SELEC VFD-L-1-005-230V / VFD-L-1-010-230V
SPECIFICATIONS
- AC Input Voltage Range : Single Phase: 230V
- Frequency Range : 50Hz/60Hz
- Control Mode : Scalar Control Based Space Vector PWM
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0.0 – 999.9 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
- Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
- Ingress Protection : IP20
- Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
- Output Current :
VFD-L-1-005-230V : 2.5A
VFD-L-1-010-230V : 5A
FEATURES
- 4 Pre-set V/F mode; 1 user defined V/F Program
- Input: Single phase 230V, 50Hz/60Hz
- Output: Three phase 230VAC, 0-400Hz
- Output Power: 0.5 HP/0.4KW & 1HP/0.75KW
- 4 (PNP/NPN) Inputs, 2 Analog Inputs(POT/0-10V;0-20mA/4-20mA), 1 Relay Output
- HMI with 5 keys, Potentiometer 4×7 segment with 4 LED display
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over Temperature, Overload and Under current, System error
- Suitable for application like Pumps, Fans, Conveyor, Food ; drink packaging machinery, Industrial washing machine and most general industries etc
-
SELEC VFD-S-1-010-230V / VFD-S-1-020-230V
SPECIFICATIONS
- AC Input Voltage Range : Single Phase: 230V
- Frequency Range : 50Hz/60Hz
- Control Mode : Scalar Control Based Space Vector PWM
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
- Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
- Ingress Protection : IP20
- Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
- Output Current :
VFD-S-1-010-230V : 5A
VFD-S-1-020-230V : 7A
FEATURES
- 4 Pre-set V/F; 1 user defined V/F Program
- Input: Single phase 230V, 50Hz/60Hz
- Output: Three phase 230VAC, 0-400Hz
- Output power: 0.5 HP/0.4KW TO 2HP/1.5 KW
- 5 (PNP/NPN) Inputs, 1 POT Input, 1 Analog Inputs(0-10V/0-20mA/4-20mA), 1 Relay Output, 1 Analog Output(0-10V/0-20mA); 1 Open collector output
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over Temperature, Overload and Under current, System error.
- Suitable for application like Pumps, Fans, Conveyor, Food; drink packaging machinery, Industrial washing machine and most general industries etc
-
SELEC VFD-S-3-010-415V / VFD-S-3-030-415V
SPECIFICATIONS
- AC Input Voltage Range : Three Phase: 450V
- Frequency Range : 50Hz/60Hz
- Control Mode : Space Vector PWM Based Scalar Control
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
- Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
- Ingress Protection : IP20
- Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
- Output Current :
VFD-S-1-010-230V : 2.5A
VFD-S-1-020-230V : 5.1A
FEATURES
- 4 Pre-set V/F mode & 1 user defined V/F Program
- Input: Three phase 230V/415V, 50Hz/60Hz
- Output power: 1 HP/0.75KW to 25HP/18.5KW
- 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
- Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc
-
SELEC VFD-SN-3-075-B-415V
SPECIFICATIONS
- AC Input Voltage Range : Three Phase : 415V
- Frequency Range : 50Hz/60Hz
- Control Mode : Space Vector PWM Based Scalar Control
- Frequency Control Range : 0.1~400 Hz
- Acc./Dec. Time : 0-3600 sec., 4 acceleration and deceleration time setting available
- Overload Capacity : Over current, Over voltage, Under voltage, Over Temperature, Overload, Under current, System error.
- Ingress Protection : IP20
- Working Temperature : -10°C ~ +55°C , Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
FEATURES
- 4 Pre-set V/F mode & 1 user defined V/F Program
- Input: Three phase 230V/415V, 50Hz/60Hz
- Output power: 1 HP/0.75KW to 25HP/18.5KW
- 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
- Supports RS485 Modbus Communication protocol
- Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
- Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc