HTC IRX-67 Digital Infrared Thermometer -50° to 1200°C
SPECIFICATIONS
- Range : -50~1380˚C / -58~2516˚F
- Response Time : < 250 ms
- Resolution : 0.1˚C upto 1000˚C Above 1˚C
- Basic Accuracy(IR) : ± 1.5% of reading
- Optical Resolution (Distance Spot) : 50 : 1
- Emissivity : Adjustable 0.10~1.0
- Type K Temp. Range : -50~1370˚C/-58~2498˚F
- Basic Accuracy (TK) : ±1.5% of reading
- Reading memories : 99
FEATURES
- User Selectable ˚C or ˚F
- Circular Laser Targeting
- Automatic Data Hold
- Over Range Indication
- Trigger Lock
- Type K Input
- USB Interface
- Colour LCD Display with Backlight
- Auto Power Off (APO)
- POWER : 9V (6F22) X 1
- Standard Accessories : USB Cable & software, Tripod, TP-01 Temperature Probe, Hard Carrying Case, Manual
- Dimension : 192(H) x 120(W) x 59(D)mm
-
HTC IRX-68 Infrared Optical Thermometer -50°C – 1850°C
SPECIFICATIONS
- Range : -50~1980˚C / -58~3596˚F
- Response Time : < 250 ms
- Resolution : 0.1˚C upto 1000˚C Above 1˚C
- Basic Accuracy(IR) : ± 1.5% of reading
- Optical Resolution (Distance Spot) : 50 : 1
- Emissivity : Adjustable 0.10~1.0
- Type K Temp. Range : -50~1370˚C/-58~2498˚F
- Basic Accuracy (TK) : ±1.5% of reading
- Reading memories : 99
FEATURES
- User Selectable ˚C or ˚F
- Circular Laser Targeting
- Automatic Data Hold
- Over Range Indication
- Trigger Lock
- Type K Input
- USB Interface
- Colour LCD Display with Backlight
- Auto Power Off (APO)
- POWER : 9V (6F22) X 1
- Standard Accessories : USB Cable & software, Tripod, TP-01 Temperature Probe, Hard Carrying Case, Manual
- Dimension : 192(H) x 120(W) x 59(D)mm
-
HTC IRX-69 Infrared Optical Thermometer -50°C – 2200°C
SPECIFICATIONS
- Range : -50~2280˚C / -58~4136˚F
- Response Time : < 250 ms
- Resolution : 0.1˚C upto 1000˚C Above 1˚C
- Basic Accuracy(IR) : ± 1.5% of reading
- Optical Resolution (Distance Spot) : 50 : 1
- Emissivity : Adjustable 0.10~1.0
- Type K Temp. Range : -50~1370˚C/-58~2498˚F
- Basic Accuracy (TK) : ±1.5% of reading
- Reading memories : 99
FEATURES
- User Selectable ˚C or ˚F
- Circular Laser Targeting
- Automatic Data Hold
- Over Range Indication
- Trigger Lock
- Type K Input
- USB Interface
- Colour LCD Display with Backlight
- Auto Power Off (APO)
- POWER : 9V (6F22) X 1
- Standard Accessories : USB Cable & software, Tripod, TP-01 Temperature Probe, Hard Carrying Case, Manual
- Dimension : 192(H) x 120(W) x 59(D)mm
-
HTC LCR-4070 Digital LCR Meter
SPECIFICATIONS
CAPACITANCE
- RANGE : 200pF
- RESOLUTION : 0.1pF
- ACCURACY : ±2.5% of rdg + 5 digits
RESISTANCE
- RANGE : 20Ω
- RESOLUTION : 0.01Ω
- ACCURACY : ±1.0% of rdg + 5 digits
INDUCTANCE
- RANGE : 200µH
- RESOLUTION : 0.1µH
- ACCURACY : ±3.0% of rdg + 5 digits
FEATURES
- 3½ Digit Display
- 1,999 Count
- Full Protection function, capacitor with the function of Self discharge
- Auto Power Off (APO
SPECIAL FUNCTIONS
- Low Battery Indication Approx. <7.5V
- Sampling Rate 3 times per second
- Capacitance discharge protection ✔
- Power 9V (6F22) x 1
- Standard Accessories : Soft Carrying Case, Test Lead, Manual
- Dimension : 185(H) x 93(W) x 35(D)mm
-
HTC LCR-4080Q LCD Display LCR-Q Meter
SPECIFICATIONS
- Resistance Accuracy : ±(1.0%+5)
- Counts : 19999
- Inductance Gear Display Range : 20mH-2000H
- Capacitance Range : 20nF-20mF
- Frequency Range (Hz) : 100Hz/120Hz/1KHz/10KHz/100KHz
- Inductance Gear Accuracy : ±(2%+5)
- Resistance Min. : 0.01kΩ-1kΩ
- Resistance Range : 200Ω-20MΩ
- Inductance Gear Min. Resolution : 1pF-0.1mF
FEATURES
- LCR automatic identification/manual measurement
- Open/short calibration
- Power : 9V (6F22) X 1
-
HTC LX-101A Digital Lux Meter
SPECIFICATIONS
- RANGE : 0~2,00,000 LUX
- RESOLUTION : 0.1 LUX
- ACCURACY : +5% of reading ± 10% FS
- RECEIVING LIGHT : Silicon Photo Electricity Diode
- POWER : 9V (6F22) x 1
FEATURES
- Data Hold
- Auto Power Off (APO)
- Standard Accessories: Soft Carrying Case, Manual
- Dimension: Photo Detector: 100(H) x 60(W) x 27(D)mm
130(H) x 95(W) x 30(D)mm
-
HTC LX-102A Digital Lux Meter
SPECIFICATIONS
- RANGE : 0~2,00,000 LUX
- RESOLUTION : 0~20,000 FC
- ACCURACY : +5% of reading ± 10% FS
- RECEIVING LIGHT : Silicon Photo Electricity Diode
- POWER : 9V (6F22) x 1
FEATURES
- Data Hold
- Auto Power Off (APO)
- Standard Accessories: Soft Carrying Case, Manual
- Dimension: Photo Detector: 100(H) x 60(W) x 27(D)mm
130(H) x 95(W) x 30(D)mm
-
HTC LX-103 Lux Meter
SPECIFICATIONS
- RANGE : 0~1,00,000 LUX / 0~10,000 FC
- RESOLUTION : 1 LUX/1 FC
- ACCURACY : ± (3%+5 LUX)
- RECEIVING LIGHT : Silicon Photo Diode & Spectral Response Filter
- POWER : AAA 1.5V X 3
FEATURES
- Large Range upto 1,00,000 LUX
- Large LCD Display with Backlight & Bar Graph
- Auto Power Off (APO)
- Data Hold & Max/Min
- Standard Accessories: Soft Carrying Case, Manual
- Dimension: 184(H) x 60(W) x 29(D)mm
-
HTC LX-104 Digital Lux Meter
SPECIFICATIONS
- RANGE : 4,00,000 LUX
- RESOLUTION : 0.1 LUX/0.01 FC
- ACCURACY : ±5% of reading ± 10 Digits (<10,000 LUX) ; ±10% of reading ± 10 Digits (<10,000 LUX)
- RECEIVING LIGHT : Silicon Photo Electricity Diode
- POWER : 9V (6F22) x 1
FEATURES
- 3,999 Count with Bar Graph 61 Segments
- User selectable FC/LUX
- USB Computer Interface (Advance Software Program for all windows)
- Capacity of Data Logging 99
- Standard Accessories: Soft Carrying Case, Manual, Photo Detector and USB Cable & Software.
- Dimension: Photo Detector: 115(H) x 60(W) x 27(D)mm
203(H) x 75(W) x 50(D)mm
-
HTC LX-107 Digital Multimeter
SPECIFICATIONS
- RANGE : 2000 W/m2 LUX; 634BTU (ft2 x h) FC
- RESOLUTION : 1W/m2 /1BTU FC
- ACCURACY : ±10 W/m2 or ± 5% ; ± BTU/(ft2 x h) or ± 5%
- POWER : 9V (6F22) x 1
FEATURES
- 3 ½ Digits (1999 Digits)
- Select either Watts per Square Meter (W/m2) or BTU
- Max/Min. Peak Hold functions
- Data Hold
- Compass Functions, Easy to know the direction.
- Standard Accessories: Soft Carrying Case, Manual
- Dimension: 130(H) x 95(W) x 30(D)mm
-
HTC Mini Anemometer, AVM-03
SPECIFICATIONS
WIND SPEED
- RANGE : 0.70~30.00 m/s
- RESOLUTION : 0.01
- ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
- RANGE : 2.50~108.0 km/h
- RESOLUTION : 0.01
- ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
- RANGE : 2.30~98.50 ft/s
- RESOLUTION : 0.01
- ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
- RANGE : 137.0~5900 ft/m
- RESOLUTION : 0.1
- ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
- RANGE : 1.30~58.30 Knots
- RESOLUTION : 0.01
- ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)\
- RANGE : 1.30~58.30 Knots
- RESOLUTION : 0.01
- ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
- RANGE : 1.50~67.10 mil/h
- RESOLUTION : 0.01
- ACCURACY : < 1.00 m/s ±0.7 m/s ; 1.00~30.00 m/s ± (2% +0.5 m/s)
TEMPERATURE
- ºC
- RANGE : -20.0~60.0ºC
- RESOLUTION : 0.1ºC
- ACCURACY : 0.0 C ~ 45.0 C 1.0 C others ± 1.5 C
- ºF
- RANGE : -4.0~140.0ºF
- RESOLUTION : 0.1ºF
- ACCURACY : 32ºF ~ 113ºF ±2.0ºF others ± 3.0ºF
HUMIDITY
- RANGE : 0.0% ~ 99.9 % RH
- RESOLUTION : 0.1%RH
- ACCURACY : 20%~80% ±5.0% RH others ± 6.0% RH
FEATURES
- Data Hold
- Max/Min
- Back Light
- Temp and Humidity
- Auto Power Off (APO 10 Min)
- Power : AAA 1.5 V X 3
- Standard Accesories : Manual, Soft Carry Case
- Dimension : 138 (H)X 56(W) X 25(D) mm
-
HTC MO-5000 Digital Miliohm Meter
SPECIFICATIONS
- RANGE : 20mΩ ; 200 mΩ
- RESOLUTION : 0.01mΩ ; 0.1mΩ
- ACCURACY : ±0.5% of rdg ± 3 digits
- MEASURING CURRENT : 100mA ; 50mA
-
HTC MT-6 Infrared Optical Thermometer -20°C – 750°C
SPECIFICATIONS
- Temperature Range : -50~750˚C / -4~1382˚F
- Accuracy : ±2.0% of rdg+2˚C digits
- Distance Spot Ratio : 12:1
- Emmissivity : Adjustable 0.1~1.0
- Spectral Response : 8~14um
- Resolution : 0.1˚C / 0.1˚F
FEATURES
- ˚C or ˚F Selection Circular
- Circular Laser
- Auto Power Off (APO)
- Data Hold Function
- Colour LCD Display
- POWER : 9V (6F22) X 1
- Standard Accessories : Soft Carrying Case, Manual
- Dimension : 132(H) x 55(W) x 168(D)mm
-
HTC MT-8 INFRARED THERMOMETER 800˚C
SPECIFICATIONS
- Temperature Range : -50~800˚C/-58~1472˚F
- Accuracy : ±1.5%
- Distance Spot Ratio : 12:1
- Emmissivity : Adjustable 0.10 ~1.00
- Spectral Response : 8~14um
- Resolution : 0.1˚C / 0.1˚F
- Relative Humidity : 0~99%RH
FEATURES
- ˚C or ˚F Selection
- Colour LCD
- Auto Power Off (APO)
- Circular Laser
- Data Hold Function
- POWER : AAA 1.5V X 2
- Standard Accessories : Manual
- Dimension : 148(H) x 102(W) x 46(D)mm
-
HTC MT4 Digital Infrared Thermometer Temp Range -20° to 530°C
SPECIFICATIONS
- Temperature Range : -50˚ to 550˚C / -58˚F to 1022˚F
- Accuracy : -20˚C to 0˚C/-4˚F to 32:4˚C/7˚F Above 0˚C/32˚F:±2% of reading ±2˚C/3.6˚F
- Distance Spot Ratio : 12:1
- Emmissivity : Adjustable 0.1~1.0
- Spectral Response : 8~14um
- Resolution : 0.1˚C / 0.1˚F
FEATURES
- ˚C or ˚F Selection Circular
- Circular Laser
- Auto Power Off (APO)
- Data Hold Function
- Colour LCD Display
- POWER : 9V (6F22) X 1
- Standard Accessories : Soft Carrying Case, Manual
- Dimension : 132(H) x 55(W) x 168(D)mm
-
HTC MTX-1 Infrared Thermometer -50°C – 550°C
SPECIFICATIONS
- Temperature Range : -50 ~ 550˚C/58~1022˚F
- Accuracy : -30˚C-0˚C(-22˚F-32˚F), ±3˚C ; 0˚C-55˚C(-22˚F-1022˚F), ±(1.5%+2˚C)
- Distance Spot Ratio : 12:1
- Emmissivity : Adjustable 0.1~1.0
- Resolution : 0.1˚C / 0.1˚F
FEATURES
- ˚C or ˚F Selection
- Circular Laser
- Auto Power Off (APO)
- Colour LED Display
- High Alarm Indicators
- POWER : AAA 1.5V x 2
- Standard Accessories : Manual
- Dimension : 43(H) x 155(W) x 160(D)mm