A thermal imaging camera (colloquially known as a TIC) is a type of the thermographic camera used in firefighting. By rendering infrared radiation as visible light, such cameras allow firefighters to see areas of heat through smoke, darkness, or heat-permeable barriers. Thermal imaging cameras are typically handheld, but may be helmet-mounted. They are constructed using heat- and water-resistant housings, and ruggedized to withstand the hazards of fireground operations.

Showing all 6 results

  • BOSCH GTC 400 C PROFESSIONAL THERMAL CAMERA

    SPECIFICATIONS

    • Measuring application : Thermal image
    • Battery voltage : 12
    • Measurement range : -10 °C to +400 °C
    • Measuring accuracy of IR : ± 3.0 °C* (*plus use-dependent deviation)
    • Data Transfer : MicroUSB, Wi-Fi
    • Thermal sensitivity (NETD) : <50 mK
    • Resolution : 0.1 °C
    • Size of IR sensor : 160×120 px
    • Number of measuring points : 19200
    • Field of view (FOV) : 53×43 °
    • Power supply and runtime : 4 x 1.5 V LR6 (AA) 1 x GBA 12V 1 x GBA 10.8V
    • Frame buffer (number of images)  : 500
    • Memory type : Internal memory
    • File format of image : .jpg
    • Dust and splash protection : IP 53
    • Weight : 0.54Kg

    Features

    • Fast exchange of data and easy documentation of thermal images with the Bosch Thermal App
    • Picture-in-picture technology overlays thermal and real images for easy-to-see localisation of the measurement
    • Flexible battery system can be powered by a 12 V LI-ION battery or with standard alkaline batteries
    Read more
  • BOSCH THERMAL IMAGER GTC-400C Professional

    TECHNICAL DETAILS 

    • Measurement Range : -10 °C to +400 °C
    • Measuring accuracy of IR : ± 3.0 °Cᵇ
    • Battery voltage : 12.0 V
    • Thermal sensitivity (NETD) : <50 mK
    • Resolution : 0.1 °C
    • Size of IR Sensor : 160×120 px
    • Number of measuring points : 19200
    • FOV Field of View : 53×43 °
    • Power supply and runtime : 4 x 1.5 V LR6 (AA) 1 x GBA 12V 1 x GBA 10.8V
    • Frame buffer (number of images) : 500
    • Memory type : Internal memory
    • File format of image : .jpg
    • Data transfer : MicroUSB, Wi-Fi
    • Dust and splash protection : IP 53
    • Weight : 0.54 kg
    • Size of display : 3,5″
    • Operating temperature : -10 – 45 °C
    • Storage temperature : -20 – 70 °C
    • Focus distance, minimum : 0.3m
    • Measuring application : Thermal image
    Read more
  • Fluke VT06 Visual IR Thermometer

    SPECIFICATIONS

    • Infrared resolution : 120×90
    • IR frequency band : 7.5~14 μm(long wave)
    • Frame Rate : 9 Hz
    • Thermal sensitivity/NETD : <60 mk
    • Field of view (H x V) : 50° x 37.5°
    • Spatial resolution : 7.6 mrad
    • Focus system : Focus free
    • Minimum focusing distance : 0.5 m (19.7 in)
    • Temperature Range : -20 °C to 400 °C ; [-4 °F to 752 °F] (not specified for below -10 °C)
    • Temperature Accuracy : ±2°C or 2% @ 23°C±5°C, whichever is greater
    • Emissivity : Adjustable
    • Operating temperature : -10 °C to 50 °C
    • Storage temperature : -40 °C to 70 °C
    • Operating altitude : 2000 m (1.24 mi)
    • Storage Altitude : 12000 m (7.5 mi)
    • Display : 6.096 cm (2.4-inch) LCD
    • Size : 20.4 cm x 6.6 cm x 7.6 cm
    • Weight : 0.36Kg
    • Safety Standard : IEC 61010-1: Pollution Degree 2

    FEATURES 

    • 120 x 90 resolution for more details
    • Wide temperature range, -20°C to 400°C
    • IP65 rated for dust and water proof, 2m drop test, suitable for harsh industrial environments
    • Quickly locate the measured target with built-in laser pointer
    • 2 hours charging time, 8 hours battery life
    • Single-level menu interface, Open-and-View
    Read more
  • Fluke VT08 Visual IR thermometer

    SPECIFICATIONS

    • Infrared resolution : 120×90
    • IR frequency band : 7.5~14 μm(long wave)
    • Frame Rate : 9 Hz
    • Thermal sensitivity/NETD : <60 mk
    • Field of view (H x V) : 50° x 37.5°
    • Spatial resolution : 7.6 mrad
    • Focus system : Focus free
    • Minimum focusing distance : 0.5 m (19.7 in)
    • Visible resolution : 320×240
    • Visible FOV (H x V) : 53° x 41°
    • Temperature Range : -20 °C to 400 °C ; [-4 °F to 752 °F] (not specified for below -10 °C)
    • Temperature Accuracy : ±2°C or 2% @ 23°C±5°C, whichever is greater
    • Emissivity : Adjustable
    • Operating temperature : -10 °C to 50 °C
    • Storage temperature : -40 °C to 70 °C
    • Operating altitude : 2000 m (1.24 mi)
    • Storage Altitude : 12000 m (7.5 mi)
    • Display : 6.096 cm (2.4-inch) LCD
    • Size : 20.4 cm x 6.6 cm x 7.6 cm
    • Weight : 0.36Kg
    • Safety Standard : IEC 61010-1: Pollution Degree 2

    FEATURES 

    • 120 x 90 resolution for more details
    • Wide temperature range, -20 °C to 400 °C
    • Blends a visual image with infrared heat image overlay in real-time to clearly distinguish the measured target
    • IP65 rated for dust and water proof, 2m drop test, suitable for harsh industrial environments
    • Quickly locate the measured target with built-in laser pointer
    • 2 hours charging time, 5 hours battery life
    • Single-level menu interface, Open-and-View
    Read more
  • HTC VT-100 Thermal Imager Camera

    SPECIFICATIONS

    • Display : 2.5”colour LCD
    • IR Solution : 3600 Pixels
    • Visible Light Image & Resolution : 300000 Pixels
    • Field of view : 20×20˚
    • Thermal sensitivity : 0.15˚C/0.27˚F
    • Temperature range : -20~300˚C/-4~572˚F
    • Accuracy : ±2% or reading±2˚C/3.6˚F
    • Emissivity : Adjustable 0.1~1.0
    • Image frequency : 6hz
    • Spectral band : 8-14um
    • Relative Humidity : 10~80%RH
    • Storage Temperature : -20~55˚C/-4~131˚F

    FEATURES

    • TFT Coloure lcd display
    • Adjustable emissivity and reflected background compensation improves measurement accuracy on semi-reflective surface
    • Hot and Cold spot temperature markers that guide the user to the hottest and coldest regions in the infrared heat map
    • Select Coloure palette
    • Visual and heat map image alignment
    • Image capture and save it in SD Card
    • Power : AA 1.5V X 4
    • Battery life : 6Hrs.
    • Weight : 310g
    • Dimension : 223(H) x 88(W) x 65(D)mm
    Read more
  • MECO TIC-300 THERMAL IMAGER

    SPECIFICATIONS

    • Display : 2.4″ Color Display
    • Resolution : 60 X 60
    • Total Pixels : 3600
    • FOV / Shortest Focal Lenght : 20° x 20° / 0.5m
    • Thermal Sensitivity : 0.15°C
    • Measuring Mode : Infrared Focal Plane Measuring Termperature
    • Temperature Range : -20°C ~ 300°C (-4°F ~ 572°F)
    • Measuring Accuracy : ±2% digital / ±2°C
    • Wavelength Range : 8 ~ 14µm
    • Image Capturing Frequency : 6HzEmissivity : 0.1 ~ 1.0 (Adjustable)
    • Focus Mode : Fixed
    • Palette : iron Red Color, Rainbow, Rainbow High Contrast, Grey Scale (White Glow) and Grey Scale (Black Glow)
    • Image Storage : Card (4GB)
    • Memory Card : Micro SD Card (installed)
    • File Format : BMP
    • Set Control : Unit Adjustment / Language / Date Time Format / Automatic Shut Down

    APPLICATIONS

    • Predictive Maintenance of Electrical Equipment
    • Transport Industry and Car Maintenance
    • Electronic & Electrical Manufacturing
    • Archaeological Study
    • Automotive Manufacturing
    • Furnace & Smelting

     

    Read more