Showing 65–80 of 94 results

  • HTC IRX-67 Digital Infrared Thermometer -50° to 1200°C

    SPECIFICATIONS

    • Range : -50~1380˚C / -58~2516˚F
    • Response Time : < 250 ms
    • Resolution : 0.1˚C upto 1000˚C Above 1˚C
    • Basic Accuracy(IR) : ± 1.5% of reading
    • Optical Resolution (Distance Spot) : 50 : 1
    • Emissivity : Adjustable 0.10~1.0
    • Type K Temp. Range : -50~1370˚C/-58~2498˚F
    • Basic Accuracy (TK) : ±1.5% of reading
    • Reading memories : 99

    FEATURES

    • User Selectable ˚C or ˚F
    • Circular Laser Targeting
    • Automatic Data Hold
    • Over Range Indication
    • Trigger Lock
    • Type K Input
    • USB Interface
    • Colour LCD Display with Backlight
    • Auto Power Off (APO)
    • POWER : 9V (6F22) X 1
    • Standard Accessories : USB Cable & software, Tripod, TP-01 Temperature Probe, Hard Carrying Case, Manual
    • Dimension : 192(H) x 120(W) x 59(D)mm
    Read more
  • HTC IRX-68 Infrared Optical Thermometer -50°C – 1850°C

    SPECIFICATIONS

    • Range : -50~1980˚C / -58~3596˚F
    • Response Time : < 250 ms
    • Resolution : 0.1˚C upto 1000˚C Above 1˚C
    • Basic Accuracy(IR) : ± 1.5% of reading
    • Optical Resolution (Distance Spot) : 50 : 1
    • Emissivity : Adjustable 0.10~1.0
    • Type K Temp. Range : -50~1370˚C/-58~2498˚F
    • Basic Accuracy (TK) : ±1.5% of reading
    • Reading memories : 99

    FEATURES

    • User Selectable ˚C or ˚F
    • Circular Laser Targeting
    • Automatic Data Hold
    • Over Range Indication
    • Trigger Lock
    • Type K Input
    • USB Interface
    • Colour LCD Display with Backlight
    • Auto Power Off (APO)
    • POWER : 9V (6F22) X 1
    • Standard Accessories : USB Cable & software, Tripod, TP-01 Temperature Probe, Hard Carrying Case, Manual
    • Dimension : 192(H) x 120(W) x 59(D)mm
    Read more
  • HTC IRX-69 Infrared Optical Thermometer -50°C – 2200°C

    SPECIFICATIONS

    • Range : -50~2280˚C / -58~4136˚F
    • Response Time : < 250 ms
    • Resolution : 0.1˚C upto 1000˚C Above 1˚C
    • Basic Accuracy(IR) : ± 1.5% of reading
    • Optical Resolution (Distance Spot) : 50 : 1
    • Emissivity : Adjustable 0.10~1.0
    • Type K Temp. Range : -50~1370˚C/-58~2498˚F
    • Basic Accuracy (TK) : ±1.5% of reading
    • Reading memories : 99

    FEATURES

    • User Selectable ˚C or ˚F
    • Circular Laser Targeting
    • Automatic Data Hold
    • Over Range Indication
    • Trigger Lock
    • Type K Input
    • USB Interface
    • Colour LCD Display with Backlight
    • Auto Power Off (APO)
    • POWER : 9V (6F22) X 1
    • Standard Accessories : USB Cable & software, Tripod, TP-01 Temperature Probe, Hard Carrying Case, Manual
    • Dimension : 192(H) x 120(W) x 59(D)mm
    Read more
  • HTC LCR-4070 Digital LCR Meter

    SPECIFICATIONS

    CAPACITANCE

    • RANGE : 200pF
    • RESOLUTION : 0.1pF
    • ACCURACY : ±2.5% of rdg + 5 digits

    RESISTANCE

    • RANGE : 20Ω
    • RESOLUTION : 0.01Ω
    • ACCURACY : ±1.0% of rdg + 5 digits

    INDUCTANCE

    • RANGE : 200µH
    • RESOLUTION  : 0.1µH
    • ACCURACY : ±3.0% of rdg + 5 digits

    FEATURES

    • 3½ Digit Display
    • 1,999 Count
    • Full Protection function, capacitor with the function of Self discharge
    • Auto Power Off (APO

    SPECIAL FUNCTIONS

    • Low Battery Indication Approx. <7.5V
    • Sampling Rate 3 times per second
    • Capacitance discharge protection ✔
    • Power 9V (6F22) x 1
    • Standard Accessories : Soft Carrying Case, Test Lead, Manual
    • Dimension : 185(H) x 93(W) x 35(D)mm
    Read more
  • HTC LCR-4080Q LCD Display LCR-Q Meter

    SPECIFICATIONS

    • Resistance Accuracy : ±(1.0%+5)
    • Counts : 19999
    • Inductance Gear Display Range : 20mH-2000H
    • Capacitance Range : 20nF-20mF
    • Frequency Range (Hz) : 100Hz/120Hz/1KHz/10KHz/100KHz
    • Inductance Gear Accuracy : ±(2%+5)
    • Resistance Min. : 0.01kΩ-1kΩ
    • Resistance Range : 200Ω-20MΩ
    • Inductance Gear Min. Resolution : 1pF-0.1mF

    FEATURES

    • LCR automatic identification/manual measurement
    • Open/short calibration
    • Power : 9V (6F22) X 1
    Read more
  • HTC LX-101A Digital Lux Meter

    SPECIFICATIONS

    • RANGE : 0~2,00,000 LUX
    • RESOLUTION : 0.1 LUX
    • ACCURACY : +5% of reading ± 10% FS
    • RECEIVING LIGHT : Silicon Photo Electricity Diode
    • POWER : 9V (6F22) x 1

    FEATURES

    • Data Hold
    • Auto Power Off (APO)
    • Standard Accessories: Soft Carrying Case, Manual
    • Dimension: Photo Detector: 100(H) x 60(W) x 27(D)mm
      130(H) x 95(W) x 30(D)mm
    Read more
  • HTC LX-102A Digital Lux Meter

    SPECIFICATIONS

    • RANGE : 0~2,00,000 LUX
    • RESOLUTION : 0~20,000 FC
    • ACCURACY : +5% of reading ± 10% FS
    • RECEIVING LIGHT : Silicon Photo Electricity Diode
    • POWER : 9V (6F22) x 1

    FEATURES

    • Data Hold
    • Auto Power Off (APO)
    • Standard Accessories: Soft Carrying Case, Manual
    • Dimension: Photo Detector: 100(H) x 60(W) x 27(D)mm
      130(H) x 95(W) x 30(D)mm
    Read more
  • HTC LX-103 Lux Meter

    SPECIFICATIONS

    • RANGE : 0~1,00,000 LUX / 0~10,000 FC
    • RESOLUTION : 1 LUX/1 FC
    • ACCURACY : ± (3%+5 LUX)
    • RECEIVING LIGHT : Silicon Photo Diode & Spectral Response Filter
    • POWER : AAA 1.5V X 3

    FEATURES

    • Large Range upto 1,00,000 LUX
    • Large LCD Display with Backlight & Bar Graph
    • Auto Power Off (APO)
    • Data Hold & Max/Min
    • Standard Accessories: Soft Carrying Case, Manual
    • Dimension: 184(H) x 60(W) x 29(D)mm
    Read more
  • HTC LX-104 Digital Lux Meter

    SPECIFICATIONS

    • RANGE : 4,00,000 LUX
    • RESOLUTION : 0.1 LUX/0.01 FC
    • ACCURACY : ±5% of reading ± 10 Digits (<10,000 LUX) ; ±10% of reading ± 10 Digits (<10,000 LUX)
    • RECEIVING LIGHT : Silicon Photo Electricity Diode
    • POWER : 9V (6F22) x 1

    FEATURES

    • 3,999 Count with Bar Graph 61 Segments
    • User selectable FC/LUX
    • USB Computer Interface (Advance Software Program for all windows)
    • Capacity of Data Logging 99
    • Standard Accessories: Soft Carrying Case, Manual, Photo Detector and USB Cable & Software.
    • Dimension: Photo Detector: 115(H) x 60(W) x 27(D)mm
      203(H) x 75(W) x 50(D)mm
    Read more
  • HTC LX-107 Digital Multimeter

    SPECIFICATIONS

    • RANGE : 2000 W/m2 LUX; 634BTU (ft2 x h) FC
    • RESOLUTION : 1W/m2 /1BTU FC
    • ACCURACY : ±10 W/m2 or ± 5% ; ± BTU/(ft2 x h) or ± 5%
    • POWER : 9V (6F22) x 1

    FEATURES

    • 3 ½ Digits (1999 Digits)
    • Select either Watts per Square Meter (W/m2) or BTU
    • Max/Min. Peak Hold functions
    • Data Hold
    • Compass Functions, Easy to know the direction.
    • Standard Accessories: Soft Carrying Case, Manual
    • Dimension: 130(H) x 95(W) x 30(D)mm
    Read more
  • HTC Mini Anemometer, AVM-03

    SPECIFICATIONS

    WIND SPEED

    • RANGE : 0.70~30.00 m/s
    • RESOLUTION : 0.01
    • ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
    • RANGE : 2.50~108.0 km/h
    • RESOLUTION : 0.01
    • ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
    • RANGE : 2.30~98.50 ft/s
    • RESOLUTION : 0.01
    • ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
    • RANGE : 137.0~5900 ft/m
    • RESOLUTION : 0.1
    • ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
    • RANGE : 1.30~58.30 Knots
    • RESOLUTION : 0.01
    • ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)\
    • RANGE : 1.30~58.30 Knots
    • RESOLUTION : 0.01
    • ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
    • RANGE : 1.50~67.10 mil/h
    • RESOLUTION : 0.01
    • ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)

    TEMPERATURE

    • ºC
    • RANGE : -20.0~60.0ºC
    • RESOLUTION : 0.1ºC
    • ACCURACY : 0.0 C ~ 45.0 C 1.0 C others ± 1.5 C
    • ºF
    • RANGE : -4.0~140.0ºF
    • RESOLUTION : 0.1ºF
    • ACCURACY : 32ºF ~ 113ºF ±2.0ºF others ± 3.0ºF

    HUMIDITY

    • RANGE : 0.0% ~ 99.9 % RH
    • RESOLUTION : 0.1%RH
    • ACCURACY : 20%~80% ±5.0% RH others ± 6.0% RH

    FEATURES

    • Data Hold
    • Max/Min
    • Back Light
    • Temp and Humidity
    • Auto Power Off (APO 10 Min)
    • Power : AAA 1.5 V X 3
    • Standard Accesories : Manual, Soft Carry Case
    • Dimension : 138 (H)X 56(W) X 25(D) mm
    Read more
  • HTC MO-5000 Digital Miliohm Meter

    SPECIFICATIONS

    • RANGE : 20mΩ ; 200 mΩ
    • RESOLUTION : 0.01mΩ ; 0.1mΩ
    • ACCURACY : ±0.5% of rdg ± 3 digits
    • MEASURING CURRENT : 100mA ; 50mA
    Read more
  • HTC MT-6 Infrared Optical Thermometer -20°C – 750°C

    SPECIFICATIONS

    • Temperature Range : -50~750˚C / -4~1382˚F
    • Accuracy : ±2.0% of rdg+2˚C digits
    • Distance Spot Ratio : 12:1
    • Emmissivity : Adjustable 0.1~1.0
    • Spectral Response : 8~14um
    • Resolution : 0.1˚C / 0.1˚F

    FEATURES

    • ˚C or ˚F Selection Circular
    • Circular Laser
    • Auto Power Off (APO)
    • Data Hold Function
    • Colour LCD Display
    • POWER : 9V (6F22) X 1
    • Standard Accessories : Soft Carrying Case, Manual
    • Dimension : 132(H) x 55(W) x 168(D)mm
    Read more
  • HTC MT-8 INFRARED THERMOMETER 800˚C

    SPECIFICATIONS

    • Temperature Range : -50~800˚C/-58~1472˚F
    • Accuracy : ±1.5%
    • Distance Spot Ratio : 12:1
    • Emmissivity : Adjustable 0.10 ~1.00
    • Spectral Response : 8~14um
    • Resolution : 0.1˚C / 0.1˚F
    • Relative Humidity : 0~99%RH

    FEATURES

    • ˚C or ˚F Selection
    • Colour LCD
    • Auto Power Off (APO)
    • Circular Laser
    • Data Hold Function
    • POWER : AAA 1.5V X 2
    • Standard Accessories : Manual
    • Dimension : 148(H) x 102(W) x 46(D)mm
    Read more
  • HTC MT4 Digital Infrared Thermometer Temp Range -20° to 530°C

    SPECIFICATIONS

    • Temperature Range : -50˚ to 550˚C / -58˚F to 1022˚F
    • Accuracy : -20˚C to 0˚C/-4˚F to 32:4˚C/7˚F Above 0˚C/32˚F:±2% of reading ±2˚C/3.6˚F
    • Distance Spot Ratio : 12:1
    • Emmissivity : Adjustable 0.1~1.0
    • Spectral Response : 8~14um
    • Resolution : 0.1˚C / 0.1˚F

    FEATURES

    • ˚C or ˚F Selection Circular
    • Circular Laser
    • Auto Power Off (APO)
    • Data Hold Function
    • Colour LCD Display
    • POWER : 9V (6F22) X 1
    • Standard Accessories : Soft Carrying Case, Manual
    • Dimension : 132(H) x 55(W) x 168(D)mm
    Read more
  • HTC MTX-1 Infrared Thermometer -50°C – 550°C

    SPECIFICATIONS

    • Temperature Range : -50 ~ 550˚C/58~1022˚F
    • Accuracy : -30˚C-0˚C(-22˚F-32˚F), ±3˚C ; 0˚C-55˚C(-22˚F-1022˚F), ±(1.5%+2˚C)
    • Distance Spot Ratio : 12:1
    • Emmissivity : Adjustable 0.1~1.0
    • Resolution : 0.1˚C / 0.1˚F

    FEATURES

    • ˚C or ˚F Selection
    • Circular Laser
    • Auto Power Off (APO)
    • Colour LED Display
    • High Alarm Indicators
    • POWER : AAA 1.5V x 2
    • Standard Accessories : Manual
    • Dimension : 43(H) x 155(W) x 160(D)mm
    Read more