SPECIFICATIONS 

  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
    Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
    Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
    Defined Accuracy Range :  0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
    *Harmonics can be displayed with our free app GENNECT Cross
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2

FEATURES 

  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • CAT IV 300 V
    CAT III 600 V
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Solve GFCI and RCD problems quickly
  • Broad measurement range extending from leakage currents to load currents
  • Speed up pass/fail judgments with the built-in comparator function

Reviews

There are no reviews yet.

Be the first to review “HIOKI CM4002 AC LEAKAGE CLAMP METER”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHIOKI CM4002 AC LEAKAGE CLAMP METER removeMECO G R-1818T DIGITAL CLAMP METER removeMECO 72 AUTO BL CLAMP METER removeMECO-G R-2700T DIGITAL CLAMPMETER removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO DT-2250Hz AUTO DIGITAL CLAMPMETER remove
NameHIOKI CM4002 AC LEAKAGE CLAMP METER removeMECO G R-1818T DIGITAL CLAMP METER removeMECO 72 AUTO BL CLAMP METER removeMECO-G R-2700T DIGITAL CLAMPMETER removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO DT-2250Hz AUTO DIGITAL CLAMPMETER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS 
  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Accuracy : 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Accuracy : 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt Defined Accuracy Range :  0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio *Harmonics can be displayed with our free app GENNECT Cross
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES 
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • CAT IV 300 V CAT III 600 V
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Solve GFCI and RCD problems quickly
  • Broad measurement range extending from leakage currents to load currents
  • Speed up pass/fail judgments with the built-in comparator function
SPECIFICATIONS : 
  • AC VOLTAGE : 750V
  • DC VOLTAGE : 1000V
  • AC CURRENT : 1000A
  • DC CURRENT : 1000A
  • RESISTANCE : 60M
  • CAPACITANCE : 1000µF
  • TEMPERATURE : -0 F~1832ºF
FEATURES : 
  • DISPLAY : 3 5/6 DIGIT DISPLAY
  • POLARITY : AUTO POLARITY
  • SAMPLING RATE : 2~3 TIMES/SECOND
  • POWER : 3V BETTERY
  • JAW OPENING : 50mm
 
SPECIFICATIONS : 
  • DC Voltage : 400 mV-600 V
  • AC Voltage : 0-600 V
  • DC Voltage Accuracy : ?(0.8 % + 3 Digits)
  • AC Voltage Accuracy : ?(1.2 % + 3 Digits)
  • Dimensions : 185?65?28 mm
  • Operating Environment : 0? to 50?C
  • Resistance : 0-40 M?
  • Frequency : 10 Hz-10 MHz
FEATURES : 
  • Low Battery Indicator.
  • Continuity Buzzer, Large & Easy to Read Display.
SPECIFICATIONS :
  • DC VOLTAGE : 1000V
  • AC VOLTAGE : 750V
  • AC CURRENT : 300A
  • RESISTANCE : 60M ohms
  • FREQUENCY : 50⁓1KHz
  • TEMPERATURE : -40~2000℉
  • CAPACITANCE : 60nF/600nF/6µF/60µF/400µ/20mF
FEATURES :
  • TRANSFORMER JAWS
  • TRIGGER
  • RANGE BUTTONS
  • Hz/DUTY BUTTON
  • "COM" TERMINAL
  • DATA HOLD /BCKLIGHT BUTTON
  • INPUT TERMINAL
  • FUNCTION SWITCH/RANGE SWITCH
  • SELECT BUTTON
SPECIFICATIONS :
  • DC VOLTAGE TEST : 0V~1000
  • AC VOLTAGE TEST : 0V~750
  • BATTERY  VOLTAGE : 1.5 V
  • RESISTANCE : 500 MW/1000 V
  •  TEMPERATURE : -10 to 50 deg C(RH £ 75%)
FEATURES : 
  • Inbuild Protection Circuit to prevent the harm of reverse voltages.
  • LCD Back Light Function with Indicator Switch.
  • 3 Ranges of Insulation Measurement.
SPECIFICATIONS : 
  • DC VOLTAGE RANGE : 4-1000 V (Auto Ranging)
  • AC VOLTAGE RANGE : 4 to 750V (Auto Ranging)
  • AC VOLTAGE : 4V, 40V, 400V, 750V (Auto) (40-500Hz)
  • DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
  • FREQUENCY  RANGE : 10 Hz, 50 Hz & 500 Hz
  • FREQUENCY ACCURACY : ±(0.5% rdg + 2 dgt)
  • RESISTANCE : 400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (Auto)
  • DIMENSION : 250x98x35 mm
FEATURES : 
  • Automatic.
  • 3 V Sensitivity.
  • Select Button.
  • Data Hold Button.
  • Audible Continuity Check.
  • Diode Test Functions.
  • Low Battery Indications.
  • Over Volt Protections 200V DC and AC Peak.
  • Automatic, Positive Implied, Negative Polarity Indication.
ContentAll Meco 72-Auto Digital AC Clamp Meter 400 A 600 V are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture Meco 72-Auto Digital AC Clamp Meter 400 A 600 V, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. Meco products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of Meco Clamp Meters .MECO-G Digital Insulation Resistance Tester, R-DT903A is a premium quality product from MECO-G. All MECO-G Digital Insulation Resistance Tester, R-DT903A are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G Digital Insulation Resistance Tester, R-DT903A, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Insulation Testers .Meco Digital Clamp Meter 2250-HZ comes with an assortment of features like data hold diode test data hold and % duty cycle. It is equipped with 2250-Hz Auto 10000A AC 3 digit 3999 counts APO frequency and data hold.
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information