Earth resistance testers allow the measurement of earth or ground electrode resistance and soil resistivity. Such measurements are necessary to ensure an adequate low resistance ground connection which is essential to both the protection and performance of any electrical system.

Showing all 9 results

  • CIE DET-2000 Digital Earth Tester

    SPECIFICATIONS

    • Display : 3.5 digits,L.C.D
    • Accuracy :
      0% to 10% of the range…….+3%
      10% to 90% of the range……+1.5%
      90% to 100% of the range……+3%
    • H.V Test : 2KV AC For 1 min. Between electrical circuit and containing case
    • Insulation Resistance Test : More than 25M Ohm at 500V dc between electrical circuit

    FEATURES

    • Rugged ABS Body
    • 0-10 — 1000 Ohm
    • Easy to use hand held meter
    • Ni-cd rechargeable cells
    • Facility as to make bench top type instrument
    • Four terminals
    • Designed to measure the resistance of earth used in power circuit
    Read more
  • HIOKI FT-6031-50 Earth Tester

    SPECIFICATIONS 

    • Measurement System : Two-electrode method/three-electrode method (switchable)
    • Measurement range / Accuracy :
      20 Ω (0 Ω〜20.00 Ω) / ±1.5% rdg ±8 dgt
      200 Ω (0 Ω〜200.0 Ω) / ±1.5% rdg ±4 dgt
      2000 Ω (0 Ω〜2000 Ω) / ±1.5% rdg ±4 dgt
    • Earth voltage : 0〜30.0 V rms
      Accuracy : ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC)
    • Allowable earth potential : 25.0 V rms (DC or sine wave)
    • Dustproof and waterproof : IP65/IP67 (EN60529)
    • Dimensions : 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D
    • Mass : 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories)

    FEATURES

    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
    • Excellent noise resistance
    • IP67 protected – top of the industry
    • Minimize cabling time with innovative earthing rods and cable winder
    • Wide 0Ω to 2000Ω measurement range
    • Test all ground types from Class A to Class D with a single meter
    Read more
  • HIOKI FT6380-50 Clamp On Earth Tester

    SPECIFICATIONS

    • Earth Resistance Range : 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω,
      Accuracy: ±1.5 % rdg. ±0.02 Ω
    • AC Current Range : 20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA,
      Accuracy: ±2.0 % rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less)
    • Maximum input current (Current measurement) : 100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50 Hz/60 Hz, requires derating at frequency)
    • Maximum rated terminal-to-ground voltage : 600 VAC measurement category IV (anticipated transient overvoltage 8000 V)
    • Memory Function : 2000 data
    • Alarm Function : For resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold.
    • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
      *Harmonics can be displayed with our free app GENNECT Cross.
    • Other functions : Data hold, Backlight, Filter, Auto power save, Wireless communication (without Z3210 installed))
    • Display : LCD, Max. 2,000 count Display refresh rate: Approx. 2 times/sec
    • Dustproof and Waterproof : IP40 (EN60529) With Jaws Closed
    • Power Supply : LR6 alkaline battery × 2
    • Continuous Operating Time : Approx. 40 hours (25 Ω measurement, backlight off, without Z3210 installed)
      Approx. 35 hours (25 Ω measurement, backlight off, with Z3210 installed and using wireless communications)
    • Maximum measurable conductor diameter : φ 32 mm (1.26 in)
    • Dimensions : 73 mm (2.87 in) W × 218 mm (8.58 in) H × 43 mm (1.69 in) D
    • Mass : 620 g (21.9 oz)
    • Included Accessories : Carrying case, Resistance check loop (1 Ω±2%, 25Ω±1%), Strap, LR6 alkaline battery × 2, Instruction manual

    FEATURES

    • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
    • Measure load current up to 60.0 A range
    • Clamp at the narrowest point
    • Earth resistance measurement for multi-grounded systems
    • Measure leak current with absolute certainty with highly sensitive 0.01 mA resolution (at 20.00 mA range)

    Measurement Principle : Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated
    Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value.

    Read more
  • HTC CE-8200 , CE-8202 , CE-8203 Clamp On Ground Earth Resistance Tester

    SPECIFICATIONS

    • Model : CE-8200
      Resistance Range : 0 – 1000Ω
    • Model : CE-8202
      Resistance Range : 0 – 1200Ω
    • Model : CE-8203
      Resistance Range : 0 – 200Ω
    • Resistance :
      Range : 0.010~0.099Ω To 900~1200Ω
      Resolution : 0.001Ω To 30Ω
    • Ambient Temperature and Humidity : 23℃±5℃, below 75%rh
    • Jaw Size : 55 mm X 32 mm
    • LCD Size : 46mm×29mm
    • Dimensions : 285mm× 85mm×58mm
    • Measure Time : 2 times/sec
    • Working temperature and humidity : -10℃~40℃; below 80%rh
    • Storage temperature and humidity : -20℃~60℃; below 70%rh
    • Insulation Resistance : Above 20MΩ (500V between circuit and case)
    • Pressure Resistance : AC 3700V/rms (between circuit and case)

    FEATURES

    • 4 Digit LCD Display with Black Screen
    • 9,999 Count
    • Auto Power Off (APO)
    • Conductor Size: 55mm x 32mm
    • Data Logging System 300 groups memory
    • Measure 2 times / sec
    • Double Insulation Protection Level
    • Spare 1 & 10 Test Ring, to detect Self Precision
    • POWER: AA 1.5V X 4
    • Standard Accessories :Hard Carrying Case, Test Loop, Manual
    • Dimension :285(H) x 85(W) x 58(D)mm
    Read more
  • METRAVI ERT-1501 Digital Earth Resistance Tester With Kit

    SPECIFICATIONS

    • Range : 0Ω to1000Ω
    • Resolution :
    • Accuracy : ±3%
    • DC Voltage Range : 0 V to 1000 V
    • AC Voltage Range : 0 V to 750 V
    • Resistance Range :
    • Certifications :

    FEATURES

    • Data Hold facility
    • Displays test result and battery voltage on the same screen
    • LOCK Button for continuous HANDS FREE measurement
    • Both Earth Resistance and Earth Resistivity can be measured
    • Can be used in 4 Terminal and 3 Terminal configurations
    • Display : 4 Digits EXTRA LARGE Backlit Dual LCD Display
    • Earth Resistance Range : 0 – 10/100/1000 Ohms
    • Complies with CE, CAT-III 1000V
    • Complete with Testing Kit
    • Re-Chargeable Battery and Battery Charger can be provided at extra cost
    Read more
  • METRAVI ERT-1502 Digital Earth Resistance Tester With Kit

    SPECIFICATIONS

    • Range : 0-20/200/2000 Ω
    • Resolution :
    • Accuracy : ± 2%
    • DC Voltage Range : 0 V to 1000 V
    • AC Voltage Range : 0 V to 750 V
    • Resistance Range :
    • Certifications :

    FEATURES 

    • Data Hold facility
    • Displays test result and battery voltage on the same screen
    • LOCK Button for continuous HANDS FREE measurement
    • Both Earth Resistance and Earth Resistivity can be measured
    • Can be used in 4 Terminal and 3 Terminal configurations
    • 4 Digits EXTRA LARGE Backlit Dual LCD Display
    Read more
  • MOTWANE DET-20

    SPECIFICATIONS

    • Earth Resistance Ranges :
      0.01Ωto 19.99Ω
      0.1Ωto 199.9Ω
      1Ωto 1999Ω
    • Test Frequency : 128Hz ±0.5Hz
    • Test Current :
      20 Ω Range: 10mA AC RMS
      200 Ω Range: 1mA AC RMS
      2000 Ω Range: 100µA AC RMS
      Test current is generally constant throughout the range
    • Temperature Range
      Operating : 0̊C to +55̊C <90% RH
      Storage : -20̊C to +70̊C <90% RH
    • Humidity
      Operating : 95% RH non condensing max at 40 ̊C
      Storage : 93% RH non condensing max at 55 ̊C
    • Dimensions : 180(H) x 100 (W) x54 (D) mm
    • Weight : 550gms without accessories

    FEATURES

    • 3 ½ digits LCD display with a maximum reading of up to 1999
    • 3 terminal and 4 terminal measurement method
    • Earth resistance range from 0.01Ω to 1999Ω
    • 4 soil resistivity measurement
    • Rechargeable internal Ni-MH battery
    • Earth measurement voltage of up to 200V
    • Ratiometric synchronous rectification
    Read more
  • Rishabh AET 23 Smart Digital Earth Tester

    SPECIFICATIONS 

    • Earth Resistance Ranges :
      Range : 0-20 Ohms
      Accuracy : ± (2%+10)

      Range : 0-200 Ohms
      Accuracy : ± (2%+3)

      Range : 0-2000 Ohms
      Accuracy : ± (2%+3)

    • AC Earth Voltage :
      Range : 0-200 V
      Accuracy : ± (1%+4)
    • Display Count : 2000
    •  Operating Temperature : 5° to 40°C
    •  Storage Temperature : 20 °C – 60 °C
    • Relative Humidity : 80% RH(no fog)
    • Altitude Level : 2000 Meters
    • Power : 1.5V Alkaline Batteries (LR6) x 6
    • Dimensions : 160mm x 100mm x 70.5mm
    • LCD Size : 70.6 mm x 34 mm
    • Net Weight : 560 g

    FEATURES 

    • Measurements of earth resistance across three ranges: 0-20 Ohms, 0-200 Ohms and 0-2000 Ohms
    • Measures AC earth voltage from 0-200V
    • 2000 count large-size LCD display with integrated backlight
    • Rotary dial testing selection and clearly labeled ports for V, E, P and C connections
    • Automatically powers off after ten minutes of inactivity
    • Low battery indicator
    • Data hold function
    • Memory storage up to 20 records
    • 2-wire and 3-wire testing procedures possible
    Read more
  • WACO Digital Earth Resistance Tester

    SPECIFICATIONS

    • Display : : 3½ Digits, LCD
    • Insulation Resistance Test : More than 25 Megohms at 500 V DC between electrical circuit & containing case
    • Dual Range : (a) 0 – 10 – 1000 OHM (b) 0 – 5 – 500 OHM

    FEATURES

    • Rugged ABS body
    • Easy to use hand held meter
    • Ni-cd Re- chargeable Cells
    • Confirms to ISS : 9223/1979
    • Four terminals {To measure earth resistance as well as specific
      soil resistivity}
    • Lo-Battery indication appears on Display indicating that the indicating the the cells (batteries) have gone down, which can be recharged by connecting to 230V, 50 Hz AC mains supply through charging cord provided with the instrument
    Read more