Description | SPECIFICATIONS
- Current AC
Range : 40.00 A, 600.0 A
Resolution : 0.01 A, 0.1 A
Accuracy : 2.5% ±5 digit (60-500 Hz) {600 A}
- Current DC
Range : 40.00 A, 600.0 A
Resolution : 0.01 A, 0.1 A
Accuracy : 1.5% ±5 digit (600 A)
- Voltage AC
Range : 600V
Resolution : 0.1 V
Accuracy : 1.5% ±5 digit (20-500Hz)
- Voltage DC
Range : 600V
Resolution : 0.1 V
Accuracy : 1% ±4 digit
- Resistance
Range : 400.0 Ω, 4000 Ω
Resolution : 0.1 Ω, 1 Ω
Accuracy : 1% ±5 digit
- Continuity : ≤ 30 Ω
- Operating Temperature : 14°F to 122°F (-10 °C to 50 °C)
- Storage Temperature : -40 °F to 140 °F (-40 °C to 60 °C)
- IP Rating : IP40
- Storage Altitude : 7 miles (12,000 meters) above mean sea level
- Operating Altitude : 1 mile (2000 meters) above mean sea level
- Digit Display : 6000 count resolution
- Size : 9.21 in x 2.95 in x 1.37 in
- Jaw Size : 1.45 in (37 mm)
- Weight : 384G
FEATURES
- Unique 40A high-precision low current measurement--0.01A high-resolution, 1.6% high-precision measurement
- The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
- The large backlight display facilitates readings in dark environments
- Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
- Current frequency measurement
- Precision down to 0.01A and 0.1V
- 1000A/600A AC/DC current measurement (319/317)
- 600V AC/DC voltage measurement
- 4000Ω resistance measurement
- Continuity beeper
- Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
- One year warranty
| SPECIFICATIONS :
- DC VOLTAGE : 600V
- AC VOLTAGE : 600V
- AC CURRENT : 400A
- RESISTANCE : 20MV
- STORAGE TEMPERATURE : -20°C to 60°C, 0 to 80% R.H.
- OPERATING ENVIORNMENT : 0°C to 50°C at < 70% relative humidity.
- Dimensions : 185 x 65 x 28mm
- Weight : 170gms including battery.
FEATURES:
- DISPLAY : 3½ digit liquid crystal display (LCD)
- LOW BATTERY INDICATION : is displayed when the battery voltage drops below the operating level.
- Weight : 170gms including battery (approx.)
- Maximum Jaw : 25mm
| SPECIFICATIONS :
- DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
- AC VOLTAGE : 4V, 40V, 400V, 750V
- AC CURRENT : 40A-400A
- ACCESORIES : Two 1.5 'AAA' size batteries
- RESISTANCE : 000, 4kQ, 40KQ, 400kQ, 4MQ, 40MQ (auto ranging)
FEATURES :
- 1000A AC auto ranging. 3 digit 3999 counts. Data hold, frequency, capacitance. APO ranges.
| SPECIFICATIONS :
- DC VOLTAGE : 400 mV-600 V
- AC VOLTAGE : 0-600 V
- AC CURRENT : ?(2.5 % + 5 Digits)
- DC CURRENT : ?(0.8 % + 3 Digits)
- DC ACCURACY : ?(0.8 % + 3 Digits)
- AC ACCURACY : ?(1.2 % + 3 Digits)
FEATURES :
- Auto Power off.
- Data Hold Function.
- Audible Continuity Test.
- Diode Test Functions.
- Low Battery Indications.
- Function Button, Hold Button & Rel Button.
| SPECIFICATIONS :
- DC VOLTAGE RANGE : 4-1000 V (Auto Ranging)
- AC VOLTAGE RANGE : 4 to 750V (Auto Ranging)
- AC VOLTAGE : 4V, 40V, 400V, 750V (Auto) (40-500Hz)
- DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
- FREQUENCY RANGE : 10 Hz, 50 Hz & 500 Hz
- FREQUENCY ACCURACY : ±(0.5% rdg + 2 dgt)
- RESISTANCE : 400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (Auto)
- DIMENSION : 250x98x35 mm
FEATURES :
- Automatic.
- 3 V Sensitivity.
- Select Button.
- Data Hold Button.
- Audible Continuity Check.
- Diode Test Functions.
- Low Battery Indications.
- Over Volt Protections 200V DC and AC Peak.
- Automatic, Positive Implied, Negative Polarity Indication.
| SPECIFICATIONS :
- DC VOLTAGE : 1000V
- AC VOLTAGE : 750V
- AC CURRENT : 300A
- RESISTANCE : 60M ohms
- FREQUENCY : 50⁓1KHz
- TEMPERATURE : -40~2000℉
- CAPACITANCE : 60nF/600nF/6µF/60µF/400µ/20mF
FEATURES :
- TRANSFORMER JAWS
- TRIGGER
- RANGE BUTTONS
- Hz/DUTY BUTTON
- "COM" TERMINAL
- DATA HOLD /BCKLIGHT BUTTON
- INPUT TERMINAL
- FUNCTION SWITCH/RANGE SWITCH
- SELECT BUTTON
|
Content | The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 317and 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc. | This Meco Digital Clamp Meter is an auto-ranging clamp meter having a massive 2000 count of 3.5 digits. In addition, one of the biggest advantages of this automated Meco clamp meter is that it can hold a large quantity of data too. The clamp meter has an LCD display and also comes with an auto power-off function. It displays OT and -OI both, and this clamp meter has a function button, hold button and max button. This clamp meter is automatic, positive implied and negative polarity indication. | Meco Digital Clamp Meter 3150 comes with a number of interesting features such as 3 digit 3999 counts frequency data hold APO ranges and capacitance. It comes with a resistance of 4000 4kQ 40KQ 400kQ 4MQ 40MQ. Highly rated by technical experts this digital clamp meter from Meco is suitable for use in DIY projects as well as industries. |
All Meco 72T-Auto Digital AC Clamp Meter 400 A 600 V are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture Meco 72T-Auto Digital AC Clamp Meter 400 A 600 V, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. Meco products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of Meco Clamp Meters .
| Meco Digital Clamp Meter 2250-HZ comes with an assortment of features like data hold diode test data hold and % duty cycle. It is equipped with 2250-Hz Auto 10000A AC 3 digit 3999 counts APO frequency and data hold. | |
Reviews