Description | SPECIFICATIONS :
- DIMENSION : 276x100x47 mm
- DISPLAY : 4 Digit 9999 Counts LCD
- ACCESSORIES : Resistance Calibration Plate x 1|9V Battery x 1|User Manual|Carry Bag x 1|Cleaning Brush x 1
FEATURES :
- Model Number/Name: 4680 BLC.
- Brand: Meco.
- Jaw: 65 x 32 mm Approx.
- Conductor Size: 65 mm x 32 mm.
- Battery Type: 1.5V (AA) x 4 (Alkaline)
- Display: 4 Digit 9999 counts LCD.
- Memory: 99 Sets.
- Range Selection: Auto.
| SPECIFICATIONS
- DC VOLTAGE : 600V
- AC VOLTAGE : 600V
- DC CURRENT : 80~100A
- AC CURRENT : 80~100A
- RESISTANCE : 10kΩ
FEATURES
- 4 Digit LCD Display
- 9999 Count
- Sample Rate : 2 times / sec
- Peak Hold
- Low Power Indication
- Auto Power Off (APO)
SPECIAL FUNCTIONS
- Continuity Buzzer <100 Ohm
- MAX Test Voltage 3V DC
- Overall Protection 600V rms
- Standard Accessories : Manual Carrying Case, Test Lead
Dimension : 202(H) x 70(W) x 30(D)mm
- POWER: AAA 1.5V X 2
| SPECIFICATIONS
- AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
Accuracy : 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
Accuracy : 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt
Defined Accuracy Range : 0.060 mA to 200.0 A
- Frequency range : 15.0 Hz to 2000 Hz
- Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
- Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
- Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross
- Core Jaw Diameter : φ 40 mm (1.57 in.)
- Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
- Mass : 400 g (14.1 oz.)
- Included Accessories : Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
- CAT IV 300 V
CAT III 600 V
- Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
- Solve GFCI and RCD problems quickly
- Broad measurement range extending from leakage currents to load currents
- Speed up pass/fail judgments with the built-in comparator function
| Specification
- AC Voltage: 400V
- AC Current: 40mA/400mA/4A/40A/80A/80-100A
- Resistance Range: 40-400 Ohms
- CONTINUITY TEST : Threshold 40Ω, Continuity Beeper 2.5KHz
FEATURES
- 3¾ Digit Manual Range
- 3,999 Count
- 10uA high Resolution
- Auto Power Off (APO)
- Shielded Transformer Jaw Open to 1.2”
- POWER: 9V (6F22) X 1
- Standarrd Accesories :Hard Carrying Case, Test Lead, Manual
- Dimension : 209(H) x 43(W) x 30(D)mm
| SPECIFICATIONS
- AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
Accuracy : 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
Accuracy : 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt
Defined Accuracy Range : 0.060 mA to 200.0 A
- Frequency range : 15.0 Hz to 2000 Hz
- Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
- Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
- Output Function : RMS (RMS value output), WAVE (waveform output)
- Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
- Display : Display refresh rate: 5 times/s
- Core Jaw Diameter : φ 40 mm (1.57 in.)
- Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
- Mass : 400 g (14.1 oz.)
- Included Accessories : Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
- Broad measurement range extending from leakage currents to load currents
- Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
- Solve GFCI and RCD problems quickly
- Speed up pass/fail judgments with the built-in comparator function
- Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
- External power supply: use an optional AC adapter for continuous, long-term measurement
- CAT III 300 V
| SPECIFICATIONS
FEATURES
- High precision AC mA measurement, it is useful for AC mA leakage current measurement.
- Measure AC mA on the inductive conductor.
- Miniature type, easy to carry out & operation.
- High precision for low ACA leakage current measurement.
- Built-in DATA HOLD function.
- Crystal time base, high quality.
- LCD display allows clear readout-out even at high ambient light level.
- LSI circuit provides high reliability and durability.
- Overload protection circuit is provided for all range.
- Design to meet IEC 1010 safety requirement.
- Compact, light weight and excellent operation.
|
Content | Meco 4680B has the following features: Non Contact Ground Resistance Measurement; No Auxiliary Electrodes Needed; Recording / 116 Sets of Memory; Ground Resistance Measurement 0.025 ~ 1500 ; Suitable for Ground Wire upto 35mm (Model 4680B);Leakage Current (0.200mA ~ 35.00A)(Model 4680B); Programmable Data Logging; Auto Range; Continuity Loop Test; Auto Power Off | HTC 4 Digit LCD Display Digital Clamp Meter CL-2055 is a premium quality product from HTC. All HTC 4 Digit LCD Display Digital Clamp Meter CL-2055 are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture HTC 4 Digit LCD Display Digital Clamp Meter CL-2055, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. HTC products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of HTC Clamp Meters . | | HTC CL-2054 AC Leakage Current Tester is a premium quality product from HTC. All HTC CL-2054 AC Leakage Current Tester are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture HTC CL-2054 AC Leakage Current Tester, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. HTC products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of HTC Leakage Testers . | CM4002 AND CM4003 | Lutron DL-6054 ACA Leakage tester is a high precision AC mA measurement, it is useful for AC mA leakage current measurement. Measure ACMA on the inductive conductor. Measurement range: AC 200mA – 20A – 200.
Applications: Measures Ground fault current, Industrial troubleshooting, general AC load monitor, and medical device safety testing. |
Reviews