HTC PM-6202 Digital Manometer
SPECIFICATIONS
inH20
- RANGE : ±55.40
- RESOLUTION : 0.01
Psi
- RANGE : ±2.000
- RESOLUTION : 0.001
mbar
- RANGE : ±137.8
- RESOLUTION : 0.1
KPa
- RANGE : ±13.79
- RESOLUTION : 0.01
inHg
- RANGE : ±4.072
- RESOLUTION : 0.001
- Accuracy : ±0.3% FSO (25oC)
- Linearity/Hysteresis : ±0.29% FSO
- Repeatability : ±0.2%
- Pressure range : ± 2 psi
- Maximum pressure : ± 10 psi
- Response time : 0.5 Seconds typical
- Low battery indicator : YES
- Over range indicator : Err.1
- Under range indicator : Err.2
- Operating Conditions : 0 to 50 o C
- Storage conditions : 10 to 60 o C
- Power : 9V (6F22) X 1
FEATURES
- Large Dual LCD with backlight
- Data hold
- Max./Min. Average value with relative time stamp
- Zero adjust, offset & Different function
- Auto Power Off
- Low battery indication
- USB Computer Interface
(Advanced Software program for all windows
-
HTC PM-6205 Digital Manometer
SPECIFICATIONS
inH20
- RANGE : ±55.40
- RESOLUTION : 0.01
Psi
- RANGE : ±2.000
- RESOLUTION : 0.001
mbar
- RANGE : ±137.8
- RESOLUTION : 0.1
KPa
- RANGE : ±13.79
- RESOLUTION : 0.01
inHg
- RANGE : ±4.072
- RESOLUTION : 0.001
- Accuracy : ±0.3% FSO (25oC)
- Linearity/Hysteresis : ±0.29% FSO
- Repeatability : ±0.2%
- Pressure range : ± 2 psi
- Maximum pressure : ± 10 psi
- Response time : 0.5 Seconds typical
- Low battery indicator : YES
- Over range indicator : Err.1
- Under range indicator : Err.2
- Operating Conditions : 0 to 50 o C
- Storage conditions : 10 to 60 o C
- Power : 9V (6F22) X 1
FEATURES
- Large Dual LCD with backlight
- Data hold
- Max./Min. Average value with relative time stamp
- Zero adjust, offset & Different function
- Auto Power Off
- Low battery indication
- USB Computer Interface
(Advanced Software program for all windows
-
HTC PVB-805 Vibration Meter
SPECIFICATIONS
- Sensor : Piezoelectric Accelerated Sensor
- Acceleration Measurement Range : 0.1~199.9m/s2 (peak value)
- Velocity Measurement Range : 0.1~199.9mm/s(real-time valid value)
- Displacement Measurement Range : 0.001~1.999mm(peak-peak value)
- Accuracy : ±(5%+2dgts)
- Low Frequency Acceleration Measuring Frequency Range : 10Hz~1KHz
- High Frequency Acceleration Measuring Frequency Range : 1KHz~10KHz
- Velocity Measuring Frequency Range : 10Hz~1KHz
- Displacement Measuring Frequency Range : 10Hz~500Hz
- Data Refresh Time : 500 ms
- Storage Capacity : 200 sets
- Power : 2*1.5V AAA battery
- Battery Working Life : > 4 Hours
- Working Temperature : 0°C~50°C
- Storage Temperature : -20°C~60°C
- Working Humidity : 20%RH~80%RH
- Storage Humidity : 20%RH~80%RH
- Dimension : 176*54*25mm
- Weight : 121 g
- Height above sea level : <2000
FEATURES
- Frequency Range-10Hz~10KHz
- Short and Long Probes are for displacement, velocity and acceleration
- Auto Power Off (APO)
- User Can Check historical data view on screen
-
HTC SL-1350 Sound Level Meter
SPECIFICATIONS
- Frequency : 31.5Hz-8KHz
- Resolution : 30~130dB (A) ; 35~130dB (C) ; 35~130dB (F)
- Accuracy : 0.1 dB
FEATURES
- DC Output: 0~1.3V 10mV/dB
- ‘A’,’C’ or ‘Flat’ weighing with Slow / Fast response
- 94dB in Full calibration at (1KHz)
- Optional RS-232 Communication (Advanced Software Program for all windows)
- Alarm Volume o/p: 30~130dB
- Alarm Volume o/p: LED Optional Relay output
Measurements
- LP: Current sound pressure level
- Leq : Equivalent Continuous Asound pressure level (i.e. Arithmetically mean value in a period of time set)
- LN : Statistic analysis i.e. % of all measured values which is greater than or equal to the alarm value (Alarm set by user)
- Standard Accessories: Hard Carrying Case, Wind Screen Ball, Manual
- Optional Accessories: HTC Software with RS-232 USB Cable
- Dimension: 236(H) x 63(W) x 26(D)mm
Special Function
Memory : Max. Value (30 groups)
Power : AAA 1.5V x 4
Alarm : Electron
-
HTC SL-1352 Digital Sound Level Meter
SPECIFICATIONS
- Accuracy : ± 1.4dB
- Resolution : 0.1dB
- Frequency Range : 3.5~8KHz
- Dynamic Range : 50dB
- Level Range : Low: 30~80dB Medium 50~100dB ; High: 80~130dB Auto: 30~130dB
- Time Weighting : FAST (125mS), SLOW (1s)
- Sensor : ½ “ electric condensor microphone
- Display Update : 2 times/sec
- Analog Output : AC/DC Outputs, AC = 1Vrms, DC=10mV/dB
FEATURES
- Max./Min Measurement
- Over Range Display / Under range display
- A & C Weighing
- FAST & SLOW Response
- Adjustable Alarm Levels
- Backlight / Data Logging
- USB Computer Interface (Advanced Software Program for all windows)
- Power : 9V (6F22) X 1
- Standard Accessories : Gift Box with Hard Carrying Case, Manual, Audio Plug, Windscreen Ball, & DC 9V Power Supply, USB Cable & Software
- Dimension : 252(H) x 66(W) x 33(D)mm
-
HTC ST-852 3 Phase Rotation Meter
SPECIFICATIONS
- Operational Voltage : 200~480V (3 Phase AC)
- Withstand Voltage :4000V for 1 minute
- Measuring Frequency Range : 20~400Hz
- Time Limit for Continuous measurement :
Less than 60 minutes at 200 VAC
Less than 40 minutes at 400 VAC
FEATURES
- Standard Accessories : Test Lead (attached to meter ), Alligator Clips , Carrying Case, Manual
- Dimension : 85(H) x 64(W) x 23(D)mm
-
HTC TT-825 3 1/2 DIGITS Transistor Tester
SPECIFICATIONS
- V(BR) : 1000V
- Vcc(set) : 200V
- HFE : 800mA(Ic)
- Iceo : 10mA(Ib)
- Voltage of Thread-end : 78xx/79xx
FEATURES
- 3½ Digit LCD Display
- 1,999 Count
- Data Hold Function
- Auto Range
- Measuring forward voltage, reverse voltage, forward satuaration voltage drop, amplification factor, reverse leakage current of various crystal diode, audios, silicon controlled rectifier(SCR), field effect transister(FET)
- Measuring rated working voltage of chemical capacitor, ethylene capacitor, a capacitor, leaded multilayer ceramic capacitor, high voltage locker.
- Measuring protection voltage of varistor.
- Measuring starting voltage of neon bulb, neon lamp
- Measuring constant voltage value of 78,79 series three-pole circuit.
-
HTC VB-8205 VIBRATION METER
SPECIFICATIONS
- Acceleration : 10Hz~10KHz (Mode 10) ; 10Hz~1KHz (Mode 1)
- Velocity : 10Hz~1KHz
- Displacement : 10Hz~1KHz
- Revolution/min RPM : 60~99.990r/min (rdg. Should be multiplied by 10 if the displays show 10)
- Frequency : 1~20KHz
FEATURES
- Measure Accelerator / Velocity / Displacement with RPM & Frequency
- Metric / Imperial Measurement
- AC output socket for headphones and recording
- Optional Headphones for use as electronic stethoscope
- Optional RS-232 Communication (Advanced Software Program for all windows)
- POWER : AAA 1.5V X 4
- Standard Accessories : Magnet, Accelerometer, Stinger Probe (Cone), Stinger Probe (Ball) , Hard Carrying Case, Manual
- Optical Accessories : HTC Software with RS-232 USB Cable
- Dimension : 124(H) x 62(W) x 30(D)mm
-
HTC VT-100 Thermal Imager Camera
SPECIFICATIONS
- Display : 2.5”colour LCD
- IR Solution : 3600 Pixels
- Visible Light Image & Resolution : 300000 Pixels
- Field of view : 20×20˚
- Thermal sensitivity : 0.15˚C/0.27˚F
- Temperature range : -20~300˚C/-4~572˚F
- Accuracy : ±2% or reading±2˚C/3.6˚F
- Emissivity : Adjustable 0.1~1.0
- Image frequency : 6hz
- Spectral band : 8-14um
- Relative Humidity : 10~80%RH
- Storage Temperature : -20~55˚C/-4~131˚F
FEATURES
- TFT Coloure lcd display
- Adjustable emissivity and reflected background compensation improves measurement accuracy on semi-reflective surface
- Hot and Cold spot temperature markers that guide the user to the hottest and coldest regions in the infrared heat map
- Select Coloure palette
- Visual and heat map image alignment
- Image capture and save it in SD Card
- Power : AA 1.5V X 4
- Battery life : 6Hrs.
- Weight : 310g
- Dimension : 223(H) x 88(W) x 65(D)mm
-
KEW 3125A High Voltage Insulation Tester
SPECIFICATIONS
- Rated Voltage : 250 V / 500v / 1000v / 2500v / 5000v
- Accuracy : ±5%rdg±3dgt ±20%rdg (100GΩ or more)
- Short Circuit Current : 1.5mA
- Dimensions : 177 (L) × 226 (W) × 100 (D) mm / 300 (L) × 315 (W) × 125 (D) mm (Hard case)
- Weight : 3125A: 1.9kg approx. (including batteries) 4kg approx. (including accessories)
FEATURES
- Insulation Resistance up to 1TΩ
- Short-Circuit Current up to 1.5mA
- Wide Test Voltage from 250V to 5000V
- Diagnosis Function of PI and DAR
- Newly-designed alligator clip
- It comes with a tough hard case
- Filter function reduces noise interference for obtaining stable measurement
- Large display with Bar Graph indication and backlight
- Live voltage warning
- Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
-
Lutron AM-4201 Digital Anemometer
SPECIFICATIONS
AIR VELOCITY
- MEASUREMENT : m/s
- RANGE : 0.4-30.0 m/s
- RESOLUTION : 0.1 m/s
- ACCURACY : ± ( 2%+0.2 m/s )
- MEASUREMENT : km/h
- RANGE : 1.4-108.0 km/h
- RESOLUTION : 0.1 km/h
- ACCURACY : ± ( 2%+0.8 km/h )
FEATURES
- The portable anemometer provides fast accurate readings with digital readability and the convenience of a remote sensor separately.
- Multi-functions for air flow measurement: m/s, km/h, ft/min, knots.
- Low-friction ball-bearing design resulting in accuracy at both high and low velocities.
- Conventional twisted vane arms, always a source of unreliability have been eliminated.
- DATA HOLD.
- Compact housing cabinate.
- Wide applications: use this anemometer to check air conditioning & heating systems, measure air velocities, wind speeds, temperature…etc.
- Display : LCD 65 x 25 mm, 3 1/2 digits.
- Power Supply : DC 9V 006P, MN1604(PP3) battery (Heavy Duty Type) or equivalent.
- Dimensions : 168 x 80 x 35mm (6.6 x 3.2 x 1.2 inch)
- Standard Accessories : Instruction Manual, Sensor Probe , Carrying Case
- Operating Humidity : Less than 80 % RH.
-
Lutron AM-4202 Digital Anemometer With Temperature
SPECIFICATIONS
AIR VELOCITY
- MEASUREMENT : m/s
- RANGE : 0.4-30.0 m/s
- RESOLUTION : 0.1 m/s
- ACCURACY : ± ( 2%+0.2 m/s )
- MEASUREMENT : km/h
- RANGE : 1.4-108.0 km/h
- RESOLUTION : 0.1 km/h
- ACCURACY : ± ( 2%+0.8 km/h )
FEATURES
- The portable anemometer provides fast accurate readings with digital readability and the convenience of a remote sensor separately.
- Multi-functions for air flow measurement: m/s, km/h, ft/min, knots.
- temperature measurement. ℃ ℉
- Low-friction ball-bearing design resulting in accuracy at both high and low velocities.
- Conventional twisted vane arms, always a source of unreliability have been eliminated.
- DATA HOLD.
- Compact housing cabinate.
- Wide applications: use this anemometer to check air conditioning & heating systems, measure air velocities, wind speeds, temperature…etc.
- Temp. Sensor : Naked-bead type k thermocouple probe
- Display LCD 65 x 25 mm
- Operating Temp : 0 ℃ to 50℃ (32℉ to 122℉ ).
- Operating Humidity : Less than 80 % RH.
- Standard Accessories : Instruction Manual, Sensor Probe , Carrying Case
- Dimensions : 168 x 80 x 35mm (6.6 x 3.2 x 1.2 inch)
- Weight : 325 g/0.72 LB.
- Power Consumption : Approx. DC 9 mA
-
LUTRON AM-4204 Hot Wire Anemometer
SPECIFICATIONS
- Circuit : Custom one-chip of micro-processor LSI circuit.
- Display : 13 mm(0.5″) Super large LCD display. Dual function meter’s display.
- Measurement :
in/s (meters per second)
km/h (kilometers per hour)
if/mm (feet/per minute)
knots (nautical miles per hour)
mile/h(miles per hour)
Temp. -°C, °F.
Data hold. - Sensor Structure : Air velocity: Tiny glass bead thermistor
- Temperature : 0 ℃ to 50 ℃ ( 32 ℉ to 122 ℉)
- Operating Humidity : Less than 80% RH.
- Power Supply : 1.5 V AAA (UM-4) battery x 6 PCs (Alkaline or heavy duty type).
- Memory : Maximum and Minimum with recall.
- Sampling Time: Approx. 0.8 sec
- Data Output : RS 232 PC serial interface
FEATURES- Thermal anemometer, available for very low air velocity measurement
- Slim probe, ideal for grilles & diffusers.
- Combination of hot wire and standard thermistor, deliver rapid and precise measurements even at low air velocity value.
- Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
- Super large LCD with dual function meter’s display, read the air velocity & temp. at the same time.
- Heavy duty & compact housing case.
- Records Maximum and Minimum readings with recall Data hold.
- Auto shut off’ saves battery life.
- Operates from 6 PCS UM-4 batteries.
- RS 232 PC serial interface.
- The portable anemometer provides fast, accurate readings, with digital readability and the convenience of a remote probe separately.
- Multi- functions for air flow measurement:
m/s, km/h, ft/mm, knots. mile/h. - Build in temperature 0C, 0 F measurement.
- Thermistor sensor for Temp. measurement, fast response time.
- Used the durable, long-lasting components, including a strong, light weight ABS- plastic housing case.
- Deluxe hard carrying case.
- Applications : Environmental testing, Air conveyors, Elow hoods, Clean
rooms, Air velocity, Air balancing, Fans/motors/blowers, Furnace
velocity, Refrigerated case, Paint spray booths.
-
LUTRON CO and CO2 meter AQ-9901SD
SPECIFICATIONS
- Circuit : Custom one-chip of microprocessor LSI circuit.
- Display : LCD size : 52 mm x 38 mm ; LCD with green backlight ( ON/OFF ).
- Measurement :
CO2 (Carbon dioxide )
CO ( Carbon monoxide )
O2 ( Oxygen in air )
Humidity
Dew point Temp., Wet bulb Temp. - Data error number : 0.1% of total saved data max.
- Memory Card : SD memory card. 1 GB to 16 GB.
- Sampling time of display : Approx. 1 second.
- Power Supply : AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.
ELECTRICAL SPECIFICATIONS
- CO2 ( Carbon dioxide )
Range : 0 to 4,000 ppm
Resolution : 1 ppm
Accuracy : ± 40 ppm : 1,000 ppm ; ± 5% of reading : > 1,000 ppm 3,000 ppm ; ± 250 ppm typically : > 3,000 ppm, reference only - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
- CO ( Carbon dioxide )
Range : 0 to 1,000 ppm
Resolution : 1 ppm
Accuracy : ± ( 5% + 2 ppm )
Response Time : < 30 seconds
Sensitivity Drift : < 5% per year - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
- O2 ( Air oxygen )
Range : 0 to 30 %O2.
Resolution : 0.1 %O2.
Accuracy : ± ( 1 % reading + 0.2 % O2 )
Response Time : <= 15 seconds
Sensitivity Drift : < 5% per year
Overload Protection : 100 %O2.
Environment Pressure Range : 0.9 to 1.1 atmosphere. - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
FEATURES
- RS232/USB computer interface.
- Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional .
- Separate probe, easy for remote measurements.
- Complete set of 4 probes : CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe,Humidity/Temp. probe, main meter and the hard carrying case.
- Sampling time for data recorder is 2 seconds to 8 hours
- Alarm setting with the beeper sound output
- Humidity sensor : Precision capacitance sensor
- CO, O2 sensor : Galvanic cell type.
- CO range : 0 to 1,000 ppm x 1 ppm
- O2 range : 0 to 30.0 % x 0.1 %.
- CO2 range : 0 to 4,000 ppm x 1 ppm.
-
LUTRON DL-6054 AC LEAKAGE TESTER
SPECIFICATIONS
- Current Range (AC) : 200mA – 200A
- AC Current Resolution : 0.1mA – 0.1A
-
Current Accuracy (AC) : ± ( 1.2 % + 5d )
-
Jaw Opening Size : 19mm
-
Operating Temperature : 0˚C ~ 50˚C
- Battery : 9V battery
FEATURES
- High precision AC mA measurement, it is useful for AC mA leakage current measurement.
- Measure AC mA on the inductive conductor.
- Miniature type, easy to carry out & operation.
- High precision for low ACA leakage current measurement.
- Built-in DATA HOLD function.
- Crystal time base, high quality.
- LCD display allows clear readout-out even at high ambient light level.
- LSI circuit provides high reliability and durability.
- Overload protection circuit is provided for all range.
- Design to meet IEC 1010 safety requirement.
- Compact, light weight and excellent operation.
-
LUTRON DO-5509 DISSOLVED OXYGEN METER
SPECIFICATIONS
- Display : 13 mm ( 0.5″ ) LCD, 3 1/2 digits.
- Measurement Range : Dissolved Oxygen – 0 to 20.0 mg/L.
- Resolution : 0.1 mg/L.
- Accuracy : ± 0.4 mg/L. (after calibration within 23± 5 ) ℃
- Sensor Temp Compensation : Automatic from 0 to 40 . ℃
- Panel adj. knob : ZERO knob, CAL knob.
- Battery : 006P DC 9V battery ( heavy duty ).
- Power Consumption : Approx. DC 3.5 mA.
- Operating Temp. : 0 to 50 (32 to 122 ). ℃ ℃℉ ℉
- Operating Humidity : Less than 80% RH.
GENERAL DESCRIPTION
- This Digital Dissolved Oxygen Meter is supplied with a polarographic type probe with an incorporated Temp. sensor which serves for precise Dissolved Oxygen ( DO ) and Temp. measurement.
- Applications for Aquarium, Medical research, Agriculture, Fish hatcheries, Laboratory, Water conditioning, Mining industry, Schools & Colleges, Quality control.