Showing all 15 results

  • RISH Clamp ES1000/400 AC Measure Control Record Analyze 3 ¾ Digits digital clamp meter

    SPECIFICATIONS

    • DC Voltage Range :
      Es-1000A Ac : 400 mV-1000 V
      Es-400A Ac : 400 mV-1000 V
      Accuracy : ±(0.5 % + 2 Digits)
    • AC Current Range :
      Es-1000A Ac : 0-1000 A
      Es-400A Ac : 0-400 A
      Accuracy: ±(1.5 % + 5 Digits)
    • AC Current Resolution :
      Es-1000A Ac : 100 mA / 1 A
      Es-400A Ac : 10 mA / 100 mA
    •  AC Voltage Range:
      Es-1000A Ac : 400 mV-1000 V
      Es-400A Ac : 400 mV-1000 V
      Accuracy: ±(1.0 % + 10 Digits)
    •  Resistance Accuracy: ±(2.0 % + 5 Digits)
    •  Capacitance Range: 5 nF-200 µF
      Accuracy: ±(5.0 % + 10 Digits)
    •  Frequency: 0-500 KHz
      Accuracy: ±(0.2 % + 2 Digits)
    • Temperature Range : 0° to 1300°C
      Accuracy : ±(2.0 % + 3 Digits)
    • Operating temperature :  -10 to +50°C
    • Storage temperature : -25 to +70°C
    • Relative humidity : 45…75% non condensing
    • Terminal Protection IP 52 for Housing and IP20 for terminals
    • Battery Voltage : 1.5 x 2 V AAA size batteries
    • Dimensions : 90mm (W) x 270mm (L) x 70mm (H)
    • Jaw Size : RISH Clamp ES1000 AC Jaw opening of 51mm for standard wire diameter of 50mm and for RISH Clamp ES400 AC Jaw
      opening of 41mm for standard wire diameter of 40mm for 400A
    • Weight : 0.6 Kg
    • Safety : IEC 61010-1-2010
    • IP for water & dust : IEC60529

    FEATURES

    • Large Jaw Opening : For RISH Clamp ES1000 AC Jaw opening of 51mm for standard wire diameter of 50mm and for RISH Clamp ES400 AC Jaw
      opening of 41mm for standard wire diameter of 40mm for 400A
    • Narrow Body : Narrow housing for firm grip and easy to carry.
    • High Accuracy for low current measurement : The clamp meter can measure accurately at not only the High currents but also Low current ranges.
    • User selectable Backlit : It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit.
    • Temperature measurement : Temperature from 0 to 1300 °C using K type thermocouple sensors.
    • AUTO POWER OFF : In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 15 minutes
    • Relative Measurement : By pressing REL key, the zero correction is made and relativevalue is measured. All functions can measure Relative value
      except Hz/Duty
    • Hold Function : By pressing HOLD key reading on the display can be latched. Simultaneously HOLD is displayed on display.
    • Hz / Duty : The instrument can measure frequency (Hz) and Duty cycle (%) of AC voltage by pressing yellow key in VAC function.
    • NULL ZERO Correction for Resistance : For Low ohm measurement, the lead resistance can be compensated by pressing REL key
    • Non contact voltage (NCV) detection : Presence of AC voltage >75 V AC 50/60 Hz can be detected by keeping jaws near voltage carrying conductor.
    • AUTO and MANUAL ranging modes : In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
    • Diode and continuity testing : For testing diode and transistors, diode measurement function is available. Continuity test generates beep sound if resistance is less than 75 ohm
    Read more
  • RISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature

    SPECIFICATIONS

    • DC Voltage Range :
      1000A Ac/Dc : 30 mV-1000 V
      300A Ac/Dc : 30 mV-1000 V
      Accuracy : ±(0.3 % + 1 Digits)
    • DC Current Range :
      1000A Ac/Dc :  0-1000 A
      300A Ac/Dc :  0-300 A
      Accuracy: ±(1.5 % + 5 Digits)
    • AC Current Range :
      1000A Ac/Dc : 0-1000 A
      300A Ac/Dc : 0-300 A
      Accuracy: ±(1.5 % + 5 Digits)
    • AC Current Resolution :
      1000A Ac/Dc : 0.1 A / 1 A
      300A Ac/Dc : 0.1 A / 1 A
    •  AC Voltage Range:
      1000A Ac/Dc : 0-1000 V
      300A Ac/Dc : 0-1000 V
      Accuracy: ±(0.75 % + 1 Digits)
    •  Resistance Accuracy: ±(0.25 % + 1 Digits)
    •  Capacitance Range: 30 nF-30 µF
    •   Accuracy: ±(3.0 % + 3 Digits)
    •  Frequency: 0-100 kHz
      Accuracy: ±(0.5 % + 1 Digits)
    • Temperature Range :  -200° to 800°C
      Accuracy : ±(1.0 % + 1)
    • Battery Voltage : 9 V DC
    • Operating temperature : -10 to +55°C
    • Storage temperature : -20 to +70°C
    • Relative humidity : 0… 90% non condensing
    • Number of digits : 3 ¾ digits.
    • Maximum count : 3100 counts
    • Weight : 0.6 Kg

    FEATURES

    • Large Jaw Opening : For RISH CLAMP 1000A AC-DC Jaw opening of 51mm for standard wire diameter of 50mm and for RISH CLAMP 300A AC-DC Jaw
      opening of 41mm for standard wire diameter of 40mm for 300A
    • Narrow Body : Narrow housing for firm grip and easy to carry.
    • High Accuracy for low current measurement : The clamp meter can measure accurately at not only the High currents but also Low current ranges.
    • User selectable Backlit : It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit.
    • Temperature measurement : Temperatures from -200 to 800 °C using Pt 100 and Pt 1000 sensors.
    • AUTO POWER OFF : In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 15 minutes
    • Analog Scale : Analog scale that updates at the rate 20 times/sec to observe fluctuations in input.
    • CONTINOUS ON MODE : In this mode, AUTO POWER OFF is disabled.
    • DATA Hold Function : By pressing DATA HOLD button, reading on the display can belatched for Hands free operation.
    • MIN,MAX Function : By pressing MIN/MAX button, the clamp meter will start recordinglatest Minimum and Maximum readings
    • NULL ZERO Correction for Resistance : For Low ohm measurement, the lead resistance can be compensated by pressing the shift key (Yellow Key)
    • NULL ZERO Correction for Capacitance : Null zero connection for capacitance. For nF range, stray capacitance can be compensated by shift key (Yellow Key)
    • AUTO and MANUAL ranging modes In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
    • Diode Measurement : For testing diode and transistors, diode measurement function is available.
    Read more
  • Rish Insu-10 Analog – Digital Insulation and Continuity Tester

    SPECIFICATIONS

    • Temperature Coefficient : <0.1% per °C
    • Operating Temperature :  -20°C To +40°C (full range)  -20°C To +60°C (upto 100M )
    • Storage Temperature :  -25°C To +65°C
    • Relative Humidity : 90% RH at 40°C max.
    • Display : LCD display Field  (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functions
    • Dimensions :  84 mm x 195 mm x 35 mm
    • Weight : 500 g including battery

    FEATURES

    •  Test Voltages 50V/ 100V/ 250V,/500V /1000V : Test voltages from 50V to 1000V can be selected for Insulation Resistance measurement .It covers all insulation tests up to 1000V
    •  Insulation Resistance measurement: The instrument is capable of measuring insulation resistance from 10 K …999 M Ohm
    •  Hands-free continuity testing: Continuity testing (0-10 W with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
    •  Voltmeter: Instrument measures voltages >25V …600V AC/DC
    •  Automatic discharge for capacitive circuits after test measurement: Capacitive devices under test, such as cables and windings, that get charged during the test, are discharged by the tester.
    •  Live circuit detection: Displays presence of voltages  25V irrespective of function selected.
    •  Pre-selectable limit checks (Go / No-Go option) for MW/GW An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
    •  Lead resistance null facility: The instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances.
    •  Storage of MIN / MAX values In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored
    •  Storage Memory for last 10 readings. The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, Continuity and Resistance measurement.
    •  Blown fuse indication. The display FUSE points to a blown fuse.
    •  Low battery indication. Automatic display of the Symbol “ ” when battery cells are exhausted.
    •  Stop Watch. : This function allows you to measure elapsed time up to 1 hour.
    •  Auto-power off function : The instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation.
    •  Protective holster for rough duty . A holster of soft rubber with tilt stand protects the meter against damage in the case of shock and drop
    Read more
  • Rish Insu-20 Analog – Digital Insulation and Continuity Tester

    SPECIFICATIONS 

    • Temperature Coefficient : <0.1% per °C
    • Operating Temperature :  -20°C To +40°C (full range)  -20°C To +60°C (upto 100M )
    • Storage Temperature :  -25°C To +65°C
    • Relative Humidity : 90% RH at 40°C max.
    • Display : LCD display Field  (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functions
    • Dimensions :  84 mm x 195 mm x 35 mm
      • Weight : 500 g including battery

    FEATURES 

    • Analog + Digital Display ( Log scale for Insulation Measurement) : The Analog scale for insulation resistance measurement is Logarithmic in nature which gives the dynamic performance of an Analog insulation tester. The Analog scale is linear for low Ohm and Voltage measurement.
    •  User Selectable Backlit Display: The instrument is provided with user selectable Back lit for taking measurements in dark areas/poor lighting conditions.
    •  Connector jack for External Mains Adapter (Optional) : The instrument can be operated from Mains Supply(230VAC) instead of Batteries using an external Mains Adapter (230VAC /9VDC,500mA (4.5VA) Isolated)
    •  Test Voltages 50V/ 100V/ 250V,/500V /1000V : Test voltages from 50V to 1000V can be selected for Insulation Resistance measurement .It covers all insulation tests up to 1000V
    •  Insulation Resistance measurement: The instrument is capable of measuring insulation resistance from 10 kW…2 GW
    •  Low Resistances measurement: 0.01 W … 99.9 W Low resistances can be measured up to 99.9 W. There are two measuring ranges for Low W.: 9.99W and 99.9W
    •  Hands-free continuity testing: Continuity testing (0-10 W with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
    •  Voltmeter: Instrument measures voltages >25V …600V AC/DC
    •  Automatic discharge for capacitive circuits after test measurement: Capacitive devices under test, such as cables and windings, that get charged during the test, are discharged by the tester.
    •  Live circuit detection: Displays presence of voltages  25V irrespective of function selected.
    •  Pre-selectable limit checks (Go / No-Go option) for MW/GW An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
    •  Lead resistance null facility: The instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances.
    •  Storage of MIN / MAX values In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored
    •  Storage Memory for last 10 readings. The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, Continuity and Resistance measurement.
    •  Blown fuse indication. The display FUSE points to a blown fuse.
    •  Low battery indication. Automatic display of the Symbol “ ” when battery cells are exhausted.
    •  Stop Watch. : This function allows you to measure elapsed time up to 1 hour.
    •  Auto-power off function : The instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation.
    •  Protective holster for rough duty . A holster of soft rubber with tilt stand protects the meter against damage in the case of shock and drop
    Read more
  • Rishabh 616 Digital Multimeter- True Rms

    SPECIFICATIONS

    • DC Voltage : 100µV-1000V
    • DC Current : 10µA-10.00A
    • Resistance: 100mΩ… 60.00MΩ
    • Capacitance : 1pF – 40 mF with zero correction
    • Frequencies :  10.00Hz – 10MHz
    •  Operating Temperature : 0° to 50°C
    •  Storage Temperature : -25 °C – 70 °C
    • Dimensions With Holster : 86 x 188 x 53 mm
    • Dimensions Without Holster : 79 x 174 x 38mm
    • Weight : Approx 0.480g with battery .

    FEATURES

    • Root mean square value with distorted wave form.
    • Dual Display
    • Peak Hold
    • MIN/MAX Function
    • Temperature Measurement
    • Indication of negative values on the analog scale
    • Analog Scale
    • Protection from dust and water Instrument: IP 52
      For terminals : IP20 as per IEC60529.
    • Applicable International Safety standards 1000 V CAT III/600V CAT IV as per International Safety standard IEC 61010-1- 2010 and IEC 61557
    • Hold
    • Relative measurement (REL)
    • Automatic terminal blocking system(ABS)
    • Auto and Manual ranging modes
    • Hz/Duty
    • Diode and continuity testing
    • Continuous ON mode
    Read more
  • Rishabh AET 23 Smart Digital Earth Tester

    SPECIFICATIONS 

    • Earth Resistance Ranges :
      Range : 0-20 Ohms
      Accuracy : ± (2%+10)

      Range : 0-200 Ohms
      Accuracy : ± (2%+3)

      Range : 0-2000 Ohms
      Accuracy : ± (2%+3)

    • AC Earth Voltage :
      Range : 0-200 V
      Accuracy : ± (1%+4)
    • Display Count : 2000
    •  Operating Temperature : 5° to 40°C
    •  Storage Temperature : 20 °C – 60 °C
    • Relative Humidity : 80% RH(no fog)
    • Altitude Level : 2000 Meters
    • Power : 1.5V Alkaline Batteries (LR6) x 6
    • Dimensions : 160mm x 100mm x 70.5mm
    • LCD Size : 70.6 mm x 34 mm
    • Net Weight : 560 g

    FEATURES 

    • Measurements of earth resistance across three ranges: 0-20 Ohms, 0-200 Ohms and 0-2000 Ohms
    • Measures AC earth voltage from 0-200V
    • 2000 count large-size LCD display with integrated backlight
    • Rotary dial testing selection and clearly labeled ports for V, E, P and C connections
    • Automatically powers off after ten minutes of inactivity
    • Low battery indicator
    • Data hold function
    • Memory storage up to 20 records
    • 2-wire and 3-wire testing procedures possible
    Read more
  • Rishabh AIT 501 Smart 5KV Digital Insulation Tester

    SPECIFICATIONS

    • Test Voltages : 500V, 1000V, 2500V, 5000V
    • Test Voltage Accuracy : 0% to 20%
    • 500V Range (Accuracy) : 1MOhm to 20GOhm (± 3%+5)
    • 1000V Range (Accuracy) : 2MOhm to 40GOhm (± 3%+5)
    • 2500V Range (Accuracy) : 5MOhm to 100GOhm (± 3%+5)
    • 5000V Range (Accuracy) : 10MOhm to 1000GOhm (± 3%+5)
    • Short Circuit Current : 1.8 mA
    • AC/ DC Voltage : 600V
    • Low Resistance : 0.1Ohm to 999.9Ohm
    • Operating Temperature : -10 to 40 °C
    • Storage Temperature : -20 to 60° C
    • Relative humidity : 85% @ -10 °C to 40 °C
    • Dimensions  : 202 x 155 x 94 mm
    • LCD Size  : 123mm x 58mm
    • Net Weight: Approx. 2kg (including battery)

    FEATURES

    • Robust unit
    • Test voltages of 500V, 1000V, 2500V and 5000V & Insulation Resistance measurement upto 1 T Ohm
    • Automatic Polarisation Index (PI), Dielectric Absorption Ratio (DAR)
    • DC/AC voltage measurements to 600V
    • Autoranging insulation resistance tester
    • Auto shut down when left idle & Optional Operation on Mains via adapter
    • Datalogging capabilities and USB interface
    • Comparator Function
    • Wide LCD with backlit screen, Analog bar graph (30 segment)
    Read more
  • Rishabh ALCT 606A Smart Leakage Clamp Meter

    SPECIFICATIONS 

    • Leakage Current
      Range : 0〜60.00A
      Accuracy : ±(1.5%+5)

      Range : 60.00A〜199.9A
      Accuracy : ±(2%+5)

      Range : 200.0A〜300.0A
      Accuracy : ±(3%+5)

      Range : 300.0A〜600.0A
      Accuracy : ±(4%+5)

    • Resolution : 0.1 mA
    • Display mode : 4 Digits LCD Display
    • Clamp Size : 35mm×40mm
    • Auto Power Off : 5 Minutes
    • Operating Temperature : -10 to 40 °C
    • Storage Temperature : -20 to 60° C
    • Relative humidity : 80% @ -10 °C to 40 °C
      Below 70% @ -20 °C to 60°C
    • Dimensions : 175mm X 70mm X 38mm
    • LCD Dimension : 32mm X 15mm’
    • Weight : 120g

    FEATURES

    •  Compact size leakage clamp meter
    •  Current measurement from 0.1mA to 600A
    •  Large jaw opening
    •  Data storage facility upto 99 records
    • Complies with CE, CAT protection
    •  Software facility for reports
    Read more
  • Rishabh ALCT 60A AC/DC Smart Leakage Clamp Meter

    SPECIFICATIONS

    • Current (A) : 0 mA~60.0A AC/DC
    • Accuracy : ±(2%+5)
    • Resolution : 1 mA AC/DC
    • Frequency Response AC : 45Hz ~200Hz
    • Display Mode : 4-bit LCD display 10,000 count
    • Jaw Size : 7mm
    • Line Voltage :  not beyond 600 V
    • Auto Power Off : 5 mins
    • Low Battery Indication : Indicates low battery when the voltage is 7.2V
    • Sampling Rate : About 2 sec per time
    • Working Current : 20 mA
    • Dimensions : 168mm x 65mm x 34 mm
    • Weight : 180g (with batteries )

    FEATURES 

    • Compact size leakage clamp meter for easy portability
    • Current measurement from 1mA to 60A AC/DC
    • Data storage facility upto 99 records
    •  Software facility for online reports generation
    • l Complies with CE, CAT protection
    Read more
  • Rishabh ALCT 66A Smart Leakage Clamp Meter

    SPECIFICATIONS

    • Leakage Current (A) :
      Range : 0.001mA to 60.00A
      Resolution : 1uA
      Accuracy : ±(1.5%+5)
    • Display Mode : 4 Digits LCD Display
    • Jaw Capacity : 25 mm × 30 mm
    • Data Storage : 99
    • Operating Temperature : -10 to 40 °C
    • Storage Temperature : -20 to 60° C
    • Relative humidity : 80% @ -10 °C to 40 °C
      Below 70% : @ -20 °C to 60°C
    • Test Mode : Clamp CT, Integral Approach

    FEATURES : 

    •  Compact size leakage clamp meter
    •  Current measurement from 1µA to 60A
    •  Large jaw opening
    •  Data storage facility upto 99 records
    •  Complies with CE, CAT protection
    •  Software facility for reports
    Read more
  • Rishabh Instruments Rish Multi 13S 1000V Digital Multimeter

    SPECIFICATIONS

    • Display : 3¾ digit
    •  Counts : 3100
    •  AC Voltage Range : 1mV to 1000V
    •  DC Voltage Range : 10µV-1000V
    •  AC Current Range : 10µA- 16 A
    •  DC Current Range (Amp) : 1µA-16mA
    • Sampling Rate : 2 Readings/Second
    •  Operating Temperature : -10 C -50 C
    •  Storage Temperature : -25 C – 70 C
    •  Altitude : 2000 m
    •  Power Input : 9V
    •  Dimensions : 84x195x35 mm
    •  Weight (g) : Approx. 0.35 Kg with battery

    FEATURES

    • Automatic Terminal Blocking System (ABS)
    • Interface and Software RISH com 100
    • MIN/MAX Value Storage
    • Indication Of Negative Values On The Analog Scale
    • Indication Of Negative Values On The Analog Scale
    • Automatic Data Hold*
    • Auto-ranging / Manual Range Selection
    • Continuity Test
    • Temperature Measurement
    • Signaling in the case of a blown fuse
    • Power economizing circuit
    • Overload Warning
    • Protective holster for rough duty
    Read more
  • Rishabh multi 12S Digital Multimeter (AC Volt 1mV to 1000V)

    SPECIFICATIONS

    • Display : 3¾ digit
    •  Counts : 3100
    •  AC Voltage Range : 1mV to 1000V
    •  DC Voltage Range : 10µV-1000V
    •  AC Current Range : 10µA-300A
    •  DC Current Range (Amp) : 1µA-300mA
    • Sampling Rate : 2 Readings/Second
    •  Operating Temperature : -10 C -50 C
    •  Storage Temperature : -25 C – 70 C
    •  Altitude : 2000 m
    •  Power Input : 9V
    •  Dimensions : 84x195x35 mm
    •  Weight (g) : Approx. 0.35 Kg with battery

    FEATURES

    • Automatic Terminal Blocking System (ABS)
    • Interface and Software RISH com 100
    • MIN/MAX Value Storage
    • Indication Of Negative Values On The Analog Scale
    • Indication Of Negative Values On The Analog Scale
    • Automatic Data Hold*
    • Auto-ranging / Manual Range Selection
    • Continuity Test
    • Temperature Measurement
    • Signaling in the case of a blown fuse
    • Power economizing circuit
    • Overload Warning
    • Protective holster for rough duty
    Read more
  • Rishabh Rish 14S Digital Multimeter

    SPECIFICATIONS

    • Display : 3¾ digit
    •  Counts : 3100
    •  AC Voltage Range : 0 to 1000V
      Accuracy : ±0.75 +2
    •  DC Voltage Range : 30mV-1000V
      Accuracy : ±0.35 +1
    •  AC Current Range : 300µA- 10 A
    •  DC Current Range (Amp) : 300µA- 10 A
    • Sampling Rate : 2 Readings/Second
    •  Operating Temperature : -10° to 50°C
    •  Storage Temperature : -25 °C – 70 °C
    •  Altitude : 2000 m
    •  Power Input : 9V
    •  Dimensions : 84x195x35 mm
    •  Weight (g) : Approx. 0.35 Kg with battery

    FEATURES

    • Automatic Terminal Blocking System (ABS)
    • Interface and Software RISH com 100
    • MIN/MAX Value Storage
    • Indication Of Negative Values On The Analog Scale
    • Indication Of Negative Values On The Analog Scale
    • Automatic Data Hold*
    • Auto-ranging / Manual Range Selection
    • Continuity Test
    • Temperature Measurement
    • Signaling in the case of a blown fuse
    • Power economizing circuit
    • Overload Warning
    • Protective holster for rough duty
    • Protection IP50
    Read more
  • Rishabh RISH Multi 15S Digital Multimeter

    SPECIFICATIONS

    • Display : 3¾ digit
    •  Counts : 3100
    •  AC Voltage Range : 1mV to 1000V
    •  DC Voltage Range : 10µV-1000V
    •  AC Current Range : 1µA-10A
    •  DC Current Range (Amp) : 100nA-10A
    • Capacitance Range : 10pF – 30µF
    • Frequency Range : 0.1 Hz – 100 KHz
    • Sampling Rate : 2 Readings/Second
    •  Operating Temperature : -10° to 50°C
    •  Storage Temperature : -25 °C – 70 °C
    •  Altitude : 2000 m
    •  Power Input : 9V
    •  Dimensions : 84x195x35 mm
    •  Weight (g) : Approx. 0.35 Kg with battery

    FEATURES

    • Automatic Terminal Blocking System (ABS)
    • Interface and Software RISH com 100
    • MIN/MAX Value Storage
    • Indication Of Negative Values On The Analog Scale
    • Indication Of Negative Values On The Analog Scale
    • Automatic Data Hold*
    • Auto-ranging / Manual Range Selection
    • Continuity Test
    • Temperature Measurement
    • Signaling in the case of a blown fuse
    • Power economizing circuit
    • Overload Warning
    • Protective holster for rough duty
    • Protection IP50
    Read more
  • Rishabh RISH Multi 16S Digital Multimeter

    SPECIFICATIONS

    • Display : 3¾ digit
    •  Counts : 3100
    •  AC Voltage Range : 1mV to 1000V
    •  DC Voltage Range : 10µV-1000V
    •  AC Current Range : 1µA-10A
    •  DC Current Range (Amp) : 100nA-10A
    • Capacitance Range : 10pF – 30µF
    • Frequency Range : 0.1 Hz – 100 KHz
    • Sampling Rate : 2 Readings/Second
    •  Operating Temperature : -10° to 50°C
    •  Storage Temperature : -25 °C – 70 °C
    •  Altitude : 2000 m
    •  Power Input : 9V
    •  Dimensions : 84x195x35 mm
    •  Weight (g) : Approx. 0.35 Kg with battery

    FEATURES

    • Automatic Terminal Blocking System (ABS)
    • Interface and Software RISH com 100
    • MIN/MAX Value Storage
    • Indication Of Negative Values On The Analog Scale
    • Indication Of Negative Values On The Analog Scale
    • Automatic Data Hold*
    • Auto-ranging / Manual Range Selection
    • Continuity Test
    • Temperature Measurement
    • Signaling in the case of a blown fuse
    • Power economizing circuit
    • Overload Warning
    • Protective holster for rough duty
    • Protection IP50
    Read more