Showing 49–64 of 353 results

  • BEETECH TP-101 THERMOMETER WITH PROBE

    SPECIFICATIONS

    • Battery : 1.5V
    • Temperature measurement : -50°C ~ 300°C (-58°F ~ 572°F)

    FEATURES

    •  Temperature Accuracy: ±1°C/°F
    •  Temperature Display
    •  Data Hold Function
    •  Temperature units °C / °F changeable
    •  Max/Min Temperature memory
    Read more
  • BOSCH DETECTOR DTECT 200C

    TECHNICAL DETAILS

    • Dust and splash protection : IP 5X
    • Bosch Radar Technology : Yes
    • Max. detection depth : 200mm
    • Detectable objects : magnetic metals (e.g. iron), non-magnetic metals (e.g. copper), live cables, low-voltage & data cables (Three-phase power cables, cavities), non-live cables, wooden substructures, water-filled plastic pipes, Empty plastic pipes
    • Detection depth, dry concrete, max. : 200mm
    • Detection depth, early age concrete, max. : 60mm
    • Detection depth, other wall types, max. : 80mm
    • Detection depth, magnetic metal, max. : 200mm
    • Detection depth, non-magnetic metal, max. : 80mm
    • Detection depth, live cables, max. : 80mm
    • Detection depth, wooden substructures, max. : 38mm
    • Accuracy : ±5 mm
    • Views : Object view, Spot view, Signal View, Signal View 2D
    • Wall types : Concrete, Early age concrete, Drywall, Brick/Universal, Horizontal coring brick, Vertical coring brick, Panel Heating
    • Documentation via : USB-C, SD-Card
    • Updatable : Yes
    • Material identification : Magnetic metal, Non-magnetic metal, Non-metal material, Live cable
    • Power supply : 12 V Li-Ion battery, 10.8 V-LI ION battery, 4 x 1.5 V LR6 (AA)
    • Weight : 0.64 kg
    • Additional function : Leakage detection, distance measurement
    Read more
  • BOSCH GIS 500 PROFESSIONAL THERMO DETECTOR

    SPECIFICATIONS 

    • Measuring accuracy of IR : ± 1.8 °C* (*plus use-dependent deviation)
    • Laser diode : Laser class 2, 635 nm
    • Power supply and runtime : 2 x 1.5V LR6 (AA) batteries 9h
    • Weight : 0.22KG
    • Operating temperature : -5 – 50 °C
    • Storage  temperature: -20 – 70 °C
    • Optics : 12:1
    • Measurement Range : Surface temperature, -30 ⁰C to +500 ⁰C
    • Measuring accuracy (typical) : Surface temperature, -30 ℃ ≤ t ≤ -10 ℃: ± (1.8 ℃ + 0.1 x |t| ℃), -10 ℃ < t < 0 ℃: ± 2.8 ℃, 0 ℃ ≤ t < 100 ℃: ±1.8 ℃, 100 ℃ ≤ t ≤ 500 ℃: ± 1.8%
    • Measurement Application   : Spot temperature measurement
    Read more
  • BOSCH GLL 5-50X LINE LASER

    TECHNICAL DATA

    • Working range with receiver, value : 50m
    • Working range : 15m
    • Working range with receiver : 50m
    • Accuracy : Horizontal laser line: ± 0.2 mm/m* ; Vertical laser lines: ± 0.3 mm/m* (*plus use-dependent deviation)
    • Working range, value : 15m
    • Laser diode : 630 – 650 nm, < 1mW
    • Operating temperature : -10 – 45 °C
    • Storage temperature : -20 – 70 °C
    • Laser class : 2
    • Working range of laser points, max. : 5m
    • Self-levelling range : ± 3°
    • Levelling time : 4s
    • Power supply : 4 x 1.5 V LR6 (AA)
    • Operating time (max.) : 24h
    • Tripod thread : 5/8″
    • Weight, approx. : 0.5kg
    • Colour of laser line/plumb points : Red
    • Plumb point accuracy : ± 0.7 mm/m* (*plus use-dependent deviation)
    Read more
  • BOSCH GLM 100-25C Laser Measure

    TECHNICAL DETAILS 

    • Measuring range, up to : 100 m
    • Dust and splash protection : IP 54
    • Measurement time, typical : < 0.5 s
    • Units of measurement : m/cm, ft/inch
    • Laser diode : 650 nm, < 1 mW
    • Measurement range : 0.08 – 100.00 m
    • Laser class : 2
    • Measurement accuracy, typical : ± 1.5 mmᵈ
    • Measurement range of incline measurement : 0 – 360° (4 x 90°)
    • Measuring accuracy (typical) : ± 0.2°* (*plus use-dependent deviation)
    • Measurement time, max. : 4 s
    • Power supply : 3 x 1.5 V LR6 (AA)
    • Automatic deactivation : 5 min
    • Weight, approx. : 0.23 kg
    • Memory capacity (values) : 50
    • Tripod thread : 1/4″
    • Digital viewfinder : integrated
    • Data transfer : Bluetooth™ 4.2 Low Energy
    • Laser color : Red
    Read more
  • BOSCH GLM 30-23 Laser Measure

    TECHNICAL DETAILS

    • Laser Diode : 635 nm, < 1 mW
    • Measurement range : 0.15 – 30.00 m
    • Weight, approx. : 0.09 kg
    • Measurement time, typical : 0.5 s
    • Units of measurement : m/cm
    • Laser class : 2
    • Measurement accuracy, typical : ± 1.5 mmᵈ
    • Measurement time, max. : 4.2 s
    • Power supply : 2 x 1.5 V LR03 (AAA)
    • Automatic deactivation : 5 min
    • Laser colour : Red
    • Measuring range, up to : 30m
    Read more
  • BOSCH GLM 50-23G Laser Measure

    TECHNICAL DETAILS 

    • Dust and splash protection : IP 65
    • Measuring range, up to : 50M
    • Laser colour : Green
    • Measurement time, typical : < 0.5 s
    • Units of measurement : m/cm, ft/inch
    • Laser diode : 515 nm, < 1 mW
    • Measurement range : 0.05 – 50.00 m
    • Laser class : 2
    • Measurement accuracy, typical : ± 1.5 mmᵈ
    • Measurement range of incline measurement : 0 – 360° (4 x 90°)
    • Measuring accuracy (typical) : ± 0.2°* (*plus use-dependent deviation)
    • Measurement time, max. : 4 s
    • Power supply : 2 x 1.5 V LR6 (AA)
    • Automatic deactivation : 5 min
    • Weight, approx. : 0.2kg
    • Memory capacity (values) : 30
    • Tripod thread : 1/4″
    • Laser colour : Green
    Read more
  • BOSCH GLM 50-27 CG PROFESSIONAL LASER MEASURE

    SPECIFICATIONS 

    • Dust and Splash Protection : IP 65
    • Laser Diode : 515 nm, < 1 mW
    • Measurement Range : 0.05 – 50.00 m
    • Weight : 0.2 kg
    • Unit of Measurement : m/cm, ft/inch
    • Laser Class : 2
    • Measurement accuracy, typical : ± 1.5 mm* (*plus use-dependent deviation)
    • Measurement time : 4s
    • Power Supply : 2 x 1.5 V LR6 (AA)
    • Memory Capacity : 30 values
    • Data transfer : Bluetooth™ 4.2 Low Energy
    • Automatic Deactivation : 5 Minutes
    • Tripod Thread : 1/4″
    • Laser Colour : Red
    Read more
  • BOSCH GLM-150C Professional

    TECHNICAL DETAILS 

    • Dust and splash protection : IP 54
    • Laser diode : 650 nm, < 1 mW
    • Measurement range : 0.08 – 150.00 m
    • Weight, approx. : 0.23KG
    • Units of measurement : m/cm, ft/inch
    • Laser class : 2
    • Measurement accuracy, typical : ± 1.5 mmᵈ
    • Power Supply : 3 x 1.5 V LR6 batteries (AA)
    • Automatic deactivation : 0 min
    • Memory Capacity : 50
    • Tripod thread : 1/4″
    • Digital viewfinder : integrated
    • Data transfer : Bluetooth™ Smart
    • Supported Android devices : Smartphone with Android 4.3 or higher
    • Supported iOS devices : iPhone 4S or higher, iPad (3rd Gen. or higher), iPad Air (1st Gen. or higher), iPad mini (1st Gen. or higher)
    • Laser color : Red
    • Range : 150 m
    Read more
  • BOSCH GLM-40 PROFESSIONAL

    SPECIFICATIONS

    • Laser Diode : 635 nm, < 1 mW
    • Measurement Range : 0.05 – 40.00 m
    • Weight : 0.1 kg
    • Measurement time : < 0.5 s
    • Laser Class : 2
    • Measurement accuracy, typical : ± 2.0 mm* (*plus use-dependent deviation)
    • Power Supply : 2 x 1.5 V LR03 (AAA
    • Automatic Deactivation : 5 Minutes
    • Laser Colour : Red
    Read more
  • BOSCH GLM-400 RPOFESSIONAL

    SPECIFICATIONS

    • Dust and Splash Protection : IP 54
    • Laser Diode : 635 nm, < 1 mW
    • Measurement Range : 0.05 – 40.00 m
    • Weight : 0.1 kg
    • Unit of Measurement : m/cm, ft/inch
    • Laser Class : 2
    • Measurement accuracy, typical : ± 1.5 mm* (*plus use-dependent deviation)
    • Power Supply : 2 x 1.5 V LR03 (AAA
    • Automatic Deactivation : 5 Minutes
    • Tripod Thread : 1/4″
    • Laser Colour : Red
    Read more
  • BOSCH GTC 400 C PROFESSIONAL THERMAL CAMERA

    SPECIFICATIONS

    • Measuring application : Thermal image
    • Battery voltage : 12
    • Measurement range : -10 °C to +400 °C
    • Measuring accuracy of IR : ± 3.0 °C* (*plus use-dependent deviation)
    • Data Transfer : MicroUSB, Wi-Fi
    • Thermal sensitivity (NETD) : <50 mK
    • Resolution : 0.1 °C
    • Size of IR sensor : 160×120 px
    • Number of measuring points : 19200
    • Field of view (FOV) : 53×43 °
    • Power supply and runtime : 4 x 1.5 V LR6 (AA) 1 x GBA 12V 1 x GBA 10.8V
    • Frame buffer (number of images)  : 500
    • Memory type : Internal memory
    • File format of image : .jpg
    • Dust and splash protection : IP 53
    • Weight : 0.54Kg

    Features

    • Fast exchange of data and easy documentation of thermal images with the Bosch Thermal App
    • Picture-in-picture technology overlays thermal and real images for easy-to-see localisation of the measurement
    • Flexible battery system can be powered by a 12 V LI-ION battery or with standard alkaline batteries
    Read more
  • BOSCH THERMAL IMAGER GTC-400C Professional

    TECHNICAL DETAILS 

    • Measurement Range : -10 °C to +400 °C
    • Measuring accuracy of IR : ± 3.0 °Cᵇ
    • Battery voltage : 12.0 V
    • Thermal sensitivity (NETD) : <50 mK
    • Resolution : 0.1 °C
    • Size of IR Sensor : 160×120 px
    • Number of measuring points : 19200
    • FOV Field of View : 53×43 °
    • Power supply and runtime : 4 x 1.5 V LR6 (AA) 1 x GBA 12V 1 x GBA 10.8V
    • Frame buffer (number of images) : 500
    • Memory type : Internal memory
    • File format of image : .jpg
    • Data transfer : MicroUSB, Wi-Fi
    • Dust and splash protection : IP 53
    • Weight : 0.54 kg
    • Size of display : 3,5″
    • Operating temperature : -10 – 45 °C
    • Storage temperature : -20 – 70 °C
    • Focus distance, minimum : 0.3m
    • Measuring application : Thermal image
    Read more
  • CIE DET-2000 Digital Earth Tester

    SPECIFICATIONS

    • Display : 3.5 digits,L.C.D
    • Accuracy :
      0% to 10% of the range…….+3%
      10% to 90% of the range……+1.5%
      90% to 100% of the range……+3%
    • H.V Test : 2KV AC For 1 min. Between electrical circuit and containing case
    • Insulation Resistance Test : More than 25M Ohm at 500V dc between electrical circuit

    FEATURES

    • Rugged ABS Body
    • 0-10 — 1000 Ohm
    • Easy to use hand held meter
    • Ni-cd rechargeable cells
    • Facility as to make bench top type instrument
    • Four terminals
    • Designed to measure the resistance of earth used in power circuit
    Read more
  • Fluke 101 Digital Multimeter

    SPECIFICATIONS 

    • AC Volts :
      Range : 600V
      Resolution : 0.1 V
      Accuracy : 1.0% + 3
    • DC Volts :
      Range : 600V
      Resolution : 0.1 V
      Accuracy : 0.5% + 3
    • Resistance :
      Range : 40.00 MΩ
      Resolution : 0.01 MΩ
      Accuracy : 1.5% + 3
    • Capacitance :
      Range : 1000 μF
      Resolution : 1 μF
    • Frequency :
      Range : 100.0 kHz
      Resolution : 0.1 kHz
    • IP Rating : IP 40

    FEATURES

    • Basic dc accuracy 0.5%
    • CAT III 600 V safety rated
    • Diode and continuity test with buzzer
    • Small lightweight design for one-handed use
    • Rugged, durable design
    • Automatic shutdown
    • Battery is easy to replace
    Read more
  • Fluke 106 Palm-sized Digital Multimeter

    SPECIFICATIONS 

    • AC Volts :
      Range : 600V
      Resolution : 0.1 V
      Accuracy : 1.0% + 3
    • DC Volts :
      Range : 600V
      Resolution : 0.1 V
      Accuracy : 0.5% + 3
    • Resistance :
      Range : 40.00 MΩ
      Resolution : 0.01 MΩ
      Accuracy : 1.5% + 3
    • Capacitance :
      Range : 1000 μF
      Resolution : 1 μF
      Accuracy : 5 % + 5
    • Frequency :
      Range : 100.0 kHz
      Resolution : 0.1 kHz
    • Temperature :
      Operating : 0 °C to 40 °C
      Storage : -30 °C to 60 °C
    • IP Rating : IEC 60529: IP 40
    • Safety : IEC 61010-1: 600 V CAT III, Pollution Degree 2

    FEATURES

    • Voltage, resistance, continuity, capacitance
    • Input terminal for ac and dc current measurements to 10 A and current
    • Data hold
    Read more