MECO-G R-DIT945K-1 DIGITAL INSULATION TESTER 100/250/500/1000/2500/5000V
SPECIFICATIONS
- Test Voltage : 100V/250V/500V ±10%
Range : 0.1~20MΩ
Accuracy : ±(3% + 5dgts)
Resolution : 0.01MΩ - Test Voltage : 1000V/2500V/5000VDC ±10%
Range : 200MΩ~10GΩ
Accuracy : ±(5% + 10dgts)
Resolution : 0.01MΩ - Display : 3½ Dgt. (1999 Counts) Large LCD Display with 29mm Display Height.
- Accuracy : ±(3% + 5dgts)
- Operating Temperature : 0°C to 40°C (RH £ 85%)
- Storage Temperature : -10°C to 50°C (RH £ 75%)
- Dimensions : 190 x 155 x 75 mm
- Weight : Approx 900g
- Power : 12V (8 x 1.5V) (R6AA size batteries) or AC Adaptor 12VDC
FEATURES
- 3½ Digit (1999 Counts) Large Display with Back light
- LED Indicator for HV (High Voltage)
- High Accuracy ±(3% + 2dgts) for Insulation Measurement.
- In-build Protection Circuit to prevent the damage reverse voltages .
- LCD Back Light Function with Indicator Switch.
- Battery Operated / AC adapter
- 6 Ranges of Insulation Measurement.
- Display with Annunciators
- Suitable for calculation PI and DAR (manually)
- Auto-Ranging (Insulation Measurement)
- As per IS10656-1983
- As per EMC standard IEC 61326-1 Class B
- Over Voltage CAT III, 600V
- AS per Safety Standard IEC/EN 61010-1 & 61010-31
- IP-44 Protection
- Test Voltage : 100V/250V/500V ±10%
-
Rish Insu-10 Analog – Digital Insulation and Continuity Tester
SPECIFICATIONS
- Temperature Coefficient : <0.1% per °C
- Operating Temperature : -20°C To +40°C (full range) -20°C To +60°C (upto 100M )
- Storage Temperature : -25°C To +65°C
- Relative Humidity : 90% RH at 40°C max.
- Display : LCD display Field (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functions
- Dimensions : 84 mm x 195 mm x 35 mm
- Weight : 500 g including battery
FEATURES
- Test Voltages 50V/ 100V/ 250V,/500V /1000V : Test voltages from 50V to 1000V can be selected for Insulation Resistance measurement .It covers all insulation tests up to 1000V
- Insulation Resistance measurement: The instrument is capable of measuring insulation resistance from 10 K …999 M Ohm
- Hands-free continuity testing: Continuity testing (0-10 W with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
- Voltmeter: Instrument measures voltages >25V …600V AC/DC
- Automatic discharge for capacitive circuits after test measurement: Capacitive devices under test, such as cables and windings, that get charged during the test, are discharged by the tester.
- Live circuit detection: Displays presence of voltages 25V irrespective of function selected.
- Pre-selectable limit checks (Go / No-Go option) for MW/GW An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
- Lead resistance null facility: The instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances.
- Storage of MIN / MAX values In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored
- Storage Memory for last 10 readings. The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, Continuity and Resistance measurement.
- Blown fuse indication. The display FUSE points to a blown fuse.
- Low battery indication. Automatic display of the Symbol “ ” when battery cells are exhausted.
- Stop Watch. : This function allows you to measure elapsed time up to 1 hour.
- Auto-power off function : The instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation.
- Protective holster for rough duty . A holster of soft rubber with tilt stand protects the meter against damage in the case of shock and drop
-
Rish Insu-20 Analog – Digital Insulation and Continuity Tester
SPECIFICATIONS
- Temperature Coefficient : <0.1% per °C
- Operating Temperature : -20°C To +40°C (full range) -20°C To +60°C (upto 100M )
- Storage Temperature : -25°C To +65°C
- Relative Humidity : 90% RH at 40°C max.
- Display : LCD display Field (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functions
- Dimensions : 84 mm x 195 mm x 35 mm
- Weight : 500 g including battery
FEATURES
- Analog + Digital Display ( Log scale for Insulation Measurement) : The Analog scale for insulation resistance measurement is Logarithmic in nature which gives the dynamic performance of an Analog insulation tester. The Analog scale is linear for low Ohm and Voltage measurement.
- User Selectable Backlit Display: The instrument is provided with user selectable Back lit for taking measurements in dark areas/poor lighting conditions.
- Connector jack for External Mains Adapter (Optional) : The instrument can be operated from Mains Supply(230VAC) instead of Batteries using an external Mains Adapter (230VAC /9VDC,500mA (4.5VA) Isolated)
- Test Voltages 50V/ 100V/ 250V,/500V /1000V : Test voltages from 50V to 1000V can be selected for Insulation Resistance measurement .It covers all insulation tests up to 1000V
- Insulation Resistance measurement: The instrument is capable of measuring insulation resistance from 10 kW…2 GW
- Low Resistances measurement: 0.01 W … 99.9 W Low resistances can be measured up to 99.9 W. There are two measuring ranges for Low W.: 9.99W and 99.9W
- Hands-free continuity testing: Continuity testing (0-10 W with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
- Voltmeter: Instrument measures voltages >25V …600V AC/DC
- Automatic discharge for capacitive circuits after test measurement: Capacitive devices under test, such as cables and windings, that get charged during the test, are discharged by the tester.
- Live circuit detection: Displays presence of voltages 25V irrespective of function selected.
- Pre-selectable limit checks (Go / No-Go option) for MW/GW An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
- Lead resistance null facility: The instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances.
- Storage of MIN / MAX values In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored
- Storage Memory for last 10 readings. The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, Continuity and Resistance measurement.
- Blown fuse indication. The display FUSE points to a blown fuse.
- Low battery indication. Automatic display of the Symbol “ ” when battery cells are exhausted.
- Stop Watch. : This function allows you to measure elapsed time up to 1 hour.
- Auto-power off function : The instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation.
- Protective holster for rough duty . A holster of soft rubber with tilt stand protects the meter against damage in the case of shock and drop
-
Rishabh AIT 501 Smart 5KV Digital Insulation Tester
SPECIFICATIONS
- Test Voltages : 500V, 1000V, 2500V, 5000V
- Test Voltage Accuracy : 0% to 20%
- 500V Range (Accuracy) : 1MOhm to 20GOhm (± 3%+5)
- 1000V Range (Accuracy) : 2MOhm to 40GOhm (± 3%+5)
- 2500V Range (Accuracy) : 5MOhm to 100GOhm (± 3%+5)
- 5000V Range (Accuracy) : 10MOhm to 1000GOhm (± 3%+5)
- Short Circuit Current : 1.8 mA
- AC/ DC Voltage : 600V
- Low Resistance : 0.1Ohm to 999.9Ohm
- Operating Temperature : -10 to 40 °C
- Storage Temperature : -20 to 60° C
- Relative humidity : 85% @ -10 °C to 40 °C
- Dimensions : 202 x 155 x 94 mm
- LCD Size : 123mm x 58mm
- Net Weight: Approx. 2kg (including battery)
FEATURES
- Robust unit
- Test voltages of 500V, 1000V, 2500V and 5000V & Insulation Resistance measurement upto 1 T Ohm
- Automatic Polarisation Index (PI), Dielectric Absorption Ratio (DAR)
- DC/AC voltage measurements to 600V
- Autoranging insulation resistance tester
- Auto shut down when left idle & Optional Operation on Mains via adapter
- Datalogging capabilities and USB interface
- Comparator Function
- Wide LCD with backlit screen, Analog bar graph (30 segment)