HIOKI FT-6031-50 Earth Tester
Read moreSPECIFICATIONS
- Measurement System : Two-electrode method/three-electrode method (switchable)
- Measurement range / Accuracy :
20 Ω (0 Ω〜20.00 Ω) / ±1.5% rdg ±8 dgt
200 Ω (0 Ω〜200.0 Ω) / ±1.5% rdg ±4 dgt
2000 Ω (0 Ω〜2000 Ω) / ±1.5% rdg ±4 dgt - Earth voltage : 0〜30.0 V rms
Accuracy : ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC) - Allowable earth potential : 25.0 V rms (DC or sine wave)
- Dustproof and waterproof : IP65/IP67 (EN60529)
- Dimensions : 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D
- Mass : 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories)
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Excellent noise resistance
- IP67 protected – top of the industry
- Minimize cabling time with innovative earthing rods and cable winder
- Wide 0Ω to 2000Ω measurement range
- Test all ground types from Class A to Class D with a single meter
-
HIOKI FT6380-50 Clamp On Earth Tester
Read moreSPECIFICATIONS
- Earth Resistance Range : 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω,
Accuracy: ±1.5 % rdg. ±0.02 Ω - AC Current Range : 20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA,
Accuracy: ±2.0 % rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less) - Maximum input current (Current measurement) : 100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50 Hz/60 Hz, requires derating at frequency)
- Maximum rated terminal-to-ground voltage : 600 VAC measurement category IV (anticipated transient overvoltage 8000 V)
- Memory Function : 2000 data
- Alarm Function : For resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold.
- Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross. - Other functions : Data hold, Backlight, Filter, Auto power save, Wireless communication (without Z3210 installed))
- Display : LCD, Max. 2,000 count Display refresh rate: Approx. 2 times/sec
- Dustproof and Waterproof : IP40 (EN60529) With Jaws Closed
- Power Supply : LR6 alkaline battery × 2
- Continuous Operating Time : Approx. 40 hours (25 Ω measurement, backlight off, without Z3210 installed)
Approx. 35 hours (25 Ω measurement, backlight off, with Z3210 installed and using wireless communications) - Maximum measurable conductor diameter : φ 32 mm (1.26 in)
- Dimensions : 73 mm (2.87 in) W × 218 mm (8.58 in) H × 43 mm (1.69 in) D
- Mass : 620 g (21.9 oz)
- Included Accessories : Carrying case, Resistance check loop (1 Ω±2%, 25Ω±1%), Strap, LR6 alkaline battery × 2, Instruction manual
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Measure load current up to 60.0 A range
- Clamp at the narrowest point
- Earth resistance measurement for multi-grounded systems
- Measure leak current with absolute certainty with highly sensitive 0.01 mA resolution (at 20.00 mA range)
Measurement Principle : Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated
Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value. - Earth Resistance Range : 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω,
-
HIOKI IR-3455 High Voltage Insulation Tester
Read moreSPECIFICATIONS
- Test Voltage : 250 V to 5.00 kV DC, (Possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kV)
- Measurement Range :
0.00 MΩ to 500 GΩ (250 V)
0.00 MΩ to 1.00 TΩ (500 V)
0.00 MΩ to 2.00 TΩ (1 kV)
0.00 MΩ to 5.00 TΩ (2.5 kV)
0.00 MΩ to 10.0 TΩ (5 kV) - Measurement Current : 1 mA (Test voltage 250 V to 1.00 kV), 0.5 mA (Test voltage 1.10 kV to 2.50 kV) 0.25 mA (Test voltage 2.60 kV to 5.00 kV), Short-circuit current: 2 mA or less
- Resistance Range : 10 MΩ to 10 TΩ, 7 ranges (auto range)
- Accuracy :
±5% rdg. ±5 dgt. Up to [Test voltage (setting value)/Resistance measurable at 100 nA]
±20% rdg. ±5 dgt. [Test voltage (setting value)/Resistance measurable at 100 nA] to [Test voltage (setting value)/Resistance measurable at 1 nA] or 500 GΩ
±30% rdg. ±50 dgt. [Test voltage (setting value)/Resistance measurable at 1 nA] or 501 GΩ to 9.99 TΩ - Leakage current measurement : 1.00 nA to 1.20 mA, 6 ranges (current measurement that occurs when test voltage is generated)
Accuracy ±2.5% rdg. ±5 dgt. (1 mA range); refer to complete catalog for other ranges - Voltage measurement : ±50 V to ±1.00 kV DC, 50 V to 750 V AC (50/60 Hz),
Accuracy: ±5 % rdg. ±5 dgt. , Input resistance: Approx. 10 MΩ - Temperature measurement : -10.0 ˚C to 70.0 ˚C, 3 ranges (used with optional sensor)
Accuracy ±1.0 ˚C (0.0 ˚C to 40.0 ˚C); refer to complete catalog for other ranges - Other Functions : Insulation Diagnosis (Temperature compensation, PI/DAR display, Step voltage test), Data memory, Communication (USB 2.0, PC application software), auto discharge, hot conductor warning indication, etc.
- Digital LCD, max. 999 dgt. with backlight, Bar graph display
- Dimensions and Mass : 260 mm (10.24 in)W × 250.6 mm (9.87 in)H × 119.5 mm (4.70 in)D, 2.8 kg (98.8 oz)
- Included Accessories : Test lead 9750-01 ×1, Test lead 9750-02 ×1, Test lead 9750-03 ×1, Alligator clip 9751-01 ×1, Alligator clip 9751-02 ×1, Alligator clip 9751-03 ×1, Instruction manual ×1, LR6 (AA) alkaline batteries ×6, USB cable ×1, PC application software (CD-R) ×1
FEATURES
- Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
- Wide testing voltage range, up to 5.00 kV from 250 V DC
- Wide measurement insulation range, up to 10 TΩ
- PI (Polarization Index) and DAR (Dielectric Absorption Ratio) automatically calculated / display
- Extended operating temperature range of -10°C to 50°C
- Data memory function to reduce handwritten notes
- Bright LED luminous scale
-
HIOKI P2000 DC High Voltage Probe
Read moreSPECIFICATIONS
- Maximum Input Voltage : DC 2000 V
- Maximum rated line-to-ground voltage
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V - Input Resistance : 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
- Overload Protection :
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) - Output Terminal : 4 mm banana terminal
- Operating Temperature Range : -25°C to 65°C (-13°F to 149°F)
- Operating Humidity Range : −25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing)
40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) - Storage temperature and humidity range : -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing)
- Standards : EN 61010
- Included Accessories : Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1
FEATURES
- Enables high voltage measurement up to CAT Ⅲ 2000 V
- Safely measure solar installations like the mega-solar without interrupting the grid
- Connects to compatible Hioki clamp meters and digital multimeters (DMMs)
ACCURACY FOR COMPATIBLE INSTRUMENTS
- DT-4261 :
Range 600.0 V: Combined accuracy ±0.5% rdg ±0.2 V
Range 2000 V: Combined accuracy ±0.5% rdg ±5 V - CM4141-50 ; CM4371-50 ; CM4373-50 ; CM4375-50 :
Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V
Range 2000 V: Combined accuracy ±1.0% rdg ±3 V - DT-4282 ; DT-4281 :
Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10) - DT-4252 ; DT-4253 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10) - DT-4255 ; DT-4256 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10)
-
HM AP-1 AquaPro Water Quality Tester (TDS)
Read moreSPECIFICATIONS
- TDS Range: 0-5000 ppm (mg/L)
- Temperature Range: 0-80 °C; 32-176 °F
- Resolution: 1 ppm
- Temperature Resolution: 0.1 °C/F
- Accuracy: ± 2%
- EC-to-TDS Conversion Factor: NaCl (avg. 0.5)
- Calibration: Digital calibration by push button.
- Housing: Water-resistant
- Power source: 1 x 3V button cell (included) (model CR2032)
- Dimensions: 15 x 2.8 x 1.3 cm (5.9 x 1.1 x .5 inches)
- Weight: 42.5 g (1.5 oz)
FEATURES
- Simultaneous TDS and Temperature reading
- Large easy to read screen
- Digital Calibration
- Water resistant housing
- Retail friendly packaging
- Automatic Temperature Compensation (ATC)
-
HM AP-2 AquaPro Water Quality Tester (EC)
Read moreSPECIFICATIONS
- EC Range: 0-9999 µS (µS/cm)
- Temperature Range: 0-80 °C; 32-176 °F
- Resolution: 1 µS; Temp. resolution is 0.1 °C/F
- Accuracy: ± 2%
- Calibration: Digital calibration by push button.
- Housing: Water-resistant
- Power source: 1 x 3V button cell (included) (model CR2032)
- Dimensions: 15 x 2.8 x 1.3 cm (5.9 x 1.1 x .5 inches)
- Weight: 42.5 g (1.5 oz)
FEATURES
- Simultaneous electrical conductivity (EC) and Temperature reading
- Large easy to read screen
- Digital Calibration (push button)
- Water resistant housing
- Retail friendly packaging
- Automatic Temperature Compensation (ATC)
- Factory Calibrated with a 700 µS solution
-
HM COM-100 Waterproof Professional Series EC/TDS Meter
Read moreSPECIFICATIONS
- EC Range : 0 – 9990 µS
- TDS Range : 0 – 8560 ppm (mg/L)
- Temperature Range: 0-80 °C; 32-176 °F
- Resolution :
EC: 0-99 : .1 µS; 100-999: 1 µS; 1000-9990: 10 µS
TDS: 0-99 : .1 ppm; 100-999: 1 ppm; 1000-9990: 10 ppm - Temperature : .1 °C/F
- Accuracy : +/- 2% F.S.
- EC to TDS Conversion Factor: Pre-programmed, non-linear conversions for KCl, 442TM or NaCl solutions, selected by the user.
- Temperature Compensation: Automatic (ATC) with three temperature coefficients
- Calibration: Digital calibration by push button.
- Auto shut-off: After 5 minutes
- 2 Probe: Detachable, with platinum electrodes
- Display : LCD panel
- Housing : Waterproof (submersible); floats
- Power source : 3 x 1.5V button cell batteries (included), model LR44
- Battery Life : Approximately 100 hours of usage (high ranges use greater power consumption)
- Dimensions : 18.5 x 3.4 x 3.4 cm (7.3 x 1.3 x 1.3 inches)
- Weight : 90.7g (3.2 oz) without case
FEATURES - Measures electrical conductivity (EC), total dissolved solids (TDS), salinity and temperature.
- UPGRADED: Four scales: µS, mS, ppm 0.5 (NaCl) Scale & 0.7 (442™) Scale
- Automatic Temperature Compensation (ATC) using three temperature coefficients
- Waterproof housing (IP-67 rating)
- Digital Calibration (push button) to any point within the meter’s range
- Auto-off function, data-hold function and low-battery indicator
- Display: large and easy-to-read LCD screen includes simultaneous temperature reading.
- Replaceable Sensor (model SP-C1)
- Factory Calibrated: The COM-100 meter is calibrated with a 1413 µS solution.
-
HM COM-360 Waterproof Professional Series pH/EC/TDS/Temp Meter
Read moreSPECIFICATIONS
- pH Range: 0.0 – 14.0 pH
- EC Range: 0 – 9990 μS; 0 – 9.99 mS
- TDS Range: 0 – 8560 ppm (mg/L); 0.5 (NaCl) scale; 0.7 (442) scale, 0 – 5000 ppm (mg/L)
- Temperature Range: 0.1 – 50°C; 32 – 122°F
- Accuracy: pH: ±0.1, EC/TDS: ±2%, Temp: ±1°C/°F
- EC-to-TDS Conversion Factor: Pre-programmed, non-linear conversions for 0.5 (NaCl) or 0.7 (442™) solutions, selected by the user
- Temperature Compensation: Automatic(ATC) to 25°C (ATC range: 1-50°C)
- Calibration: pH: Push Button Auto-calibration to 4, 7 or 10 pH for a fine tune digital calibration. EC/TDS: Digital calibration by push button (to any point within the range)
- Auto Shut-Off: After 5 minutes
- Probe: Detachable pH & TDS/EC Sensor
- Housing: water resistance (splash proof)
- Power source: 2 x AAA batteries
- Dimensions: 20.0 x 3.4 x 3.4 cm (7.8 x 1.3 x 1.3 inches)
- Weight: 110g (4.0 oz) with batteries
FEATURES
- Measures Potential Hydrogen (pH), Electrical Conductivity (EC), Total Dissolved Solids (TDS), and Temperature
- Five scales: pH, µS, mS, ppm 0.5 (NaCl) Scale & 0.7 (442™) Scale
- Automatic Temperature Compensation (ATC) using three temperature coefficients
- Water-resistant housing
- Digital Calibration (push button) to any point within the meter’s range
- Auto-off function, data-hold function, and low-battery indicator
- Display: large and easy-to-read LCD screen includes simultaneous temperature reading
- Replaceable Sensor (model SP-CP)
- Factory Calibrated (pH/EC/TDS)
- Includes translucent cap, 2 (AAA) alkaline batteries, pH 4 & 7 calibration solutions, pH storage solution and lanyard
- COM-360: One Year Limited Warranty
- Detachable Sensor (SP-P2): Six Month Limited Warranty.
-
HM COM-80 EC/TDS HydroTester Series
Read moreSPECIFICATIONS
- EC Range: 0 – 9990 µS; 0 – 9.9 mS
- TDS Range: 0 – 5000 ppm (0.5 Scale) ; 0-8560 ppm (0.7 Scale)
- Temperature Range: 1-80 °C; 33-176 °F
- Resolution: 1 µS/ppm; 0.1 mS
- Temp. Resolution: 0.1 °C/F
- Accuracy: +/- 2%
- Power source: 3 x 1.5V button cell batteries (LR44 or equivalent is included)
- Dimensions: 15.3 x 3.2 x 1.8 cm (6.0 x 1.3 x 0.7 inches)
- Weight: 53.9g (1.9 oz)
FEATURES
- Measures electrical conductivity (EC), total dissolved solids (TDS). Excellent for nutrient testing
- Four scales: EC: µS, mS; TDS: ppm, 0.5 (NaCl) & 0.7 (442™)
- Automatic Temperature Compensation (ATC)
- Water resistant
- Digital Calibration (push button) to any point within the meter’s range
- Auto-off function, data-hold function and low-battery indicator
- Display: large and easy-to-read LCD screen includes simultaneous temperature reading.
- Factory Calibrated: The COM-80 meter is calibrated with a 1413 µS solution.
- Includes a protective cap and batteries
-
HM PH-80 pH HydroTester Series
Read moreSPECIFICATIONS
- pH Range: 0 – 14
- Temperature Range: 1-55 °C; 32-130 °F
- Resolution: 0.1 pH; Temperature resolution is 0.1 °C/F
- Accuracy: +/- 0.2 pH; Temperature accuracy is +/-2%
- Calibration: Digital automatic calibration (one point)
- Minimum EC/TDS: 10 µS/5 ppm
- Electrode: Glass sensor and reference tube electrodes
- Power source: 3 x 1.5V button cell batteries (model LR44 or equivalent; included)
- Dimensions: 15.3 x 3.2 x 1.8 cm (6.0 x 1.3 x 0.7 inches)
- Weight: 53.9 g (1.9 oz)
FEATURES
- Measures pH and Temperature
- One-touch automatic digital calibration
- Water resistant
- Simultaneous temperature display
- Large LCD display
- Automatic Temperature Compensation (ATC)
- Auto-off function, data-hold function and low-battery indicator
- Factory Calibrated: The PH-80 meter is factory calibration to pH 7.0.
- Includes a translucent cap, batteries, storage solution and pH 7.0 buffer (powder)
-
HM TDS-3
Read moreSPECIFICATIONS
- TDS Range: 0 – 9990 ppm (mg/L)
- Temp. Range: 0 – 80°C
- Resolution: 0-999: 1 ppm; 1000-9990: 10 ppm (indicated by a ‘x10’ icon)
- Temperature Resolution: 0.1°C
- Accuracy: ±2% / Temp. ±1°C
- EC-to-TDS Conversion Factor: NaCl (avg. 0.5)
- ATC: Built-in sensor for Automatic Temperature Compensation of 1 to 50°C (33~122°F)
- Power source: 2 x 1.5V button cell batteries (included) (LR44 or equivalent)
- Battery life: 1000 hours of usage
- Dimensions: 15.5 x 3.1 x 2.3cm (6.1 x 1.25 x 1 inches)
- Weight with case: 76.5g (2.7 oz)
- Weight without case: 56.7g (2 oz)
FEATURES
- Hold Function
- Auto-off Function (After 10 min.)
- Built-in digital thermometer
- Includes a carrying case with belt clip
- Factory Calibrated with a 342 ppm NaCl solution. (Meter can be recalibrated with a mini-screwdriver).
-
HTC 360 TREB Analog Display Analog Multimeter
Read moreSPECIFICATIONS
- DC VOLTAGE : 0.1mV ~ 1000v 3; 1000V: 5 for 20kà / V
- AC VOLTAGE : 10V ~ 1000v 4; 1000V: 5 for 9kà / V
- DC CURRENT : 50μA ~ 10A 3; 10A: for 5
- RESISTANCE : 1 0.2Ã ~ 2kÃ
FEATURES
- Analog Multimeter with Mirror Scale
- Inbuilt Buzzer and LED
- Adjustable with x 100 Range
- Transistor Test, hFE with Diode
SPECIAL FUNCTIONS
- Diode Test
- Functional Protection
- Transistor Testing
- Continuity Buzzer About 100?
- Standard Accessories : Test Lead, Manual
- Dimension : 148(H) x 100(W) x 35(D)mm