Description | SPECIFICATIONS
- Rated Voltage : 250 V / 500v / 1000v / 2500v / 5000v
- Accuracy : ±5%rdg±3dgt ±20%rdg (100GΩ or more)
- Short Circuit Current : 1.5mA
- Dimensions : 177 (L) × 226 (W) × 100 (D) mm / 300 (L) × 315 (W) × 125 (D) mm (Hard case)
- Weight : 3125A: 1.9kg approx. (including batteries) 4kg approx. (including accessories)
FEATURES
- Insulation Resistance up to 1TΩ
- Short-Circuit Current up to 1.5mA
- Wide Test Voltage from 250V to 5000V
- Diagnosis Function of PI and DAR
- Newly-designed alligator clip
- It comes with a tough hard case
- Filter function reduces noise interference for obtaining stable measurement
- Large display with Bar Graph indication and backlight
- Live voltage warning
- Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
| | SPECIFICATIONS :
- TEST VOLTAGE : 1000 V/ 2500 V/ 5000 V
- OPERATING TEMEPRATURE : 0 to 40 deg C
- DMENSIONS : 190x155x75 mm
- RESISTANCE : 0.1M Ohm to 200G Ohms
- ACCURACY : ±(3% +5 digit) for Insulation Resistance Range RDG
±(2% +5 digit) for AC Voltage Measurment
- AC VOLTAGE : 0 - 6000 VAC (50-60 Hz)
FEATURES :
- Data Holding Function.
- Display with Annunciators.
- Auto Range (Insulation Test).
- Battery Operated with AC Adaptor.
- With LED Indicators & Beep Facility.
- Red LED Indicator for HV (High Voltage).
- Measurement of AC Voltage Upto 600VAC.
- Range Selection & Single Person Push Button Operation.
- LCD with Green Back Light Function with Indicator Switch.
- Measurement of Phase Sequence Between (Phase - Phase Voltage).
- Inbuilt Protection Circuit to prevent the harm of reverse Voltages.
| SPECIFICATIONS
DC VOLTAGE
- RANGE : ±30~±600V
- RESOLUTION : 1V
- ACCURACY : ±2.0% of rdg + 3 digits
AC VOLTAGE
- RANGE : 30~600V (50/60Hz)
- RESOLUTION : 1V
- ACCURACY : ±2.0% of rdg + 3 digits
INSULATION RESISTANCE MEASUREMENT
- Output Voltage : 500V
- Display Range : 0.0MΩ~20GΩ
- Open Circuit Voltage : DC 500V 0% – +20%
- Test Current : 1mA-1.2mA @ 500KΩ
- Accuracy : 0.0~99.9MΩ ± 3% of rdg + 5 digits ; 100MΩ~9.99GΩ ± 5% of rdg + 5 digits ; 10.0~20.0GΩ ± 10% of rdg + 5 digits
- Short Circuit :Maximum than 2.0mA
- Output Voltage : 1000V
- Display Range : 0.0MΩ~40GΩ
- Open Circuit Voltage : DC 1000V 0% – +20%
- Test Current : 1mA-1.2mA @ 1MΩ
- Accuracy : 0.0~99.9MΩ ± 3% of rdg + 5 digits ; 100MΩ~9.99GΩ ± 5% of rdg + 5 digits ; 10.0~20.0GΩ ± 10% of rdg + 5 digits
- Short Circuit :Maximum than 2.0mA
- Output Voltage : 2500V
- Display Range : 0.0MΩ~100GΩ
- Open Circuit Voltage : DC 2500V 0% – +20%
- Test Current : 1mA-1.2mA @ 2.5MΩ
- Accuracy : 0.0~99.9MΩ ± 3% of rdg + 5 digits ; 100MΩ~9.99GΩ ± 5% of rdg + 5 digits ; 10.0~20.0GΩ ± 10% of rdg + 5 digits
- Short Circuit :Maximum than 2.0mA
- Output Voltage : 5000V
- Display Range : 0.0MΩ~1000GΩ
- Open Circuit Voltage : DC 5000V 0% – +20%
- Test Current : 1mA-1.2mA @ 5MΩ
- Accuracy : 0.0~99.9MΩ ± 3% of rdg + 5 digits ; 100MΩ~9.99GΩ ± 5% of rdg + 5 digits ; 10.0~20.0GΩ ± 10% of rdg + 5 digits
- Short Circuit :Maximum than 2.0mA
FEATURES
- Polarization Index (PI)
- Dielectric Absorption (DAR)
- USB Interface
- Over Range Warning
- High Voltage Indication
- POWER: 1.5V X 8
- Standard Accessories : Test Lead, USB Cable & Software, Power Adaptor
- Dimension : 505(H) x 345(W) x 345(D)mm
| SPECIFICATIONS
- AC/DC Voltage Measurement
Range : 600.0 V
Resolution : 0.1V
Accuracy : 50 Hz to 400 Hz ±(% of Rdg + Digits) ±(2% + 3)
- Earth Bond Resistance Measurement
Range : 20.00 Ω to 20.00 kΩ
Resolution : 0.01 Ω to 0.01 kΩ
Accuracy : ±(1.5% + 3)
- Insulation Specifications
Range : 0.01 MΩ to 2000 MΩ
Test Voltage : 500 V, 1000 V
Test Voltage Accuracy : + 20%, - 0%
- Storage temperature : -40°C to 60°C (-40°F to 140°F)
- Operating temperature : -20°C to 55°C (-4°F to 131°F)
- Vibration : Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
- Safety : Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
- Certifications : CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
- Size : 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
- Weight : 550g
- IP Rating : IP40
FEATURES
- A rugged, compact insulation resistance tester for residential and commercial electricians
- Performs insulation tests from 0.01 MΩ to 2000 MΩ
- Offers two insulation test voltages: 500 V and 1000 V
- Includes live circuit detection to prevent insulation test if voltage >30 V is detected
- Measures resistance from 0.01 Ω to 20.00 kΩ
| SPECIFICATIONS
- Testing Voltage : 100/250/500/1000/2500/5000 V
- OUT VOLTAGE : 90~110% of the test voltage
- RANGE : 0.1M 20G for 100/250/500 V ; 0.1M 200G for 1000/2500/5000 V
- RESOLUTION : 0.01MΩ
- ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 10 digits ; 10~200GΩ ± 10% of rdg + 5 digits
AC VOLTAGE
-
- RANGE : 0 – 600V
- RESOLUTION : 1V
- ACCURACY : ±2.0% of rdg + 5 digits
FEATURES
- 3½ Digit Insulation Tester with Backlight
- 1,999 Count
- Data Hold
- Test Range 100 V to 5000 V
- POWER: AA 1.5V X 8 (Rechargeable Battery)
- Standard Accessories : Soft Carrying Case, Test Lead, Manual, Power Adaptor,AA 1.5V X 8 (Rechargeable Battery)
- Dimension : 190(H) x 155(W) x 75(D)mm
|
Content | Kyoritsu High Voltage Insulation Tester 250-5000V KEW-3125A is a premium quality product from KyoritsuDSF. All Kyoritsu High Voltage Insulation Tester 250-5000V KEW-3125A are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture Kyoritsu High Voltage Insulation Tester 250-5000V KEW-3125A, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. Kyoritsu products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of Kyoritsu Insulation Testers. | MECO DIT-99A Digital Insulation Tester has the following features: 3 Digit 17mm LCD Display; High Accuracy (3% rdg + 2 dgt); Single Person Push Button Operation; Designed to Generally Conform to IS 10656-1983; Meets Requirement of IEC1010 Installation Category II 100V Phase Earth; Terminal Voltage : >85% of Rated Voltage for Insulation; Resistance Measurement from10% to 100% of the Insulation Resistance Range; Carrying Case | MECO DIT-954 Digital Insulation Tester has the following features: 3 1/2 Digit (1999 Counts) Lage LCD Display; High Accuracy; Range Selection & Single Person Push Button Operation; LCD Back Light Function with Indicator Switch; Data Holding Function Function Icons on Display; Measurement of AC Voltage upto 600VAC; Measurement of Phase Sequence between (Phase-Phase Voltage)with LED Indicator; Auto Range (Insulation Test); LED Indicator for High Voltage; Inbuilt Protection Circuit to prevent the harm of reverse voltages; Battery Operated with AC Adaptor; 3 Ranges of Voltage & Insulation Resistance | HTC LCD Display Digital Insualtion Tester 7250IN is a premium quality product from HTC. All HTC LCD Display Digital Insualtion Tester 7250IN are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture HTC LCD Display Digital Insualtion Tester 7250IN, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. HTC products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of HTC Insulation Testers . | The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing. | |
Reviews
There are no reviews yet.