SPECIFICATIONS

  • DC Voltage Range :
    1000A Ac/Dc : 30 mV-1000 V
    300A Ac/Dc : 30 mV-1000 V
    Accuracy : ±(0.3 % + 1 Digits)
  • DC Current Range :
    1000A Ac/Dc :  0-1000 A
    300A Ac/Dc :  0-300 A
    Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Range :
    1000A Ac/Dc : 0-1000 A
    300A Ac/Dc : 0-300 A
    Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Resolution :
    1000A Ac/Dc : 0.1 A / 1 A
    300A Ac/Dc : 0.1 A / 1 A
  •  AC Voltage Range:
    1000A Ac/Dc : 0-1000 V
    300A Ac/Dc : 0-1000 V
    Accuracy: ±(0.75 % + 1 Digits)
  •  Resistance Accuracy: ±(0.25 % + 1 Digits)
  •  Capacitance Range: 30 nF-30 µF
  •   Accuracy: ±(3.0 % + 3 Digits)
  •  Frequency: 0-100 kHz
    Accuracy: ±(0.5 % + 1 Digits)
  • Temperature Range :  -200° to 800°C
    Accuracy : ±(1.0 % + 1)
  • Battery Voltage : 9 V DC
  • Operating temperature : -10 to +55°C
  • Storage temperature : -20 to +70°C
  • Relative humidity : 0… 90% non condensing
  • Number of digits : 3 ¾ digits.
  • Maximum count : 3100 counts
  • Weight : 0.6 Kg

FEATURES

  • Large Jaw Opening : For RISH CLAMP 1000A AC-DC Jaw opening of 51mm for standard wire diameter of 50mm and for RISH CLAMP 300A AC-DC Jaw
    opening of 41mm for standard wire diameter of 40mm for 300A
  • Narrow Body : Narrow housing for firm grip and easy to carry.
  • High Accuracy for low current measurement : The clamp meter can measure accurately at not only the High currents but also Low current ranges.
  • User selectable Backlit : It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit.
  • Temperature measurement : Temperatures from -200 to 800 °C using Pt 100 and Pt 1000 sensors.
  • AUTO POWER OFF : In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 15 minutes
  • Analog Scale : Analog scale that updates at the rate 20 times/sec to observe fluctuations in input.
  • CONTINOUS ON MODE : In this mode, AUTO POWER OFF is disabled.
  • DATA Hold Function : By pressing DATA HOLD button, reading on the display can belatched for Hands free operation.
  • MIN,MAX Function : By pressing MIN/MAX button, the clamp meter will start recordinglatest Minimum and Maximum readings
  • NULL ZERO Correction for Resistance : For Low ohm measurement, the lead resistance can be compensated by pressing the shift key (Yellow Key)
  • NULL ZERO Correction for Capacitance : Null zero connection for capacitance. For nF range, stray capacitance can be compensated by shift key (Yellow Key)
  • AUTO and MANUAL ranging modes In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
  • Diode Measurement : For testing diode and transistors, diode measurement function is available.
Category:

Description

RISH Clamp 1000A/300A measures important electrical parameters like AC Current (TRMS), DC Current, AC Voltage(TRMS), and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature measurement.

Reviews

There are no reviews yet.

Be the first to review “RISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsRISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature removeMECO 2502T AUTO BL CLAMPMETER removeMECO-G R-2070C DIGITAL CLAMPMETER removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO 72 AUTO BL CLAMP METER removeMECO 3600+ DIGITAL CLAMPMETER remove
NameRISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature removeMECO 2502T AUTO BL CLAMPMETER removeMECO-G R-2070C DIGITAL CLAMPMETER removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO 72 AUTO BL CLAMP METER removeMECO 3600+ DIGITAL CLAMPMETER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS
  • DC Voltage Range : 1000A Ac/Dc : 30 mV-1000 V 300A Ac/Dc : 30 mV-1000 V Accuracy : ±(0.3 % + 1 Digits)
  • DC Current Range : 1000A Ac/Dc :  0-1000 A 300A Ac/Dc :  0-300 A Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Range : 1000A Ac/Dc : 0-1000 A 300A Ac/Dc : 0-300 A Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Resolution : 1000A Ac/Dc : 0.1 A / 1 A 300A Ac/Dc : 0.1 A / 1 A
  •  AC Voltage Range: 1000A Ac/Dc : 0-1000 V 300A Ac/Dc : 0-1000 V Accuracy: ±(0.75 % + 1 Digits)
  •  Resistance Accuracy: ±(0.25 % + 1 Digits)
  •  Capacitance Range: 30 nF-30 µF
  •   Accuracy: ±(3.0 % + 3 Digits)
  •  Frequency: 0-100 kHz Accuracy: ±(0.5 % + 1 Digits)
  • Temperature Range :  -200° to 800°C Accuracy : ±(1.0 % + 1)
  • Battery Voltage : 9 V DC
  • Operating temperature : -10 to +55°C
  • Storage temperature : -20 to +70°C
  • Relative humidity : 0... 90% non condensing
  • Number of digits : 3 ¾ digits.
  • Maximum count : 3100 counts
  • Weight : 0.6 Kg
FEATURES
  • Large Jaw Opening : For RISH CLAMP 1000A AC-DC Jaw opening of 51mm for standard wire diameter of 50mm and for RISH CLAMP 300A AC-DC Jaw opening of 41mm for standard wire diameter of 40mm for 300A
  • Narrow Body : Narrow housing for firm grip and easy to carry.
  • High Accuracy for low current measurement : The clamp meter can measure accurately at not only the High currents but also Low current ranges.
  • User selectable Backlit : It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit.
  • Temperature measurement : Temperatures from -200 to 800 °C using Pt 100 and Pt 1000 sensors.
  • AUTO POWER OFF : In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 15 minutes
  • Analog Scale : Analog scale that updates at the rate 20 times/sec to observe fluctuations in input.
  • CONTINOUS ON MODE : In this mode, AUTO POWER OFF is disabled.
  • DATA Hold Function : By pressing DATA HOLD button, reading on the display can belatched for Hands free operation.
  • MIN,MAX Function : By pressing MIN/MAX button, the clamp meter will start recordinglatest Minimum and Maximum readings
  • NULL ZERO Correction for Resistance : For Low ohm measurement, the lead resistance can be compensated by pressing the shift key (Yellow Key)
  • NULL ZERO Correction for Capacitance : Null zero connection for capacitance. For nF range, stray capacitance can be compensated by shift key (Yellow Key)
  • AUTO and MANUAL ranging modes In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
  • Diode Measurement : For testing diode and transistors, diode measurement function is available.
SPECIFICATIONS :
  • DC VOLTAGE : 200mV, 2V, 20V, 200V, 1000V
  • AC VOLTAGE : 2V, 20V, 200V, 750V
  • AC CURRENT : 2A, 20A, 200A, 1000A
  • TEMPERATURE : -20 to 750 deg C
  • JAW OPENING : 52mm (max.)
  • RESISTANCE : 200Ω, 2kΩ, 20ΩK, 200kΩ, 2MΩ, 20MΩ
FEATURES : 
  • Auto/Manual Ranging.
  • Temperature, Data Hold.
  • Max, NCV, APO.
SPECIFICATIONS : 
  • AC CURRENT : 600A
  • AC VOLTAGE : 600A
  • DIODE RANGE : 1mV
  • FREQUENCY : 50Hz~400Hz
  • DIMENSION : 185mmx51mmx25mm
  • RESISTANCE : 60M ohms
  • CAPACITANCE : 1000μF
FEATURES: 
  • Op. Current <2mA (no back light).
  • LCD Display,
  • Auto / Manual Ranging, Data Hold.
  • NCV APO, Temperature, Frequency, Max Hold.
  • Diode Test, Resistance, Duty Cycle.
  • Continuity Buzzer, Backlight, Trms.
  • Low Battery Indicated.
SPECIFICATIONS :
  • DC VOLTAGE TEST : 0V~1000
  • AC VOLTAGE TEST : 0V~750
  • BATTERY  VOLTAGE : 1.5 V
  • RESISTANCE : 500 MW/1000 V
  •  TEMPERATURE : -10 to 50 deg C(RH £ 75%)
FEATURES : 
  • Inbuild Protection Circuit to prevent the harm of reverse voltages.
  • LCD Back Light Function with Indicator Switch.
  • 3 Ranges of Insulation Measurement.
SPECIFICATIONS : 
  • DC Voltage : 400 mV-600 V
  • AC Voltage : 0-600 V
  • DC Voltage Accuracy : ?(0.8 % + 3 Digits)
  • AC Voltage Accuracy : ?(1.2 % + 3 Digits)
  • Dimensions : 185?65?28 mm
  • Operating Environment : 0? to 50?C
  • Resistance : 0-40 M?
  • Frequency : 10 Hz-10 MHz
FEATURES : 
  • Low Battery Indicator.
  • Continuity Buzzer, Large & Easy to Read Display.
SPECIFICATIONS : 
  • DC VOLTAGE RANGE : 400 mV-600 V
  • AC VOLTAGE RANGE : 0-600 V
  • DC CURRENT : 0-1200 A
  • AC CURRENT : 0-1000 A
  • DISPLAY : 3¾ Digits LCD Display
  • FREQUENCY : 0-500 kHz
  • CAPACITANCE : 4 nF-40 µF
  • RESISTANCE : 0-40 MΩ
FEATURES : 
  • The Materials Utilized to Manufacture Meco 3600 Super Digital Ac/Dc Clamp Meter 1000 a 600 V.
  • Meco 3600 Digital Ac/Dc Clamp Meter True Rms 1000 a 600 V of the Finest Quality & Rest Assured to Get the Best in Terms of Both Durability & Performance.
ContentRISH Clamp 1000A/300A measures important electrical parameters like AC Current (TRMS), DC Current, AC Voltage(TRMS), and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature measurement.Meco 2502T-AUTO AC Digital Clamp Meter is a great product for those who are looking for a reliable and accurate clamp meter. It is easy to use and has a large LCD display that makes it easy to read. The Meco clamp meter is best for those looking for a reasonably priced, long lasting measurement and testing device. This product is known for its quality and durability, making it a great choice for anyone in the market for a reliable clamp meter.The MECO-G TRMS Clamp Meter is a versatile tool for measuring clamping forces in a variety of applications. With its easy-to-read LCD display, the meter is perfect for use in the laboratory, factory, or field. The Meco-G 35/6 digit 6600 counts LCD Display clamp meter is an accurate and versatile instrument for measuring AC currents and voltages. With six ranges and an ac voltage accuracy of 1.5%+5 digits, this meter can measure currents up to 600A and voltages up to 600V. The dc voltage range can measure currents up to 6V and voltages up to 60V. The Picking Technologies Gauge Clamp Meter is an essential tool for testing and measuring the clamping force of any material.MECO-G Digital Insulation Resistance Tester, R-DT903A is a premium quality product from MECO-G. All MECO-G Digital Insulation Resistance Tester, R-DT903A are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G Digital Insulation Resistance Tester, R-DT903A, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Insulation Testers .All Meco 72-Auto Digital AC Clamp Meter 400 A 600 V are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture Meco 72-Auto Digital AC Clamp Meter 400 A 600 V, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. Meco products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of Meco Clamp Meters .Meco 3600 Super Digital AC/DC Clamp Meter is a great product for those who need a reliable and accurate clamp meter. It is able to measure AC/DC current up to 1000 A and voltage up to 600 V. The Meco 3600-Super digital AC/DC clamp meter is a reliable and precision measurement & testing tool. It has a 3 digits LCD display with a wide viewing angle. The AC current range is 0-1000 A, while the resistance range (ohm) is 0-40 M?. The AC voltage range is 0-600 V and the DC voltage range is 400 mV-600 V.
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information