A clamp meter is an electrical test tool that combines a basic digital multimeter with a current sensor.
Clamps measure current. Probes measure voltage. Having a hinged jaw integrated into an electrical meter allows technicians to clamp the jaws around a wire, cable or other conductor at any point in an electrical system, then measure current in that circuit without disconnecting/deenergizing it.
Beneath their plastic moldings, hard jaws consist of ferrite iron and are engineered to detect, concentrate and measure the magnetic field being generated by current as it flows through a conductor.
DC Voltage: 600V
Accuracy: ±(1% + 2 digits)
Resolution: 1V Input Resistance: About 10MΩ Max. Input Voltage: 600V DC or 600V RMS AC
AC Voltage: 600V
Accuracy: ±(1.2% + 10 digits)
Resolution: 1V Input Resistance: About 10MΩ Frequency range: 40Hz – 400Hz Max. Input Voltage: 600V DC or 600V RMS AC
AC Current: 600A
Accuracy: ±(2.5% + 10 digits)
Resolution: 0.1A Frequency Range: 50Hz ~ 60Hz Max. Input Current: 120% of full scale, less than 60 seconds
Resistance: 40MΩ
Accuracy: ±(2% + 5 digits)
Resolution: 10kΩ ( Overload Protection: 600V DC or 600V RMS AC )
Capacitance: 40mF
Accuracy: ±(4% + 3 digits )
Resolution: 10uF ( Overload Protection: 600V DC or 600V RMS AC )
Diode test: Forward voltage drop value (open circuit voltage about 2.3V)
Continuity test: Beeper sounds when resistance is less than 50 OHMS (open circuit voltage about 2.1V)
DC Voltage: 600V
Accuracy: ±(0.5% + 3 digits)
Resolution: 0.1V In AUTO mode, input voltage ranges from 0.8V to 600V DC Input voltage range in mV mode: 0.0mV ~ 600 mV DC
AC Voltage(T-RMS): 600V
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1V In AUTO mode, input voltage ranges from 0.8V to 600V AC Input Voltage range in mV mode: 0.0mV to 600mV AC Frequency: 40Hz ~ 1000Hz
AC Current: 600A
Accuracy: ±(1.0% + 8 digits)
Resolution: 0.1A Frequency Range: 40Hz ~ 400Hz – Response: average value Min. Input Current: 0.8A AC Max. Input Current: 600A AC
Resistance: 60MΩ
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1MΩ Open Circuit voltage: approx.. 0.4V Overload Protection: 600V DC or AC (valid value)
Capacitance: 60 mF
Accuracy: ±(2.5% + 20 digits)
Resolution: 0.001 mF Overload Protection: 600V DC or AC Valid value
Frequency: 10Mhz
Accuracy: ±(2.5% + 20 digits)
Resolution: 0.001 Mhz Measuring range: 1Hz ~ 10Mhz Input signal pattern: >0.8V AC current (RMS)
Diode Test: Display approximate for ward voltage of diode
Continuity: Built in Buzzer will be sounded if resistance is less than 50 Ohms
Diode Test: 00.1V Display approximate for ward voltage of Diode.
• Forward DC Current is about 1mA.
• Reverse DC voltage is about 3.3V
• Overload Protection:250V DC or AC (valid value)
Continuity Test: 0.1Ω Built-in buzzer will be sounded if resistance is less than 50Ω
• Overload Protection:250V DC or AC (valid value)
DC Voltage: 600V
Accuracy: ±(0.5% + 3 digits)
Resolution: 0.1V In AUTO mode, input voltage ranges from 0.8V to 600V DC Input voltage range in mV mode: 0.0mV ~ 600 mV DC
AC Voltage: 600V
Accuracy: ±(0.8% + 10 digits)
Resolution: 1V In AUTO mode, input voltage ranges from 0.8V to 600V AC Input Voltage range in mV mode: 0.0mV to 600mV AC Frequency: 40Hz ~ 1000Hz
AC Current: 600A
Accuracy: ±(2.5% + 30 digits)
Resolution: 0.1A Frequency Range: 40Hz ~ 400Hz – Response: average value Min. Input Current: 0.8A AC Max. Input Current: 600A AC
DC Current: 600A
Accuracy: ±(2.5% + 30 digits)
Resolution: 0.1A Frequency Range: 40Hz ~ 400Hz – Response: average value Min. Input Current: 0.8A AC Max. Input Current: 600A DC
Resistance: 60MΩ
Accuracy: ±(0.8% + 3 digits)
Resolution: 0.1mΩ ( Overload Protection: 600V DC or 600V AC )
Capacitance: 60mF
Accuracy: ±(2.5% + 20 digits )
Resolution: 0.01MF ( Overload Protection: 600V DC or 600V AC )
Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
The large backlight display facilitates readings in dark environments
Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
Current frequency measurement
Precision down to 0.01A and 0.1V
1000A/600A AC/DC current measurement (319/317)
600V AC/DC voltage measurement
4000Ω resistance measurement
Continuity beeper
Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
The large backlight display facilitates readings in dark environments
Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
Current frequency measurement
Precision down to 0.01A and 0.1V
1000A/600A AC/DC current measurement (319/317)
600V AC/DC voltage measurement
4000Ω resistance measurement
Continuity beeper
Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen