SPECIFICATIONS 

  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
    Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
    Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
    Defined Accuracy Range :  0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
    *Harmonics can be displayed with our free app GENNECT Cross
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2

FEATURES 

  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • CAT IV 300 V
    CAT III 600 V
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Solve GFCI and RCD problems quickly
  • Broad measurement range extending from leakage currents to load currents
  • Speed up pass/fail judgments with the built-in comparator function

Reviews

There are no reviews yet.

Be the first to review “HIOKI CM4002 AC LEAKAGE CLAMP METER”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHIOKI CM4002 AC LEAKAGE CLAMP METER removeMECO G R-1818T DIGITAL CLAMP METER removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeHTC CL-2054 10uA high Resolution AC Leakage Current Tester 40mA ~ 100A removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO-G R-2070D DIGITAL CLAMPMETER remove
NameHIOKI CM4002 AC LEAKAGE CLAMP METER removeMECO G R-1818T DIGITAL CLAMP METER removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeHTC CL-2054 10uA high Resolution AC Leakage Current Tester 40mA ~ 100A removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO-G R-2070D DIGITAL CLAMPMETER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS 
  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Accuracy : 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Accuracy : 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt Defined Accuracy Range :  0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio *Harmonics can be displayed with our free app GENNECT Cross
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES 
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • CAT IV 300 V CAT III 600 V
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Solve GFCI and RCD problems quickly
  • Broad measurement range extending from leakage currents to load currents
  • Speed up pass/fail judgments with the built-in comparator function
SPECIFICATIONS : 
  • AC VOLTAGE : 750V
  • DC VOLTAGE : 1000V
  • AC CURRENT : 1000A
  • DC CURRENT : 1000A
  • RESISTANCE : 60M
  • CAPACITANCE : 1000µF
  • TEMPERATURE : -0 F~1832ºF
FEATURES : 
  • DISPLAY : 3 5/6 DIGIT DISPLAY
  • POLARITY : AUTO POLARITY
  • SAMPLING RATE : 2~3 TIMES/SECOND
  • POWER : 3V BETTERY
  • JAW OPENING : 50mm
 
SPECIFICATIONS:
  • DC Voltage: 2000V
  • AC Voltage: 2000V
  • DC Current: 2000A
  • AC Current: 2000A
  • Resistance: 20 M ohms
  • Capacitance: 2000uF
  FEATURES
  • Display Mode: Display by LCD
  • Maximum Display: 1999
  • Digits: 3 ½ Digits
  • Maximum span of jaw: 55mm
  • Auto Range
  • Inrush Current
  • Resistance
  • Capacitance
  • Diode Test
  • Continuity Test
  • Data Hold
  • LED Testing
  • Back Light + Lamp Light
  • Auto negative polarity indication: displaying ‘-’
  • Auto Power Off
  • Battery: 9V
 
 Specification
  • AC Voltage: 400V
  • AC  Current: 40mA/400mA/4A/40A/80A/80-100A
  • Resistance Range: 40-400 Ohms
  • CONTINUITY TEST : Threshold 40Ω, Continuity Beeper 2.5KHz
FEATURES
  • 3¾ Digit Manual Range
  • 3,999 Count
  • 10uA high Resolution
  • Auto Power Off (APO)
  • Shielded Transformer Jaw Open to 1.2”
  • POWER: 9V (6F22) X 1
  • Standarrd Accesories :Hard Carrying Case, Test Lead, Manual
  • Dimension : 209(H) x 43(W) x 30(D)mm
SPECIFICATIONS :
  • DC VOLTAGE TEST : 0V~1000
  • AC VOLTAGE TEST : 0V~750
  • BATTERY  VOLTAGE : 1.5 V
  • RESISTANCE : 500 MW/1000 V
  •  TEMPERATURE : -10 to 50 deg C(RH £ 75%)
FEATURES : 
  • Inbuild Protection Circuit to prevent the harm of reverse voltages.
  • LCD Back Light Function with Indicator Switch.
  • 3 Ranges of Insulation Measurement.
SPECIFICATIONS :
  • DC CURRENT  : 600A
  • AC CURRENT : 600A
  • AC VOLTAGE : 600V
  • DC VOLTAGE : 600V
  • DISPLAY : 3 5/6 digit,6000
  • BETTERY : 9V (6F22)
  • TEMPERATURE : 600°C
  • CAPACITANCE : 1000uF
  • FREQUENCY : 10 MHz
  • RESISTANCE : 60MΩ
    FEATURES:
  • Op. Current <2mA (no back light).
  • LCD Display,
  • Auto / Manual Ranging, Data Hold.
  • NCV APO, Temperature, Frequency, Max Hold.
  • Diode Test, Resistance, Duty Cycle.
  • Continuity Buzzer, Backlight, Trms.
  • Low Battery Indicated.
  • Duty Cycle : 0.1% - 99.9%.
   
ContentB-6096 is a 2000V AC/DC and 2000A AC/DC TRUE RMS Digital Clamp meter. It adopts high performance MCU processor. It is of great value as it has high reliability, accuracy, quality and automatic setting range function. The product has a large digital display, full range overload protection, data hold function, under voltage detection, auto shut off function. The TRUE RMS function can accurately measure frequency voltage, suitable for measuring motor and compressor starting current. Along with AC/DC current, AC/DC voltage it can measure resistance, capacitance, continuity test, diode forward voltage drop, LED operating voltage, and other parameters. This instrument is easy to operate and carry making it an ideal tool for electrical measurement. Especially suitable for measuring large currents and starting currents.    HTC CL-2054 AC Leakage Current Tester is a premium quality product from HTC. All HTC CL-2054 AC Leakage Current Tester are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture HTC CL-2054 AC Leakage Current Tester, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. HTC products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of HTC Leakage Testers .MECO-G Digital Insulation Resistance Tester, R-DT903A is a premium quality product from MECO-G. All MECO-G Digital Insulation Resistance Tester, R-DT903A are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G Digital Insulation Resistance Tester, R-DT903A, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Insulation Testers .MECO-G TRMS Clamp Meter, R-2070D is a premium quality product from MECO-G. All MECO-G TRMS Clamp Meter, R-2070D are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G TRMS Clamp Meter, R-2070D, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Clamp Meters .
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information