MECO-G R-DIT945K-1 DIGITAL INSULATION TESTER 100/250/500/1000/2500/5000V

Brands:

Availability: In Stock

SPECIFICATIONS

  • Test Voltage : 100V/250V/500V ±10%
    Range : 0.1~20MΩ
    Accuracy : ±(3% + 5dgts)
    Resolution : 0.01MΩ
  • Test Voltage : 1000V/2500V/5000VDC ±10%
    Range : 200MΩ~10GΩ
    Accuracy : ±(5% + 10dgts)
    Resolution : 0.01MΩ
  • Display : 3½ Dgt. (1999 Counts) Large LCD Display with 29mm Display Height.
  • Accuracy : ±(3% + 5dgts)
  • Operating Temperature : 0°C to 40°C (RH £ 85%)
  • Storage Temperature : -10°C to 50°C (RH £ 75%)
  • Dimensions : 190 x 155 x 75 mm
  • Weight : Approx 900g
  • Power : 12V (8 x 1.5V) (R6AA size batteries) or AC Adaptor 12VDC

FEATURES

  • 3½ Digit (1999 Counts) Large Display with Back light
  • LED Indicator for HV (High Voltage)
  • High Accuracy ±(3% + 2dgts) for Insulation Measurement.
  • In-build Protection Circuit to prevent the damage reverse voltages .
  • LCD Back Light Function with Indicator Switch.
  • Battery Operated / AC adapter
  • 6 Ranges of Insulation Measurement.
  • Display with Annunciators
  • Suitable for calculation PI and DAR (manually)
  • Auto-Ranging (Insulation Measurement)
  • As per IS10656-1983
  • As per EMC standard IEC 61326-1 Class B
  • Over Voltage CAT III, 600V
  • AS per Safety Standard IEC/EN 61010-1 & 61010-31
  • IP-44 Protection

Description

“MECO-G” has introduced a new & advanced multi-range 3½ Dgt. (1999 Counts) Digital Insulation Tester Model: R-DIT945K-1. It has 6 Voltage Ranges i.e. 100V/250V/500V/1000V/2500V/5000V. R-DIT945K-1 has three Ohms (W) ranges, 0-200MW, 200MW-10GW and 10GW-2000GW.

Reviews

There are no reviews yet.

Be the first to review “MECO-G R-DIT945K-1 DIGITAL INSULATION TESTER 100/250/500/1000/2500/5000V”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMECO-G R-DIT945K-1 DIGITAL INSULATION TESTER 100/250/500/1000/2500/5000V removeMECO DIT99BL-A DIGITAL INSULATION TESTER removeRishabh AIT 501 Smart 5KV Digital Insulation Tester removeMECO DIT 99BL-D DIGITAL INSULATION TESTER removeHTC 8252 INSULATION TESTER 15 KV removeMECO DIT 99BL-B DIGITAL INSULATIONS TESTER remove
NameMECO-G R-DIT945K-1 DIGITAL INSULATION TESTER 100/250/500/1000/2500/5000V removeMECO DIT99BL-A DIGITAL INSULATION TESTER removeRishabh AIT 501 Smart 5KV Digital Insulation Tester removeMECO DIT 99BL-D DIGITAL INSULATION TESTER removeHTC 8252 INSULATION TESTER 15 KV removeMECO DIT 99BL-B DIGITAL INSULATIONS TESTER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS
  • Test Voltage : 100V/250V/500V ±10% Range : 0.1~20MΩ Accuracy : ±(3% + 5dgts) Resolution : 0.01MΩ
  • Test Voltage : 1000V/2500V/5000VDC ±10% Range : 200MΩ~10GΩ Accuracy : ±(5% + 10dgts) Resolution : 0.01MΩ
  • Display : 3½ Dgt. (1999 Counts) Large LCD Display with 29mm Display Height.
  • Accuracy : ±(3% + 5dgts)
  • Operating Temperature : 0°C to 40°C (RH £ 85%)
  • Storage Temperature : -10°C to 50°C (RH £ 75%)
  • Dimensions : 190 x 155 x 75 mm
  • Weight : Approx 900g
  • Power : 12V (8 x 1.5V) (R6AA size batteries) or AC Adaptor 12VDC
FEATURES
  • 3½ Digit (1999 Counts) Large Display with Back light
  • LED Indicator for HV (High Voltage)
  • High Accuracy ±(3% + 2dgts) for Insulation Measurement.
  • In-build Protection Circuit to prevent the damage reverse voltages .
  • LCD Back Light Function with Indicator Switch.
  • Battery Operated / AC adapter
  • 6 Ranges of Insulation Measurement.
  • Display with Annunciators
  • Suitable for calculation PI and DAR (manually)
  • Auto-Ranging (Insulation Measurement)
  • As per IS10656-1983
  • As per EMC standard IEC 61326-1 Class B
  • Over Voltage CAT III, 600V
  • AS per Safety Standard IEC/EN 61010-1 & 61010-31
  • IP-44 Protection
SPECIFICATIONS
  • Test Voltages : 500V, 1000V, 2500V, 5000V
  • Test Voltage Accuracy : 0% to 20%
  • 500V Range (Accuracy) : 1MOhm to 20GOhm (± 3%+5)
  • 1000V Range (Accuracy) : 2MOhm to 40GOhm (± 3%+5)
  • 2500V Range (Accuracy) : 5MOhm to 100GOhm (± 3%+5)
  • 5000V Range (Accuracy) : 10MOhm to 1000GOhm (± 3%+5)
  • Short Circuit Current : 1.8 mA
  • AC/ DC Voltage : 600V
  • Low Resistance : 0.1Ohm to 999.9Ohm
  • Operating Temperature : -10 to 40 °C
  • Storage Temperature : -20 to 60° C
  • Relative humidity : 85% @ -10 °C to 40 °C
  • Dimensions  : 202 x 155 x 94 mm
  • LCD Size  : 123mm x 58mm
  • Net Weight: Approx. 2kg (including battery)
FEATURES
  • Robust unit
  • Test voltages of 500V, 1000V, 2500V and 5000V & Insulation Resistance measurement upto 1 T Ohm
  • Automatic Polarisation Index (PI), Dielectric Absorption Ratio (DAR)
  • DC/AC voltage measurements to 600V
  • Autoranging insulation resistance tester
  • Auto shut down when left idle & Optional Operation on Mains via adapter
  • Datalogging capabilities and USB interface
  • Comparator Function
  • Wide LCD with backlit screen, Analog bar graph (30 segment)
SPECIFICATIONS : 
  • INSULATION TEST VOLTAGE : 1000V DC
  • OPERATING TEMPERATURE : 0°C to 50°C
  • INSULATION RESISTANCE TEST RANGE : 0-200 MΩ
  • INSULATION RESISTANCE ACCURACY : ±(3%rdg+2dgt)
FEATURES : 
  • 3½ Digit 17mm LCD Display
  • Terminal Voltage more than 85% of rated Voltage for Insulation Resistance Measurement from 10% to 100% of the Insulation Resistance Range
SPECIFICATIONS
  • Function : Insulation resistance test, voltage test, current test, capacitance test
  • Rated Voltage : 500V; 1000V 2500V; 5000V; 10 KV; 15KV Accuracy Rated Voltage : (1±10%)
  • Resistance Limit Range : 0.01MΩ -50TΩ Accuracy : ±3%rdg±5dgt Resolution : 0.01MΩ
  • Output Short Circuit Current : ≥6mA
  • DC Voltage Range : 0.1~1000V Accuracy : ±1.5%rdg±5dgt Resolution : 0.1V
  • AC Voltage Range : 0.1~750V Accuracy : ±1.5%rdg±5dgt Resolution : 0.1V
  • DC current measurement : 0.01nA~6mA Accuracy : ±5%rdg±5dgt Resolution : 0.01nA
  • Capacitance Test : 10nF~60uF Accuracy Test : ±10%rdg±5dgt Resolution : 10nF
  • Absorption ratio and polarization index measurement power : Have
  • Weight : 2720g (including battery)
  • Power Consumption : Standby: 30mA Max (backlight off) | Turn on backlight: 42mA Max | Measure:200mA Max(backlight off)
  • Insulation Resistance : ≥50MΩ(between Measuring line and housing
  • Pressure Resistance : AC3kV/50Hz 1min
  • Working Temperature & Humidity : -10%ºC+50ºC<85%RH
  • Operating Temperature & Humidity : -10%ºC+55ºC<90%RH
FEATURES
    • Polarization Index (PI)
    • Dielectric Absorption (DAR)
    • Auto Power Off (APO 15 Minutes)
    • USB Interface
    • High Voltage Indication
    • Meter 1PC
    • High voltage bar 1PC Red
    • High voltage test line 2PCS (Black, Green each 1)
    • Monitoring Software CD 1PC
    • USB communication line USB 1PC
    • Charger 1PC
    • Manual, certificate 1 Set
    • Instrument Box 1PC
     
SPECIFICATIONS : 
  • DC VOLTAGE : 250 V
  • RANGES : 0 - 200 M Ohms
  • RESOLUTION : 0.1 M Ohms
FEATURES :
  • Testing insulation is essential to keeping wires and motors working properly.
  • The analog insulation tester will measure the resistance in ohms and will display the results on a dial.
  • It can also be used on the wire insulation, as well as cables and cords.
  • The analog insulation tester is made up of a set of probes that are inserted into the insulation to test the insulation resistance.
Content“MECO-G” has introduced a new & advanced multi-range 3½ Dgt. (1999 Counts) Digital Insulation Tester Model: R-DIT945K-1. It has 6 Voltage Ranges i.e. 100V/250V/500V/1000V/2500V/5000V. R-DIT945K-1 has three Ohms (W) ranges, 0-200MW, 200MW-10GW and 10GW-2000GW.MECO DIT-99A Digital Insulation Tester has the following features: 3 Digit 17mm LCD Display; High Accuracy (3% rdg + 2 dgt); Single Person Push Button Operation; Designed to Generally Conform to IS 10656-1983; Meets Requirement of IEC1010 Installation Category II 100V Phase Earth; Terminal Voltage : >85% of Rated Voltage for Insulation; Resistance Measurement from10% to 100% of the Insulation Resistance Range; Carrying CaseThe Agam AIT 501 is the compact insulation resistance tester with diagnostic features like PI, DAR. When carrying out insulation resistance measurements this device uses test voltages of 500V, 1000V, 2500V and 5000V. At 500V this tester can carry out insulation resistance measurements from 1MOhms to 20GOhms, it carries out this measurement at 5MOhms to 1000GOhms. The tester can also be used to carry out AC/DC voltage measurements  and low resistance testing . The AIT 501 is an autoranging device and will automatically choose the applicable range depending on the test. It also includes a large, backlit LCD screen, auto power down function when left idle and includes a USB interface for using the tester to download data to PC. To accompany USB connectivity the AIT 501 also includes datalogging capabilities. When displaying testing results the AIT 501 uses both numerical and analogue bar graph representation of the test results. It also allows users to carry out comparisons, polarisation index calculations and dielectric absorption calculations. This insulation resistance tester is CAT III 600V, EN 61010-1 and EN 61326-1 compliant.. An ideal tool for Insulation testing designed smartly.All Meco DIT-99D Digital Insulation tester IRT Range 0-200M Ohm are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture Meco DIT-99D Digital Insulation tester IRT Range 0-200M Ohm, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. Meco products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of Meco Insulation Testers Digital insulation resistance meter also known as mega ohmmeter, high voltage insulation resistance tester, etc., for the insulation resistance test. The instrument has a large LCD screen gray backlit display, data storage, data access, alarm, automatic shutdown and other functions. At the same time, it also has the function of measuring DC voltage, AC voltage, absorption ratio and polarization index of DC voltage. The machine is beautiful and upscale, has a wide range, high resolution, convenient operation, easy to carry, accurate, reliable, stable performance, strong anti-interference ability. Moreover, it has a shockproof, dustproof, moisture-proof structure and is a commonly used and indispensable instrument for telecommunications, electricity, meteorology, computer rooms, oil fields, electromechanical installation and maintenance, and industrial enterprises that use electricity as industrial power or energy. It is suitable for measuring the resistance value of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment.At the same time, it can output a variety of different voltage levels with the step-adjusting voltage function (for example, 15KV models can generate 12KV levels, which can be used more widely).MECO DIT-99B Digital Insulation Tester has the following features: 3 Digit 17mm LCD Display; High Accuracy (3% rdg + 2 dgt); Single Person Push Button Operation; Designed to Generally Conform to IS 10656-1983; Meets Requirement of IEC1010 Installation Category II 100V Phase Earth; Terminal Voltage : >85% of Rated Voltage for Insulation; Resistance Measurement from10% to 100% of the Insulation Resistance Range; Carrying Case
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information