MECO DIT 99BL-B DIGITAL INSULATIONS TESTER

Brands:

Availability: In Stock

SPECIFICATIONS : 

  • DC VOLTAGE : 250 V
  • RANGES : 0 – 200 M Ohms
  • RESOLUTION : 0.1 M Ohms

FEATURES :

  • Testing insulation is essential to keeping wires and motors working properly.
  • The analog insulation tester will measure the resistance in ohms and will display the results on a dial.
  • It can also be used on the wire insulation, as well as cables and cords.
  • The analog insulation tester is made up of a set of probes that are inserted into the insulation to test the insulation resistance.

Description

MECO DIT-99B Digital Insulation Tester has the following features: 3 Digit 17mm LCD Display; High Accuracy (3% rdg + 2 dgt); Single Person Push Button Operation; Designed to Generally Conform to IS 10656-1983; Meets Requirement of IEC1010 Installation Category II 100V Phase Earth; Terminal Voltage : >85% of Rated Voltage for Insulation; Resistance Measurement from10% to 100% of the Insulation Resistance Range; Carrying Case

Reviews

There are no reviews yet.

Be the first to review “MECO DIT 99BL-B DIGITAL INSULATIONS TESTER”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMECO DIT 99BL-B DIGITAL INSULATIONS TESTER removeMECO DIT 954 DIGITAL INSULATION TESTER removeHTC 6350 IN Insulation Resistance Tester removeRishabh AIT 501 Smart 5KV Digital Insulation Tester removeMECO-G R-DIT945K-1 DIGITAL INSULATION TESTER 100/250/500/1000/2500/5000V removeHIOKI IR-3455 High Voltage Insulation Tester remove
NameMECO DIT 99BL-B DIGITAL INSULATIONS TESTER removeMECO DIT 954 DIGITAL INSULATION TESTER removeHTC 6350 IN Insulation Resistance Tester removeRishabh AIT 501 Smart 5KV Digital Insulation Tester removeMECO-G R-DIT945K-1 DIGITAL INSULATION TESTER 100/250/500/1000/2500/5000V removeHIOKI IR-3455 High Voltage Insulation Tester remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS : 
  • DC VOLTAGE : 250 V
  • RANGES : 0 - 200 M Ohms
  • RESOLUTION : 0.1 M Ohms
FEATURES :
  • Testing insulation is essential to keeping wires and motors working properly.
  • The analog insulation tester will measure the resistance in ohms and will display the results on a dial.
  • It can also be used on the wire insulation, as well as cables and cords.
  • The analog insulation tester is made up of a set of probes that are inserted into the insulation to test the insulation resistance.
SPECIFICATIONS : 
  • TEST VOLTAGE : 1000 V/ 2500 V/ 5000 V
  • OPERATING TEMEPRATURE : 0 to 40 deg C
  • DMENSIONS : 190x155x75 mm
  • RESISTANCE : 0.1M Ohm to 200G Ohms
  • ACCURACY : ±(3% +5 digit) for Insulation Resistance Range RDG
                          ±(2% +5 digit) for AC Voltage Measurment
  • AC VOLTAGE :  0 - 6000 VAC (50-60 Hz)
FEATURES : 
  • Data Holding Function.
  • Display with Annunciators.
  • Auto Range (Insulation Test).
  • Battery Operated with AC Adaptor.
  • With LED Indicators & Beep Facility.
  • Red LED Indicator for HV (High Voltage).
  • Measurement of AC Voltage Upto 600VAC.
  • Range Selection & Single Person Push Button Operation.
  • LCD with Green Back Light Function with Indicator Switch.
  • Measurement of Phase Sequence Between (Phase - Phase Voltage).
  • Inbuilt Protection Circuit to prevent the harm of reverse Voltages.
   
SPECIFICATIONS
  • Testing Voltage : 100/250/500/1000/2500/5000 V
  • OUT VOLTAGE : 90~110% of the test voltage
  • RANGE : 0.1M 20G for 100/250/500 V ; 0.1M 200G for 1000/2500/5000 V
  • RESOLUTION : 0.01MΩ
  • ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 10 digits ; 10~200GΩ ± 10% of rdg + 5 digits
AC VOLTAGE
    • RANGE : 0 – 600V
    • RESOLUTION : 1V
    • ACCURACY : ±2.0% of rdg + 5 digits
FEATURES
  • 3½ Digit Insulation Tester with Backlight
  • 1,999 Count
  • Data Hold
  • Test Range 100 V to 5000 V
  • POWER: AA 1.5V X 8 (Rechargeable Battery)
  • Standard Accessories : Soft Carrying Case, Test Lead, Manual, Power Adaptor,AA 1.5V X 8 (Rechargeable Battery)
  • Dimension : 190(H) x 155(W) x 75(D)mm
SPECIFICATIONS
  • Test Voltages : 500V, 1000V, 2500V, 5000V
  • Test Voltage Accuracy : 0% to 20%
  • 500V Range (Accuracy) : 1MOhm to 20GOhm (± 3%+5)
  • 1000V Range (Accuracy) : 2MOhm to 40GOhm (± 3%+5)
  • 2500V Range (Accuracy) : 5MOhm to 100GOhm (± 3%+5)
  • 5000V Range (Accuracy) : 10MOhm to 1000GOhm (± 3%+5)
  • Short Circuit Current : 1.8 mA
  • AC/ DC Voltage : 600V
  • Low Resistance : 0.1Ohm to 999.9Ohm
  • Operating Temperature : -10 to 40 °C
  • Storage Temperature : -20 to 60° C
  • Relative humidity : 85% @ -10 °C to 40 °C
  • Dimensions  : 202 x 155 x 94 mm
  • LCD Size  : 123mm x 58mm
  • Net Weight: Approx. 2kg (including battery)
FEATURES
  • Robust unit
  • Test voltages of 500V, 1000V, 2500V and 5000V & Insulation Resistance measurement upto 1 T Ohm
  • Automatic Polarisation Index (PI), Dielectric Absorption Ratio (DAR)
  • DC/AC voltage measurements to 600V
  • Autoranging insulation resistance tester
  • Auto shut down when left idle & Optional Operation on Mains via adapter
  • Datalogging capabilities and USB interface
  • Comparator Function
  • Wide LCD with backlit screen, Analog bar graph (30 segment)
SPECIFICATIONS
  • Test Voltage : 100V/250V/500V ±10% Range : 0.1~20MΩ Accuracy : ±(3% + 5dgts) Resolution : 0.01MΩ
  • Test Voltage : 1000V/2500V/5000VDC ±10% Range : 200MΩ~10GΩ Accuracy : ±(5% + 10dgts) Resolution : 0.01MΩ
  • Display : 3½ Dgt. (1999 Counts) Large LCD Display with 29mm Display Height.
  • Accuracy : ±(3% + 5dgts)
  • Operating Temperature : 0°C to 40°C (RH £ 85%)
  • Storage Temperature : -10°C to 50°C (RH £ 75%)
  • Dimensions : 190 x 155 x 75 mm
  • Weight : Approx 900g
  • Power : 12V (8 x 1.5V) (R6AA size batteries) or AC Adaptor 12VDC
FEATURES
  • 3½ Digit (1999 Counts) Large Display with Back light
  • LED Indicator for HV (High Voltage)
  • High Accuracy ±(3% + 2dgts) for Insulation Measurement.
  • In-build Protection Circuit to prevent the damage reverse voltages .
  • LCD Back Light Function with Indicator Switch.
  • Battery Operated / AC adapter
  • 6 Ranges of Insulation Measurement.
  • Display with Annunciators
  • Suitable for calculation PI and DAR (manually)
  • Auto-Ranging (Insulation Measurement)
  • As per IS10656-1983
  • As per EMC standard IEC 61326-1 Class B
  • Over Voltage CAT III, 600V
  • AS per Safety Standard IEC/EN 61010-1 & 61010-31
  • IP-44 Protection
SPECIFICATIONS
  • Test Voltage : 250 V to 5.00 kV DC, (Possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kV)
  • Measurement Range : 0.00 MΩ to 500 GΩ (250 V) 0.00 MΩ to 1.00 TΩ (500 V) 0.00 MΩ to 2.00 TΩ (1 kV) 0.00 MΩ to 5.00 TΩ (2.5 kV) 0.00 MΩ to 10.0 TΩ (5 kV)
  • Measurement Current : 1 mA (Test voltage 250 V to 1.00 kV), 0.5 mA (Test voltage 1.10 kV to 2.50 kV) 0.25 mA (Test voltage 2.60 kV to 5.00 kV), Short-circuit current: 2 mA or less
  • Resistance Range : 10 MΩ to 10 TΩ, 7 ranges (auto range)
  • Accuracy : ±5% rdg. ±5 dgt. Up to [Test voltage (setting value)/Resistance measurable at 100 nA] ±20% rdg. ±5 dgt. [Test voltage (setting value)/Resistance measurable at 100 nA] to [Test voltage (setting value)/Resistance measurable at 1 nA] or 500 GΩ ±30% rdg. ±50 dgt. [Test voltage (setting value)/Resistance measurable at 1 nA] or 501 GΩ to 9.99 TΩ
  • Leakage current measurement : 1.00 nA to 1.20 mA, 6 ranges (current measurement that occurs when test voltage is generated) Accuracy ±2.5% rdg. ±5 dgt. (1 mA range); refer to complete catalog for other ranges
  • Voltage measurement : ±50 V to ±1.00 kV DC, 50 V to 750 V AC (50/60 Hz), Accuracy: ±5 % rdg. ±5 dgt. , Input resistance: Approx. 10 MΩ
  • Temperature measurement : -10.0 ˚C to 70.0 ˚C, 3 ranges (used with optional sensor) Accuracy ±1.0 ˚C (0.0 ˚C to 40.0 ˚C); refer to complete catalog for other ranges
  • Other Functions : Insulation Diagnosis (Temperature compensation, PI/DAR display, Step voltage test), Data memory, Communication (USB 2.0, PC application software), auto discharge, hot conductor warning indication, etc.
  • Digital LCD, max. 999 dgt. with backlight, Bar graph display
  • Dimensions and Mass : 260 mm (10.24 in)W × 250.6 mm (9.87 in)H × 119.5 mm (4.70 in)D, 2.8 kg (98.8 oz)
  • Included Accessories : Test lead 9750-01 ×1, Test lead 9750-02 ×1, Test lead 9750-03 ×1, Alligator clip 9751-01 ×1, Alligator clip 9751-02 ×1, Alligator clip 9751-03 ×1, Instruction manual ×1, LR6 (AA) alkaline batteries ×6, USB cable ×1, PC application software (CD-R) ×1
FEATURES
  • Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
  • Wide testing voltage range, up to 5.00 kV from 250 V DC
  • Wide measurement insulation range, up to 10 TΩ
  • PI (Polarization Index) and DAR (Dielectric Absorption Ratio) automatically calculated / display
  • Extended operating temperature range of -10°C to 50°C
  • Data memory function to reduce handwritten notes
  • Bright LED luminous scale
ContentMECO DIT-99B Digital Insulation Tester has the following features: 3 Digit 17mm LCD Display; High Accuracy (3% rdg + 2 dgt); Single Person Push Button Operation; Designed to Generally Conform to IS 10656-1983; Meets Requirement of IEC1010 Installation Category II 100V Phase Earth; Terminal Voltage : >85% of Rated Voltage for Insulation; Resistance Measurement from10% to 100% of the Insulation Resistance Range; Carrying CaseMECO DIT-954 Digital Insulation Tester has the following features: 3 1/2 Digit (1999 Counts) Lage LCD Display; High Accuracy; Range Selection & Single Person Push Button Operation; LCD Back Light Function with Indicator Switch; Data Holding Function Function Icons on Display; Measurement of AC Voltage upto 600VAC; Measurement of Phase Sequence between (Phase-Phase Voltage)with LED Indicator; Auto Range (Insulation Test); LED Indicator for High Voltage; Inbuilt Protection Circuit to prevent the harm of reverse voltages; Battery Operated with AC Adaptor; 3 Ranges of Voltage & Insulation ResistanceThe Agam AIT 501 is the compact insulation resistance tester with diagnostic features like PI, DAR. When carrying out insulation resistance measurements this device uses test voltages of 500V, 1000V, 2500V and 5000V. At 500V this tester can carry out insulation resistance measurements from 1MOhms to 20GOhms, it carries out this measurement at 5MOhms to 1000GOhms. The tester can also be used to carry out AC/DC voltage measurements  and low resistance testing . The AIT 501 is an autoranging device and will automatically choose the applicable range depending on the test. It also includes a large, backlit LCD screen, auto power down function when left idle and includes a USB interface for using the tester to download data to PC. To accompany USB connectivity the AIT 501 also includes datalogging capabilities. When displaying testing results the AIT 501 uses both numerical and analogue bar graph representation of the test results. It also allows users to carry out comparisons, polarisation index calculations and dielectric absorption calculations. This insulation resistance tester is CAT III 600V, EN 61010-1 and EN 61326-1 compliant.. An ideal tool for Insulation testing designed smartly.“MECO-G” has introduced a new & advanced multi-range 3½ Dgt. (1999 Counts) Digital Insulation Tester Model: R-DIT945K-1. It has 6 Voltage Ranges i.e. 100V/250V/500V/1000V/2500V/5000V. R-DIT945K-1 has three Ohms (W) ranges, 0-200MW, 200MW-10GW and 10GW-2000GW.IR3455Hioki insulation resistance testers or megohmmeters feature all-in-one designs including built-in rugged cases and test lead storage compartments. The IR3455 is a 5-range, 250 V to 5000 V digital insulation resistance tester offering up to 10 TΩ of insulated resistance testing.  High performance features include bargraph, built-in memory, leak current and voltage testing, and DAR and PI calculation capabilities to help shorten work time associated with field insulation testing.
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information