A clamp meter will detect and measure a wide range of alternating or changing currents passing through a conductor under test. When telecommunications equipment is present, the value of leakage indicated by a clamp meter may be considerably more than that resulting from insulation impedance

Showing all 10 results

  • HIOKI CM-4001 Ac Leakage Clampmeter

    SPECIFICATIONS 

    • AC Current Range : 60.00 mA/ 600.0 mA/ 6.000 A/ 60.00 A/ 600.0 A, 5 ranges (40 Hz to 1 kHz, True RMS)
      Accuracy : (45-66 Hz): ±1.5% rdg ±5 dgt (60.00 mA to 6.000 A), ±2.5% rdg ±5 dgt (60.00 A to 600.0 A)
    • Frequency range : 40.0 Hz to 999.9 Hz
    • Crest factor : 4.5 (4000 counts or less)
      3 (more than 4000 counts, 6000 counts or less)
    • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
    • Display : Display refresh rate: 5 times/s
    • Core Jaw Diameter : φ 24 mm (0.94 in)
    • Dimensions : 37 mm (1.46 in) W × 160 mm (6.30 in) H × 27 mm (1.06 in) D
    • Mass : 115 g (4.1 oz.)
    • Included Accessories : Carrying case × 1, Strap × 1, Instruction manual × 1, Operating Precautions × 1, LR03 alkaline battery × 1

    FEATURES

    • Find issues faster with comparator function
    • Identify intermittent GFCI and RCD trips to prevent unplanned equipment downtime by testing for earth leakage current
    • Measure everything from leakage to load
    • Slim jaws let you work with ease
    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
    Read more
  • HIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function)

    SPECIFICATIONS 

    • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
      Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
      Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
      Defined Accuracy Range : 0.060 mA to 200.0 A
    • Frequency range : 15.0 Hz to 2000 Hz
    • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
    • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
    • Output Function : RMS (RMS value output), WAVE (waveform output)
    • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
      *Harmonics can be displayed with our free app GENNECT Cross.
    • Display : Display refresh rate: 5 times/s
    • Core Jaw Diameter : φ 40 mm (1.57 in.)
    • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
    • Mass : 400 g (14.1 oz.)
    • Included Accessories : Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2

    FEATURES

    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
    • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
    • Broad measurement range extending from leakage currents to load currents
    • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
    • Solve GFCI and RCD problems quickly
    • Speed up pass/fail judgments with the built-in comparator function
    • Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
    • External power supply: use an optional AC adapter for continuous, long-term measurement
    • CAT III 300 V
    Read more
  • HIOKI CM4002 AC LEAKAGE CLAMP METER

    SPECIFICATIONS 

    • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
      Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
      Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
      Defined Accuracy Range :  0.060 mA to 200.0 A
    • Frequency range : 15.0 Hz to 2000 Hz
    • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
    • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
    • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
      *Harmonics can be displayed with our free app GENNECT Cross
    • Core Jaw Diameter : φ 40 mm (1.57 in.)
    • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
    • Mass : 400 g (14.1 oz.)
    • Included Accessories : Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2

    FEATURES 

    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
    • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
    • CAT IV 300 V
      CAT III 600 V
    • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
    • Solve GFCI and RCD problems quickly
    • Broad measurement range extending from leakage currents to load currents
    • Speed up pass/fail judgments with the built-in comparator function
    Read more
  • HTC 4 Digit LCD Display Digital Clamp Meter CL-2055

    SPECIFICATIONS

    • DC VOLTAGE : 600V
    • AC VOLTAGE : 600V
    • DC CURRENT : 80~100A
    • AC CURRENT : 80~100A
    • RESISTANCE : 10kΩ

    FEATURES

    • 4 Digit LCD Display
    • 9999 Count
    • Sample Rate : 2 times / sec
    • Peak Hold
    • Low Power Indication
    • Auto Power Off (APO)

    SPECIAL FUNCTIONS

    • Continuity Buzzer <100 Ohm
    • MAX Test Voltage 3V DC
    • Overall Protection 600V rms
    • Standard Accessories : Manual Carrying Case, Test Lead
      Dimension : 202(H) x 70(W) x 30(D)mm
    • POWER: AAA 1.5V X 2
    Read more
  • HTC CL-2054 10uA high Resolution AC Leakage Current Tester 40mA ~ 100A

     Specification

    • AC Voltage: 400V
    • AC  Current: 40mA/400mA/4A/40A/80A/80-100A
    • Resistance Range: 40-400 Ohms
    • CONTINUITY TEST : Threshold 40Ω, Continuity Beeper 2.5KHz

    FEATURES

    • 3¾ Digit Manual Range
    • 3,999 Count
    • 10uA high Resolution
    • Auto Power Off (APO)
    • Shielded Transformer Jaw Open to 1.2”
    • POWER: 9V (6F22) X 1
    • Standarrd Accesories :Hard Carrying Case, Test Lead, Manual
    • Dimension : 209(H) x 43(W) x 30(D)mm
    Read more
  • LUTRON DL-6054 AC LEAKAGE TESTER

    SPECIFICATIONS

    • Current Range (AC) :  200mA – 200A
    • AC Current Resolution : 0.1mA – 0.1A
    • Current Accuracy (AC) : ± ( 1.2 % + 5d )
    • Jaw Opening Size : 19mm
    • Operating Temperature : 0˚C ~ 50˚C
    • Battery : 9V battery

    FEATURES

    • High precision AC mA measurement, it is useful for AC mA leakage current measurement.
    • Measure AC mA on the inductive conductor.
    • Miniature type, easy to carry out & operation.
    • High precision for low ACA leakage current measurement.
    • Built-in DATA HOLD function.
    • Crystal time base, high quality.
    • LCD display allows clear readout-out even at high ambient light level.
    • LSI circuit provides high reliability and durability.
    • Overload protection circuit is provided for all range.
    • Design to meet IEC 1010 safety requirement.
    • Compact, light weight and excellent operation.
    Read more
  • MECO 4671 A CLAMP-ON EARTH & LEAKAGE CURRENT TESTER

    SPECIFICATIONS : 

    • AC VOLTGE  : 0 – 400V
    • ACCURACY : ±1.5%
    • AC CURRENT : 0 – 40m/400m/4A/40A/80A/100A
    • ACCURACY : ±1.0%
    • RESISTANCE : 40 – 400 Ohms
    • RESISTANCE RESOLUTION : 0.1Ω

    FEATURES : 

    • 10µA Ultra High Resolution.
    • Large Conductor Diameter (30mm)
    • AC Current in 4 Ranges (20mA, 200mA, 2A, 60A)
    • Wide Frequency Response (40Hz-400Hz)
    • AC A, AC V, DC V.
    • Large 3½ Digit LCD (1999 Count)
    • Data Hold.
    • Low Battery Indication.
    Read more
  • MECO 4671 CLAMP – ON LEAKAGE CURRENT TESTERS

    SPECIFICATIONS :

    • DIMENSION : 210x62x35.6 mm
    • ACCESSORIES : Carrying Case x 1, Users Manual x 1, 1.5 V Battery x 2, Test Leads x 1 pair
    • POWER : 10 mA

    FEATURES : 

    • 10µA Ultra High Resolution
    • Large Conductor Diameter (30mm)
    • AC Current in 5 Ranges (40mA, 400mA, 4A, 40A, 60A)
    • Wide Frequency Response (40Hz-1KHz)
    • ACA, ACV, Ω and Continuity
    • Large 3¾ Digit LCD (4000 Count)
    • 40 Segment Fast Bargraph Display (20 times/sec.)
    • Data Hold and Max / Min Hold
    • Relative Measurement
    • 600 Vrms Overload Protection in Resistance Range
    Read more
  • MECO 4680 BL CLAMP – ON EARTH RESISTANCE TESTER

    SPECIFICATIONS : 

    • DIMENSION : 276x100x47 mm
    • DISPLAY : 4 Digit 9999 Counts LCD
    • ACCESSORIES : Resistance Calibration Plate x 1|9V Battery x 1|User Manual|Carry Bag x 1|Cleaning Brush x 1

    FEATURES : 

    • Model Number/Name: 4680 BLC.
    • Brand: Meco.
    • Jaw: 65 x 32 mm Approx.
    • Conductor Size: 65 mm x 32 mm.
    • Battery Type: 1.5V (AA) x 4 (Alkaline)
    • Display: 4 Digit 9999 counts LCD.
    • Memory: 99 Sets.
    • Range Selection: Auto.
    Read more
  • MECO 4680-BLC CLAMP – ON EARTH & LEAKAGE CURRENT TESTER

    SEPCIFICATIONS :

    • JAW OPENING  : 65 x 32 mm
    • RANGE  : AUTO
    • BATTERY TYPE : 1.5V (AA) x 4 (Alkaline)
    • DISPLAY : 4 Digit 9999 Counts LCD
    • MEMORY : 99 Sets
    • OVER LOADING INDICATION : OL
    • OPERATING ENVIRONMENT : -10°C ~ 55°C
    • DIMENSIONS : 293 x 90 x 66 mm
    • WEIGHT : 1250gms
    • CONFIGURABLE AlARM : Resistance : 1~199V, Current : 1~499mA

    FEATURES :

    • Non Contact Ground Resistance Measurement
    • No Auxiliary Electrodes Needed
    • Data Storing Memory
    • Data Hold, Noise Signal
    • Ground Resistance Measurement 0.01Ω ~ 1000Ω
    • Suitable for Earthing Strip of 65mm x 32mm
    • Leakage Current (0.5mA ~ 30.00A) (Model : 4680BLC)
    • Auto Ranging
    • Continuity Loop Test
    • Auto Power Off
    Read more