Showing all 4 results

  • SELEC VFD-L-1-005-230V / VFD-L-1-010-230V

    SPECIFICATIONS 

    • AC Input Voltage Range : Single Phase: 230V
    • Frequency Range : 50Hz/60Hz
    • Control Mode : Scalar Control Based Space Vector PWM
    • Frequency Control Range : 0.1~400 Hz
    • Acc./Dec. Time : 0.0 – 999.9 sec., 4 acceleration and deceleration time setting available
    • Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
    • Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
    • Ingress Protection : IP20
    • Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
    • Output Current :
      VFD-L-1-005-230V : 2.5A
      VFD-L-1-010-230V : 5A

    FEATURES 

    • 4 Pre-set V/F mode; 1 user defined V/F Program
    • Input: Single phase 230V, 50Hz/60Hz
    • Output: Three phase 230VAC, 0-400Hz
    • Output Power: 0.5 HP/0.4KW & 1HP/0.75KW
    • 4 (PNP/NPN) Inputs, 2 Analog Inputs(POT/0-10V;0-20mA/4-20mA), 1 Relay Output
    • HMI with 5 keys, Potentiometer 4×7 segment with 4 LED display
    • Supports RS485 Modbus Communication protocol
    • Provides protection against Over current, Over Voltage, Under Voltage, Over Temperature, Overload and Under current, System error
    • Suitable for application like Pumps, Fans, Conveyor, Food ; drink packaging machinery, Industrial washing machine and most general industries etc
    Read more
  • SELEC VFD-S-1-010-230V / VFD-S-1-020-230V

    SPECIFICATIONS

    • AC Input Voltage Range : Single Phase: 230V
    • Frequency Range : 50Hz/60Hz
    • Control Mode : Scalar Control Based Space Vector PWM
    • Frequency Control Range : 0.1~400 Hz
    • Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
    • Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
    • Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
    • Ingress Protection : IP20
    • Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
    • Output Current :
      VFD-S-1-010-230V : 5A
      VFD-S-1-020-230V : 7A

    FEATURES

    • 4 Pre-set V/F; 1 user defined V/F Program
    • Input: Single phase 230V, 50Hz/60Hz
    • Output: Three phase 230VAC, 0-400Hz
    • Output power: 0.5 HP/0.4KW TO 2HP/1.5 KW
    • 5 (PNP/NPN) Inputs, 1 POT Input, 1 Analog Inputs(0-10V/0-20mA/4-20mA), 1 Relay Output, 1 Analog Output(0-10V/0-20mA); 1 Open collector output
    • Supports RS485 Modbus Communication protocol
    • Provides protection against Over current, Over Voltage, Under Voltage, Over Temperature, Overload and Under current, System error.
    • Suitable for application like Pumps, Fans, Conveyor, Food; drink packaging machinery, Industrial washing machine and most general industries etc
    Read more
  • SELEC VFD-S-3-010-415V / VFD-S-3-030-415V

    SPECIFICATIONS

    • AC Input Voltage Range : Three Phase: 450V
    • Frequency Range : 50Hz/60Hz
    • Control Mode : Space Vector PWM Based Scalar Control
    • Frequency Control Range : 0.1~400 Hz
    • Acc./Dec. Time : 0.0 – 3600.0 sec., 4 acceleration and deceleration time setting available
    • Overload Capacity : 150% for 1min, 180% for 10sec, 200% for 1sec.
    • Protection functions : Over current, Over voltage, Under voltage, Over heat, Overload, Under current, System error
    • Ingress Protection : IP20
    • Working Temperature : 10~55 Degree Celsius, Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level
    • Output Current :
      VFD-S-1-010-230V : 2.5A
      VFD-S-1-020-230V : 5.1A

    FEATURES

    • 4 Pre-set V/F mode & 1 user defined V/F Program
    • Input: Three phase 230V/415V, 50Hz/60Hz
    • Output power: 1 HP/0.75KW to 25HP/18.5KW
    • 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
    • Supports RS485 Modbus Communication protocol
    • Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
    • Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc
    Read more
  • SELEC VFD-SN-3-075-B-415V

    SPECIFICATIONS

    • AC Input Voltage Range : Three Phase : 415V
    • Frequency Range : 50Hz/60Hz
    • Control Mode : Space Vector PWM Based Scalar Control
    • Frequency Control Range : 0.1~400 Hz
    • Acc./Dec. Time : 0-3600 sec., 4 acceleration and deceleration time setting available
    • Overload Capacity : Over current, Over voltage, Under voltage, Over Temperature, Overload, Under current, System error.
    • Ingress Protection : IP20
    • Working Temperature : -10°C ~ +55°C , Humidity : <90%, No condensation, IP20, Indoor, <1000m altitude above sea level

    FEATURES

    • 4 Pre-set V/F mode & 1 user defined V/F Program
    • Input: Three phase 230V/415V, 50Hz/60Hz
    • Output power: 1 HP/0.75KW to 25HP/18.5KW
    • 8 (PNP/NPN) Inputs, 2 Analog Inputs(0-10V/0-20mA/4-20mA), 2 Relay Output, 1 Analog Output(0-10V/0-20mA); 2 Open collector output
    • Supports RS485 Modbus Communication protocol
    • Provides protection against Over current, Over Voltage, Under Voltage, Over heat, Overload and Under current, System error.
    • Suitable for application like Pumps, Fans, Conveyor, Food & drink packaging machinery, Industrial washing machine and most general industries etc
    Read more