| Description | SPECIFICATIONS
- AC Current via Jaw
Range : 999.9A
Resolution : 0.1A
Accuracy : 2% ± 5 digits (10-100 Hz) ; 2.5% ± 5 digits (100-500 Hz)
- AC Current via Flexible Current Probe
Range : 2500A
Resolution : 0.1 A (≤ 999.9 A) ; 1 A (≤ 2500 A)
Accuracy : 3% ±5 digits (5 – 500 Hz)
- DC Current
Range : 999.9A
Resolution : 0.1 A
Accuracy : 2% ±5 digits
- AC Voltage
Range : 1000V
Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
Accuracy : 1.5% ± 5 digits (20 – 500 Hz)
- DC Voltage
Range : 1000V
Resolution : 0.1 V (≤ 600.0 V) ; 1 V (≤ 1000 V)
Accuracy : 1% ±5 digits
- Frequency Via Jaw
Range : 5.0 - 500.0 Hz
Resolution : 0.1 Hz
Accuracy : 0.5% ± 5 digits
- Frequency via Flexible Current Probe
Range : 5.0 - 500.0 Hz
Resolution : 0.1 Hz
Accuracy : 0.5% ± 5 digits
- Resistance
Range : 60 kΩ
Resolution : 0.1 Ω (≤ 600 Ω) ; 1 Ω (≤ 6000 Ω) ; 10 Ω (≤ 60 kΩ)
Accuracy : 1% ± 5 digits
- Capacitance
Range : 1000 μF
Resolution : 0.1 μF (≤ 100 μF) ; 1 μ F (≤ 1000 μF)
Accuracy : 1% ± 4 digits
- Jaw Opening : 34mm
- Flexible Current Probe Diameter : 7.5mm
- Flexible Current Probe Cable Length (head to electronics connector) : 1.8M
- Operating Temperature : 14°F to 122°F (-10 °C to 50 °C)
- Storage Temperature : -40 °F to 140 °F (-40 °C to 60 °C)
- Size : 246 mm x 83 m x 43 mm
- Weight : 388g
FEATURES
- iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
- CAT IV 600 V, CAT III 1000 V
- True RMS AC voltage and current for accurate measurements on non-linear signals
- Min, max, average and Inrush recording to capture variations automatically
- Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary Inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Three-year warranty
- Soft Carrying Case
| SPECIFICATIONS :
- DC VOLTAGE : 1000V
- AC VOLTAGE : 750V
- AC CURRENT : 300A
- RESISTANCE : 60M ohms
- FREQUENCY : 50⁓1KHz
- TEMPERATURE : -40~2000℉
- CAPACITANCE : 60nF/600nF/6µF/60µF/400µ/20mF
FEATURES :
- TRANSFORMER JAWS
- TRIGGER
- RANGE BUTTONS
- Hz/DUTY BUTTON
- "COM" TERMINAL
- DATA HOLD /BCKLIGHT BUTTON
- INPUT TERMINAL
- FUNCTION SWITCH/RANGE SWITCH
- SELECT BUTTON
| SPECIFICATION
- AC current : 1000A
- AC Voltage : 750V
- DC Voltage : 1000V
- Resistance : 20KΩ
- Insulation test : 2000MΩ
- Audible continuity : Overload Protection 15s maximum 250Vrms
FEATURES
- Display Mode: 3 1/2 LCD
- Maximum Display: 1999, 0.5” high
- Maximum Span of Jaw: 53mm
- Auto Polarity Indication: Displaying “-”, assumed “+”
- Sampling speed: 2 times/s
- Over-load indication: “1” is displayed
- Low battery indication
- Power supply: 9V
- Dimensions: 230 x 68 x 37mm
- Weight: ≈ 240g (battery included)
- Static electricity: ≈ 4mA
- Operating environment: 0˚C ~ 40˚C, at <80% RH
- Storage environment: -10 ˚C ~ 50˚C at <85% RH
| SPECIFICATIONS :
- DC VOLTAGE : 200mV, 2V, 20V, 200V, 1000V
- AC VOLTAGE : 2V, 20V, 200V, 750V
- AC CURRENT : 2A, 20A, 200A, 1000A
- TEMPERATURE : -20 to 750 deg C
- JAW OPENING : 52mm (max.)
- RESISTANCE : 200Ω, 2kΩ, 20ΩK, 200kΩ, 2MΩ, 20MΩ
FEATURES :
- Auto/Manual Ranging.
- Temperature, Data Hold.
- Max, NCV, APO.
| SPECIFICATION
- DC VOLTAGE: 1000V
- AC VOLTAGE: 750V
- AC CURRENT: 1000A
- DC CURRENT: 1000A
- RESISTANCE: 200OHMS to 20 MEGA OHMS
- CAPACITANCE: 400uF to 40uF
FEATURES:
- 3½ Digit Clamp Meter with Backlight
- 2000 Count
- Clamp Torch
- Jaw Open : 52 mm
- Auto Power Off (APO)
- True RMS
- POWER : 9V (6F22) X 1
- Standard Accessories : Soft Carrying Case, Manual, Test Lead
- Dimension : 270(H) x 123(W) x 35(D) mm
| SPECIFICATIONS :
- DC CURRENT : 600A
- AC CURRENT : 600A
- AC VOLTAGE : 600V
- DC VOLTAGE : 600V
- DISPLAY : 3 5/6 digit,6000
- BETTERY : 9V (6F22)
- TEMPERATURE : 600°C
- CAPACITANCE : 1000uF
- FREQUENCY : 10 MHz
-
RESISTANCE : 60MΩ
FEATURES:
- Op. Current <2mA (no back light).
- LCD Display,
- Auto / Manual Ranging, Data Hold.
- NCV APO, Temperature, Frequency, Max Hold.
- Diode Test, Resistance, Duty Cycle.
- Continuity Buzzer, Backlight, Trms.
- Low Battery Indicated.
- Duty Cycle : 0.1% - 99.9%.
|
| Content | You can measure around awkward sized conductors with the Fluke 376 True RMS Clamp Meter with iFlex®, expanding your measurement range to 2500 A AC. With True RMS voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both AC and DC modes.
The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter. | | BEETECH M266 Digital AC Clamp Meter is a versatile and easy-to-use clamp meter that can measure AC current, AC/DC voltage, resistance, and continuity. It is perfect for use in a variety of applications, including electrical maintenance, HVAC/R, automotive, and more. The clamp meter is a precision instrument that is perfect for a wide range of applications. It is affordably priced and has exceptional quality. This clamp meter is easy to use and has a wide variety of features that make it perfect for any measuring need. | Meco 2502T-AUTO AC Digital Clamp Meter is a great product for those who are looking for a reliable and accurate clamp meter. It is easy to use and has a large LCD display that makes it easy to read. The Meco clamp meter is best for those looking for a reasonably priced, long lasting measurement and testing device. This product is known for its quality and durability, making it a great choice for anyone in the market for a reliable clamp meter. | The HTC CM-2046 is a reliable and easy-to-use clamp meter that is perfect for a variety of applications. This clamp meter features a large LCD display for easy reading, a built-in LED light for illumination in dark areas, and a durable design that is built to last. The HTC Clamp Meter is a reliable and accurate device that is perfect for measuring DC and AC voltage, AC current, and resistance. With a DC voltage accuracy of 0.5% and an AC voltage accuracy of 1.0%, this meter is perfect for use in any situation where precise measurements are required. Additionally, the AC current range of 200A/1000A and the AC current accuracy of 2.0% make this meter perfect for measuring large currents. Finally, the resistance accuracy of 0.8% ensures that this meter is perfect for measuring resistance in any circuit. | MECO-G TRMS Clamp Meter, R-2070D is a premium quality product from MECO-G. All MECO-G TRMS Clamp Meter, R-2070D are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G TRMS Clamp Meter, R-2070D, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Clamp Meters . |