RISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature

Brands:
Category:

Availability: In Stock

SPECIFICATIONS

  • DC Voltage Range :
    1000A Ac/Dc : 30 mV-1000 V
    300A Ac/Dc : 30 mV-1000 V
    Accuracy : ±(0.3 % + 1 Digits)
  • DC Current Range :
    1000A Ac/Dc :  0-1000 A
    300A Ac/Dc :  0-300 A
    Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Range :
    1000A Ac/Dc : 0-1000 A
    300A Ac/Dc : 0-300 A
    Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Resolution :
    1000A Ac/Dc : 0.1 A / 1 A
    300A Ac/Dc : 0.1 A / 1 A
  •  AC Voltage Range:
    1000A Ac/Dc : 0-1000 V
    300A Ac/Dc : 0-1000 V
    Accuracy: ±(0.75 % + 1 Digits)
  •  Resistance Accuracy: ±(0.25 % + 1 Digits)
  •  Capacitance Range: 30 nF-30 µF
  •   Accuracy: ±(3.0 % + 3 Digits)
  •  Frequency: 0-100 kHz
    Accuracy: ±(0.5 % + 1 Digits)
  • Temperature Range :  -200° to 800°C
    Accuracy : ±(1.0 % + 1)
  • Battery Voltage : 9 V DC
  • Operating temperature : -10 to +55°C
  • Storage temperature : -20 to +70°C
  • Relative humidity : 0… 90% non condensing
  • Number of digits : 3 ¾ digits.
  • Maximum count : 3100 counts
  • Weight : 0.6 Kg

FEATURES

  • Large Jaw Opening : For RISH CLAMP 1000A AC-DC Jaw opening of 51mm for standard wire diameter of 50mm and for RISH CLAMP 300A AC-DC Jaw
    opening of 41mm for standard wire diameter of 40mm for 300A
  • Narrow Body : Narrow housing for firm grip and easy to carry.
  • High Accuracy for low current measurement : The clamp meter can measure accurately at not only the High currents but also Low current ranges.
  • User selectable Backlit : It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit.
  • Temperature measurement : Temperatures from -200 to 800 °C using Pt 100 and Pt 1000 sensors.
  • AUTO POWER OFF : In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 15 minutes
  • Analog Scale : Analog scale that updates at the rate 20 times/sec to observe fluctuations in input.
  • CONTINOUS ON MODE : In this mode, AUTO POWER OFF is disabled.
  • DATA Hold Function : By pressing DATA HOLD button, reading on the display can belatched for Hands free operation.
  • MIN,MAX Function : By pressing MIN/MAX button, the clamp meter will start recordinglatest Minimum and Maximum readings
  • NULL ZERO Correction for Resistance : For Low ohm measurement, the lead resistance can be compensated by pressing the shift key (Yellow Key)
  • NULL ZERO Correction for Capacitance : Null zero connection for capacitance. For nF range, stray capacitance can be compensated by shift key (Yellow Key)
  • AUTO and MANUAL ranging modes In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
  • Diode Measurement : For testing diode and transistors, diode measurement function is available.
Category:

Description

RISH Clamp 1000A/300A measures important electrical parameters like AC Current (TRMS), DC Current, AC Voltage(TRMS), and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature measurement.

Reviews

There are no reviews yet.

Be the first to review “RISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsRISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeMECO G R-1818T DIGITAL CLAMP METER removeHTC CM 2000 - 600A AC Clamp Meter removeMECO 2502T AUTO BL CLAMPMETER removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER remove
NameRISH Clamp1000A/300A AC-DC 3 ¾ Digits TRMS 3 ¾ Digits digital Clamp meter with VFD measurement feature removeBEETECH B-6096 Solar Clampmeter 2000A AC/DC & 2000V AC/DC removeMECO G R-1818T DIGITAL CLAMP METER removeHTC CM 2000 - 600A AC Clamp Meter removeMECO 2502T AUTO BL CLAMPMETER removeMECO 3150+ 3 DIGIT DIGITAL CLAMPMETER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS
  • DC Voltage Range : 1000A Ac/Dc : 30 mV-1000 V 300A Ac/Dc : 30 mV-1000 V Accuracy : ±(0.3 % + 1 Digits)
  • DC Current Range : 1000A Ac/Dc :  0-1000 A 300A Ac/Dc :  0-300 A Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Range : 1000A Ac/Dc : 0-1000 A 300A Ac/Dc : 0-300 A Accuracy: ±(1.5 % + 5 Digits)
  • AC Current Resolution : 1000A Ac/Dc : 0.1 A / 1 A 300A Ac/Dc : 0.1 A / 1 A
  •  AC Voltage Range: 1000A Ac/Dc : 0-1000 V 300A Ac/Dc : 0-1000 V Accuracy: ±(0.75 % + 1 Digits)
  •  Resistance Accuracy: ±(0.25 % + 1 Digits)
  •  Capacitance Range: 30 nF-30 µF
  •   Accuracy: ±(3.0 % + 3 Digits)
  •  Frequency: 0-100 kHz Accuracy: ±(0.5 % + 1 Digits)
  • Temperature Range :  -200° to 800°C Accuracy : ±(1.0 % + 1)
  • Battery Voltage : 9 V DC
  • Operating temperature : -10 to +55°C
  • Storage temperature : -20 to +70°C
  • Relative humidity : 0... 90% non condensing
  • Number of digits : 3 ¾ digits.
  • Maximum count : 3100 counts
  • Weight : 0.6 Kg
FEATURES
  • Large Jaw Opening : For RISH CLAMP 1000A AC-DC Jaw opening of 51mm for standard wire diameter of 50mm and for RISH CLAMP 300A AC-DC Jaw opening of 41mm for standard wire diameter of 40mm for 300A
  • Narrow Body : Narrow housing for firm grip and easy to carry.
  • High Accuracy for low current measurement : The clamp meter can measure accurately at not only the High currents but also Low current ranges.
  • User selectable Backlit : It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit.
  • Temperature measurement : Temperatures from -200 to 800 °C using Pt 100 and Pt 1000 sensors.
  • AUTO POWER OFF : In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 15 minutes
  • Analog Scale : Analog scale that updates at the rate 20 times/sec to observe fluctuations in input.
  • CONTINOUS ON MODE : In this mode, AUTO POWER OFF is disabled.
  • DATA Hold Function : By pressing DATA HOLD button, reading on the display can belatched for Hands free operation.
  • MIN,MAX Function : By pressing MIN/MAX button, the clamp meter will start recordinglatest Minimum and Maximum readings
  • NULL ZERO Correction for Resistance : For Low ohm measurement, the lead resistance can be compensated by pressing the shift key (Yellow Key)
  • NULL ZERO Correction for Capacitance : Null zero connection for capacitance. For nF range, stray capacitance can be compensated by shift key (Yellow Key)
  • AUTO and MANUAL ranging modes In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
  • Diode Measurement : For testing diode and transistors, diode measurement function is available.
SPECIFICATIONS:
  • DC Voltage: 2000V
  • AC Voltage: 2000V
  • DC Current: 2000A
  • AC Current: 2000A
  • Resistance: 20 M ohms
  • Capacitance: 2000uF
  FEATURES
  • Display Mode: Display by LCD
  • Maximum Display: 1999
  • Digits: 3 ½ Digits
  • Maximum span of jaw: 55mm
  • Auto Range
  • Inrush Current
  • Resistance
  • Capacitance
  • Diode Test
  • Continuity Test
  • Data Hold
  • LED Testing
  • Back Light + Lamp Light
  • Auto negative polarity indication: displaying ‘-’
  • Auto Power Off
  • Battery: 9V
 
SPECIFICATIONS : 
  • AC VOLTAGE : 750V
  • DC VOLTAGE : 1000V
  • AC CURRENT : 1000A
  • DC CURRENT : 1000A
  • RESISTANCE : 60M
  • CAPACITANCE : 1000µF
  • TEMPERATURE : -0 F~1832ºF
FEATURES : 
  • DISPLAY : 3 5/6 DIGIT DISPLAY
  • POLARITY : AUTO POLARITY
  • SAMPLING RATE : 2~3 TIMES/SECOND
  • POWER : 3V BETTERY
  • JAW OPENING : 50mm
 
SPECIFICATION:
  • DC VOLTAGE       : 600V
  • AC VOLTAGE       : 600V
  • AC CURRENT       : 600A
  • RESISTANCE       : 20 M ohms
  • TEMPERATURE  : Range (-40~750)°C Resolution 1°C                                                                                                                                                                                                                                                                                                                    Accuracy - <400°C±1.0% of rdg + 5 digits ≥400°C±1.5% of rdg + 15 digits
  FEATURES:
  • 3½ Digit
  • 2000 Count
  • Non Contact Voltage (NCV)
  • Clamp Torch
  • Jaw Open: 28mm
  • Auto Power Off (APO)
  • True RMS
SPECIFICATIONS :
  • DC VOLTAGE : 200mV, 2V, 20V, 200V, 1000V
  • AC VOLTAGE : 2V, 20V, 200V, 750V
  • AC CURRENT : 2A, 20A, 200A, 1000A
  • TEMPERATURE : -20 to 750 deg C
  • JAW OPENING : 52mm (max.)
  • RESISTANCE : 200Ω, 2kΩ, 20ΩK, 200kΩ, 2MΩ, 20MΩ
FEATURES : 
  • Auto/Manual Ranging.
  • Temperature, Data Hold.
  • Max, NCV, APO.
SPECIFICATIONS : 
  • DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
  • AC VOLTAGE : 4V, 40V, 400V, 750V
  • RESISTANCE : 4000, 4kQ, 40KQ, 400kQ, 4MQ, 40MQ (auto ranging)
  • DIMENSIONS : 229x69x38 mm
FEATURES : 
  • 1000A AC auto ranging. 3 digit 3999 counts. Data hold, frequency, capacitance. APO ranges.
ContentRISH Clamp 1000A/300A measures important electrical parameters like AC Current (TRMS), DC Current, AC Voltage(TRMS), and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, and Duty cycle and temperature measurement.B-6096 is a 2000V AC/DC and 2000A AC/DC TRUE RMS Digital Clamp meter. It adopts high performance MCU processor. It is of great value as it has high reliability, accuracy, quality and automatic setting range function. The product has a large digital display, full range overload protection, data hold function, under voltage detection, auto shut off function. The TRUE RMS function can accurately measure frequency voltage, suitable for measuring motor and compressor starting current. Along with AC/DC current, AC/DC voltage it can measure resistance, capacitance, continuity test, diode forward voltage drop, LED operating voltage, and other parameters. This instrument is easy to operate and carry making it an ideal tool for electrical measurement. Especially suitable for measuring large currents and starting currents.    HTC Brand best quality Digital 3 ½ digits 600A clamp tester model CM-2000 having AC Voltage from 200mV to 600V, DC Voltage from 200mV to 600v (auto ranging), Ac current  in four ranges (0-2-20-200-600A), Resistance (auto ranging) from 0- 20 M.Ohms, with NCV test, Diode test, sound buzzer in continuity,  data hold, clamp led light.  Instrument is supplied with carrying case, test probes, installed 1.5v cells and instruction manual.Meco 2502T-AUTO AC Digital Clamp Meter is a great product for those who are looking for a reliable and accurate clamp meter. It is easy to use and has a large LCD display that makes it easy to read. The Meco clamp meter is best for those looking for a reasonably priced, long lasting measurement and testing device. This product is known for its quality and durability, making it a great choice for anyone in the market for a reliable clamp meter.Meco Digital Clamp Meter 3150 comes with a number of interesting features such as 3 digit 3999 counts frequency data hold APO ranges and capacitance. It comes with a resistance of 4000 4kQ 40KQ 400kQ 4MQ 40MQ. Highly rated by technical experts this digital clamp meter from Meco is suitable for use in DIY projects as well as industries.
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information