HTC 6250IN Digital Insulation Tester IRT Range 0.1M- 200G Ohm

Availability: In Stock

SPECIFICATIONS

  • Testing Voltage : 1000/2500/5000V
  • OUT VOLTAGE : 90~110% of the test voltage
  • RANGE : 0.1MΩ~200GΩ
  • RESOLUTION : 0.01MΩ
  • ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 5 digits ; 10~200GΩ ± 10% of rdg + 5 digits

AC VOLTAGE

    • RANGE : 0 – 600V
    • RESOLUTION : 1V
    • ACCURACY : ±2.0% of rdg + 5 digits

FEATURES

  • 3½ Digit Insulation Tester with Backlight
  • 1,999 Count
  • Data Hold
  • Auto Ranging
  • 3 in 1 Insulation Resistance Phase Testing / Voltage Testing & Adaptor
  • POWER: AA 1.5V X 8
  • Standard Accessories : Hard Carrying Case, Test Lead, Manual, Power Adaptor
  • Dimension : 190(H) x 155(W) x 75(D)m

Description

HTC 6250IN Digital Insulation Tester IRT Range 0.1M- 200G Ohm. This digital insulation tester is the perfect tool for professional electricians. It has a large, easy-to-read LCD display that clearly shows the insulation resistance value. It’s also lightweight and fits easily in your toolbox. The quality is excellent, and the price is fit for your budget. The tester has a range of features that make it ideal for testing a variety of insulation types

Reviews

There are no reviews yet.

Be the first to review “HTC 6250IN Digital Insulation Tester IRT Range 0.1M- 200G Ohm”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHTC 6250IN Digital Insulation Tester IRT Range 0.1M- 200G Ohm removeRish Insu-10 Analog - Digital Insulation and Continuity Tester removeHTC DIT-90 Digital Insulation Tester removeMECO DIT 954 DIGITAL INSULATION TESTER removeRishabh AIT 501 Smart 5KV Digital Insulation Tester removeMECO DIT99BL-A DIGITAL INSULATION TESTER remove
NameHTC 6250IN Digital Insulation Tester IRT Range 0.1M- 200G Ohm removeRish Insu-10 Analog - Digital Insulation and Continuity Tester removeHTC DIT-90 Digital Insulation Tester removeMECO DIT 954 DIGITAL INSULATION TESTER removeRishabh AIT 501 Smart 5KV Digital Insulation Tester removeMECO DIT99BL-A DIGITAL INSULATION TESTER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS
  • Testing Voltage : 1000/2500/5000V
  • OUT VOLTAGE : 90~110% of the test voltage
  • RANGE : 0.1MΩ~200GΩ
  • RESOLUTION : 0.01MΩ
  • ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 5 digits ; 10~200GΩ ± 10% of rdg + 5 digits
AC VOLTAGE
    • RANGE : 0 – 600V
    • RESOLUTION : 1V
    • ACCURACY : ±2.0% of rdg + 5 digits
FEATURES
  • 3½ Digit Insulation Tester with Backlight
  • 1,999 Count
  • Data Hold
  • Auto Ranging
  • 3 in 1 Insulation Resistance Phase Testing / Voltage Testing & Adaptor
  • POWER: AA 1.5V X 8
  • Standard Accessories : Hard Carrying Case, Test Lead, Manual, Power Adaptor
  • Dimension : 190(H) x 155(W) x 75(D)m
SPECIFICATIONS
  • Temperature Coefficient : <0.1% per °C
  • Operating Temperature :  -20°C To +40°C (full range)  -20°C To +60°C (upto 100M )
  • Storage Temperature :  -25°C To +65°C
  • Relative Humidity : 90% RH at 40°C max.
  • Display : LCD display Field  (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functions
  • Dimensions :  84 mm x 195 mm x 35 mm
  • Weight : 500 g including battery
FEATURES
  •  Test Voltages 50V/ 100V/ 250V,/500V /1000V : Test voltages from 50V to 1000V can be selected for Insulation Resistance measurement .It covers all insulation tests up to 1000V
  •  Insulation Resistance measurement: The instrument is capable of measuring insulation resistance from 10 K ...999 M Ohm
  •  Hands-free continuity testing: Continuity testing (0-10 W with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
  •  Voltmeter: Instrument measures voltages >25V …600V AC/DC
  •  Automatic discharge for capacitive circuits after test measurement: Capacitive devices under test, such as cables and windings, that get charged during the test, are discharged by the tester.
  •  Live circuit detection: Displays presence of voltages  25V irrespective of function selected.
  •  Pre-selectable limit checks (Go / No-Go option) for MW/GW An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
  •  Lead resistance null facility: The instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances.
  •  Storage of MIN / MAX values In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored
  •  Storage Memory for last 10 readings. The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, Continuity and Resistance measurement.
  •  Blown fuse indication. The display FUSE points to a blown fuse.
  •  Low battery indication. Automatic display of the Symbol “ ” when battery cells are exhausted.
  •  Stop Watch. : This function allows you to measure elapsed time up to 1 hour.
  •  Auto-power off function : The instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation.
  •  Protective holster for rough duty . A holster of soft rubber with tilt stand protects the meter against damage in the case of shock and drop
SPECIFICATIONS DIT 90 A
  • VOLTAGE : 1000
  • RANGE : 2000 MΩ
  • RESOLUTION : 1 MΩ
  • ACCURACY : 2 mA±3%of rdg + 2 digits
  • MAXIMUM NO LOAD VOLTAGE : ±25% of rated voltage
DIT 90 B
  • VOLTAGE : 1000
  • RANGE : 200 MΩ
  • RESOLUTION : 0.1 MΩ
  • ACCURACY : 2 mA±3%of rdg + 2 digits
  • MAXIMUM NO LOAD VOLTAGE : ±25% of rated voltage
DIT 90 C
  • VOLTAGE : 500
  • RANGE : 1000 MΩ
  • RESOLUTION : 1 MΩ
  • ACCURACY : 2 mA±3%of rdg + 2 digits
  • MAXIMUM NO LOAD VOLTAGE : ±25% of rated voltage
DIT 90 D
  • VOLTAGE : 500
  • RANGE : 200 MΩ
  • RESOLUTION : 0.1 MΩ
  • ACCURACY : 2 mA±3%of rdg + 2 digits
  • MAXIMUM NO LOAD VOLTAGE : ±25% of rated voltage
DIT 90 E
  • VOLTAGE : 100
  • RANGE : 200 MΩ
  • RESOLUTION : 0.1 MΩ
  • ACCURACY : 2 mA±3%of rdg + 2 digits
  • MAXIMUM NO LOAD VOLTAGE : ±25% of rated voltage
FEATURES
  • 3½ Digit
  • Optional Power Adaptor
  • 5 Models with Various Voltage and Mohm Range
  • Single Person Push Button Operation
  • POWER: AA 1.5V X 6
  • Standard Accessories : Soft Carrying Case, Test Lead, Manual
  • Dimension : 139(H) x 99(W) x 54(D)mm
SPECIFICATIONS : 
  • TEST VOLTAGE : 1000 V/ 2500 V/ 5000 V
  • OPERATING TEMEPRATURE : 0 to 40 deg C
  • DMENSIONS : 190x155x75 mm
  • RESISTANCE : 0.1M Ohm to 200G Ohms
  • ACCURACY : ±(3% +5 digit) for Insulation Resistance Range RDG
                          ±(2% +5 digit) for AC Voltage Measurment
  • AC VOLTAGE :  0 - 6000 VAC (50-60 Hz)
FEATURES : 
  • Data Holding Function.
  • Display with Annunciators.
  • Auto Range (Insulation Test).
  • Battery Operated with AC Adaptor.
  • With LED Indicators & Beep Facility.
  • Red LED Indicator for HV (High Voltage).
  • Measurement of AC Voltage Upto 600VAC.
  • Range Selection & Single Person Push Button Operation.
  • LCD with Green Back Light Function with Indicator Switch.
  • Measurement of Phase Sequence Between (Phase - Phase Voltage).
  • Inbuilt Protection Circuit to prevent the harm of reverse Voltages.
   
SPECIFICATIONS
  • Test Voltages : 500V, 1000V, 2500V, 5000V
  • Test Voltage Accuracy : 0% to 20%
  • 500V Range (Accuracy) : 1MOhm to 20GOhm (± 3%+5)
  • 1000V Range (Accuracy) : 2MOhm to 40GOhm (± 3%+5)
  • 2500V Range (Accuracy) : 5MOhm to 100GOhm (± 3%+5)
  • 5000V Range (Accuracy) : 10MOhm to 1000GOhm (± 3%+5)
  • Short Circuit Current : 1.8 mA
  • AC/ DC Voltage : 600V
  • Low Resistance : 0.1Ohm to 999.9Ohm
  • Operating Temperature : -10 to 40 °C
  • Storage Temperature : -20 to 60° C
  • Relative humidity : 85% @ -10 °C to 40 °C
  • Dimensions  : 202 x 155 x 94 mm
  • LCD Size  : 123mm x 58mm
  • Net Weight: Approx. 2kg (including battery)
FEATURES
  • Robust unit
  • Test voltages of 500V, 1000V, 2500V and 5000V & Insulation Resistance measurement upto 1 T Ohm
  • Automatic Polarisation Index (PI), Dielectric Absorption Ratio (DAR)
  • DC/AC voltage measurements to 600V
  • Autoranging insulation resistance tester
  • Auto shut down when left idle & Optional Operation on Mains via adapter
  • Datalogging capabilities and USB interface
  • Comparator Function
  • Wide LCD with backlit screen, Analog bar graph (30 segment)
ContentHTC 6250IN Digital Insulation Tester IRT Range 0.1M- 200G Ohm. This digital insulation tester is the perfect tool for professional electricians. It has a large, easy-to-read LCD display that clearly shows the insulation resistance value. It's also lightweight and fits easily in your toolbox. The quality is excellent, and the price is fit for your budget. The tester has a range of features that make it ideal for testing a variety of insulation typesRISH Insu10 Analog-Digital Insulation and Continuity Tester is suitable for following Measurement of the insulation resistance on electrically dead equipment and systems with test voltages up to 1000V. For testing motors, transformers, generators, switchgears. For testing of house hold appliances. Measurement of the insulation resistance of cables. Very useful for on-site maintenance and service departmentsHTC DIT-90C Digital Insulation Tester Resistance range 0-1000M Ohm is a premium quality product from HTC. All HTC DIT-90 Digital Insulation Tester Resistance range 200-2000M Ohm are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture HTC DIT-90 Digital Insulation Tester Resistance range 200-2000M Ohm, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. HTC products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of HTC Insulation Testers .MECO DIT-954 Digital Insulation Tester has the following features: 3 1/2 Digit (1999 Counts) Lage LCD Display; High Accuracy; Range Selection & Single Person Push Button Operation; LCD Back Light Function with Indicator Switch; Data Holding Function Function Icons on Display; Measurement of AC Voltage upto 600VAC; Measurement of Phase Sequence between (Phase-Phase Voltage)with LED Indicator; Auto Range (Insulation Test); LED Indicator for High Voltage; Inbuilt Protection Circuit to prevent the harm of reverse voltages; Battery Operated with AC Adaptor; 3 Ranges of Voltage & Insulation ResistanceThe Agam AIT 501 is the compact insulation resistance tester with diagnostic features like PI, DAR. When carrying out insulation resistance measurements this device uses test voltages of 500V, 1000V, 2500V and 5000V. At 500V this tester can carry out insulation resistance measurements from 1MOhms to 20GOhms, it carries out this measurement at 5MOhms to 1000GOhms. The tester can also be used to carry out AC/DC voltage measurements  and low resistance testing . The AIT 501 is an autoranging device and will automatically choose the applicable range depending on the test. It also includes a large, backlit LCD screen, auto power down function when left idle and includes a USB interface for using the tester to download data to PC. To accompany USB connectivity the AIT 501 also includes datalogging capabilities. When displaying testing results the AIT 501 uses both numerical and analogue bar graph representation of the test results. It also allows users to carry out comparisons, polarisation index calculations and dielectric absorption calculations. This insulation resistance tester is CAT III 600V, EN 61010-1 and EN 61326-1 compliant.. An ideal tool for Insulation testing designed smartly.MECO DIT-99A Digital Insulation Tester has the following features: 3 Digit 17mm LCD Display; High Accuracy (3% rdg + 2 dgt); Single Person Push Button Operation; Designed to Generally Conform to IS 10656-1983; Meets Requirement of IEC1010 Installation Category II 100V Phase Earth; Terminal Voltage : >85% of Rated Voltage for Insulation; Resistance Measurement from10% to 100% of the Insulation Resistance Range; Carrying Case
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information