SPECIFICATIONS 

  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS
    Accuracy : 45 Hz – 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A)
    Accuracy : 15 Hz – 45 Hz, 400 Hz – 2 kHz: ±2.0% rdg ±5 dgt
    Defined Accuracy Range : 0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Output Function : RMS (RMS value output), WAVE (waveform output)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
    *Harmonics can be displayed with our free app GENNECT Cross.
  • Display : Display refresh rate: 5 times/s
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2

FEATURES

  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Broad measurement range extending from leakage currents to load currents
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • Solve GFCI and RCD problems quickly
  • Speed up pass/fail judgments with the built-in comparator function
  • Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
  • External power supply: use an optional AC adapter for continuous, long-term measurement
  • CAT III 300 V

Description

CM4002 AND CM4003

Reviews

There are no reviews yet.

Be the first to review “HIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function)”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function) removeMECO 2502T AUTO BL CLAMPMETER removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeHTC CM-2046 1000A AC/DC Digital Clampmeter removeHTC CL-2054 10uA high Resolution AC Leakage Current Tester 40mA ~ 100A removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER remove
NameHIOKI CM-4003 AC LEAKAGE CLAMP METER (Output and external power supply function) removeMECO 2502T AUTO BL CLAMPMETER removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeHTC CM-2046 1000A AC/DC Digital Clampmeter removeHTC CL-2054 10uA high Resolution AC Leakage Current Tester 40mA ~ 100A removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS 
  • AC Current Range : 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Accuracy : 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Accuracy : 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt Defined Accuracy Range : 0.060 mA to 200.0 A
  • Frequency range : 15.0 Hz to 2000 Hz
  • Crest factor : 3 (other than 200.0 A range), 1.5 (200.0 A range)
  • Filter function : Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB)
  • Output Function : RMS (RMS value output), WAVE (waveform output)
  • Harmonic Levels : [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio *Harmonics can be displayed with our free app GENNECT Cross.
  • Display : Display refresh rate: 5 times/s
  • Core Jaw Diameter : φ 40 mm (1.57 in.)
  • Dimensions : 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D
  • Mass : 400 g (14.1 oz.)
  • Included Accessories : Connection Cable L9097 × 1, USB Cable × 1, Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2
FEATURES
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
  • Broad measurement range extending from leakage currents to load currents
  • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
  • Solve GFCI and RCD problems quickly
  • Speed up pass/fail judgments with the built-in comparator function
  • Output function (waveform/RMS): use with a recorder to record waveforms and fluctuations
  • External power supply: use an optional AC adapter for continuous, long-term measurement
  • CAT III 300 V
SPECIFICATIONS :
  • DC VOLTAGE : 200mV, 2V, 20V, 200V, 1000V
  • AC VOLTAGE : 2V, 20V, 200V, 750V
  • AC CURRENT : 2A, 20A, 200A, 1000A
  • TEMPERATURE : -20 to 750 deg C
  • JAW OPENING : 52mm (max.)
  • RESISTANCE : 200Ω, 2kΩ, 20ΩK, 200kΩ, 2MΩ, 20MΩ
FEATURES : 
  • Auto/Manual Ranging.
  • Temperature, Data Hold.
  • Max, NCV, APO.
SPECIFICATIONS:
  • DC Voltage: 2000V
  • AC Voltage: 2000V
  • DC Current: 2000A
  • AC Current: 2000A
  • Resistance: 20 M ohms
  • Capacitance: 2000uF
  FEATURES
  • Display Mode: Display by LCD
  • Maximum Display: 1999
  • Digits: 3 ½ Digits
  • Maximum span of jaw: 55mm
  • Auto Range
  • Inrush Current
  • Resistance
  • Capacitance
  • Diode Test
  • Continuity Test
  • Data Hold
  • LED Testing
  • Back Light + Lamp Light
  • Auto negative polarity indication: displaying ‘-’
  • Auto Power Off
  • Battery: 9V
 
SPECIFICATION
  • DC VOLTAGE: 1000V
  • AC VOLTAGE: 750V
  • AC CURRENT: 1000A
  • DC CURRENT: 1000A
  • RESISTANCE: 200OHMS to 20 MEGA  OHMS
  • CAPACITANCE: 400uF to 40uF
FEATURES:
  • 3½ Digit Clamp Meter with Backlight
  • 2000 Count
  • Clamp Torch
  • Jaw Open : 52 mm
  • Auto Power Off (APO)
  • True RMS
  • POWER : 9V (6F22) X 1
  • Standard Accessories : Soft Carrying Case, Manual, Test Lead
  • Dimension : 270(H) x 123(W) x 35(D) mm
 Specification
  • AC Voltage: 400V
  • AC  Current: 40mA/400mA/4A/40A/80A/80-100A
  • Resistance Range: 40-400 Ohms
  • CONTINUITY TEST : Threshold 40Ω, Continuity Beeper 2.5KHz
FEATURES
  • 3¾ Digit Manual Range
  • 3,999 Count
  • 10uA high Resolution
  • Auto Power Off (APO)
  • Shielded Transformer Jaw Open to 1.2”
  • POWER: 9V (6F22) X 1
  • Standarrd Accesories :Hard Carrying Case, Test Lead, Manual
  • Dimension : 209(H) x 43(W) x 30(D)mm
SPECIFICATIONS : 
  • DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
  • AC VOLTAGE : 4V, 40V, 400V, 750V
  • RESISTANCE : 4000, 4kQ, 40KQ, 400kQ, 4MQ, 40MQ (auto ranging)
  • DIMENSIONS : 229x69x38 mm
FEATURES : 
  • 1000A AC auto ranging. 3 digit 3999 counts. Data hold, frequency, capacitance. APO ranges.
ContentCM4002 AND CM4003Meco 2502T-AUTO AC Digital Clamp Meter is a great product for those who are looking for a reliable and accurate clamp meter. It is easy to use and has a large LCD display that makes it easy to read. The Meco clamp meter is best for those looking for a reasonably priced, long lasting measurement and testing device. This product is known for its quality and durability, making it a great choice for anyone in the market for a reliable clamp meter.B-6096 is a 2000V AC/DC and 2000A AC/DC TRUE RMS Digital Clamp meter. It adopts high performance MCU processor. It is of great value as it has high reliability, accuracy, quality and automatic setting range function. The product has a large digital display, full range overload protection, data hold function, under voltage detection, auto shut off function. The TRUE RMS function can accurately measure frequency voltage, suitable for measuring motor and compressor starting current. Along with AC/DC current, AC/DC voltage it can measure resistance, capacitance, continuity test, diode forward voltage drop, LED operating voltage, and other parameters. This instrument is easy to operate and carry making it an ideal tool for electrical measurement. Especially suitable for measuring large currents and starting currents.    The HTC CM-2046 is a reliable and easy-to-use clamp meter that is perfect for a variety of applications. This clamp meter features a large LCD display for easy reading, a built-in LED light for illumination in dark areas, and a durable design that is built to last. The HTC Clamp Meter is a reliable and accurate device that is perfect for measuring DC and AC voltage, AC current, and resistance. With a DC voltage accuracy of 0.5% and an AC voltage accuracy of 1.0%, this meter is perfect for use in any situation where precise measurements are required. Additionally, the AC current range of 200A/1000A and the AC current accuracy of 2.0% make this meter perfect for measuring large currents. Finally, the resistance accuracy of 0.8% ensures that this meter is perfect for measuring resistance in any circuit.HTC CL-2054 AC Leakage Current Tester is a premium quality product from HTC. All HTC CL-2054 AC Leakage Current Tester are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture HTC CL-2054 AC Leakage Current Tester, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. HTC products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of HTC Leakage Testers .Meco Digital Clamp Meter 3150 comes with a number of interesting features such as 3 digit 3999 counts frequency data hold APO ranges and capacitance. It comes with a resistance of 4000 4kQ 40KQ 400kQ 4MQ 40MQ. Highly rated by technical experts this digital clamp meter from Meco is suitable for use in DIY projects as well as industries.
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information