than 10% battery life is remaining. - Battery % Level at Startup
At start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed
-
HIOKI AC CLAMP METER 3280-10F
SPECIFICATIONS
- AC Current range : 41.99 to 1000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy: ±1.5 % rdg. ±5 dgt.
- DC Voltage range : 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.
- AC Voltage range : 4.199 V to 600 V, 4 ranges (45 to 500 Hz, Average rectified), Basic accuracy: ±1.8 % rdg. ±7 dgt.\
- Resistance range : 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.
- Other functions : Continuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter
- Display : LCD, max. 4199 dgt., Display refresh rate: 400 ms
- Environmental protection : IP40 dustproof and waterproof
- Power supply : Coin type lithium battery (CR2032) ×1, Continuous use 120 hours
- Core jaw dia. : φ 33 mm (1.30 in)
- Dimensions and mass : 57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz)
FEATURES
- Measure the fundamental waveform component using the average rectified method
- Expanded -25°C to 65°C operating temperature range
- Connect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires
- Drop proof design withstands drop from a height of 1 meter
-
HIOKI AC/DC CLAMP METER CM4371-50
SPECIFICATIONS
- DC Current range : 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
- AC Current range : 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A
- Crest factor : 20.00 A range: 7.5 ; 600.0 A range: 3 or less
- DC+AC Current range : 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
- DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
- AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
- DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
- Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
- Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
- Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
- Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
- Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
- Dustproof, waterproof : IP54 (Storage or measurement of current of an insulated conductor)
- Core jaw diameter : φ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in)
- Power supply : LR03 Alkaline battery ×2 ; Continuous use: 40 hr (without Z3210 installed), 20 hr. (with Z3210 installed and using wireless communications) ; Other conditions: 10 A AC measurement, backlight off, 23°C reference value
FEATURES
- CAT IV 600 V, CAT III 1000 V When using the P2000: CAT III 2000 V, CAT IV 1000 V
- Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file
- Harmonic analysis from 1st to 30th order with our free app GENNECT Cross
- Automatic AC/DC function helps boost work efficiency
-
HIOKI AC/DC CLAMP METER CM4373-50
SPECIFICATIONS
- DC Current Range : 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)
- AC Current Range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)
- Crest factor : 600.0 A range: 3 or less ; 2000 A range: 2.84 or less
- DC+AC Current range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)
- DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
- AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
- DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
- Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
- Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
- Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
- Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
- Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
FEATURES
- CAT IV 600 V, CAT III 1000 V
When using P2000: CAT III 2000 V, CAT IV 1000 V - Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
- Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
- Automatic AC/DC function helps boost work efficiency