Lutron AM-4201 Digital Anemometer
Read moreSPECIFICATIONS
AIR VELOCITY
- MEASUREMENT : m/s
- RANGE : 0.4-30.0 m/s
- RESOLUTION : 0.1 m/s
- ACCURACY : ± ( 2%+0.2 m/s )
- MEASUREMENT : km/h
- RANGE : 1.4-108.0 km/h
- RESOLUTION : 0.1 km/h
- ACCURACY : ± ( 2%+0.8 km/h )
FEATURES
- The portable anemometer provides fast accurate readings with digital readability and the convenience of a remote sensor separately.
- Multi-functions for air flow measurement: m/s, km/h, ft/min, knots.
- Low-friction ball-bearing design resulting in accuracy at both high and low velocities.
- Conventional twisted vane arms, always a source of unreliability have been eliminated.
- DATA HOLD.
- Compact housing cabinate.
- Wide applications: use this anemometer to check air conditioning & heating systems, measure air velocities, wind speeds, temperature…etc.
- Display : LCD 65 x 25 mm, 3 1/2 digits.
- Power Supply : DC 9V 006P, MN1604(PP3) battery (Heavy Duty Type) or equivalent.
- Dimensions : 168 x 80 x 35mm (6.6 x 3.2 x 1.2 inch)
- Standard Accessories : Instruction Manual, Sensor Probe , Carrying Case
- Operating Humidity : Less than 80 % RH.
-
Lutron AM-4202 Digital Anemometer With Temperature
Read moreSPECIFICATIONS
AIR VELOCITY
- MEASUREMENT : m/s
- RANGE : 0.4-30.0 m/s
- RESOLUTION : 0.1 m/s
- ACCURACY : ± ( 2%+0.2 m/s )
- MEASUREMENT : km/h
- RANGE : 1.4-108.0 km/h
- RESOLUTION : 0.1 km/h
- ACCURACY : ± ( 2%+0.8 km/h )
FEATURES
- The portable anemometer provides fast accurate readings with digital readability and the convenience of a remote sensor separately.
- Multi-functions for air flow measurement: m/s, km/h, ft/min, knots.
- temperature measurement. ℃ ℉
- Low-friction ball-bearing design resulting in accuracy at both high and low velocities.
- Conventional twisted vane arms, always a source of unreliability have been eliminated.
- DATA HOLD.
- Compact housing cabinate.
- Wide applications: use this anemometer to check air conditioning & heating systems, measure air velocities, wind speeds, temperature…etc.
- Temp. Sensor : Naked-bead type k thermocouple probe
- Display LCD 65 x 25 mm
- Operating Temp : 0 ℃ to 50℃ (32℉ to 122℉ ).
- Operating Humidity : Less than 80 % RH.
- Standard Accessories : Instruction Manual, Sensor Probe , Carrying Case
- Dimensions : 168 x 80 x 35mm (6.6 x 3.2 x 1.2 inch)
- Weight : 325 g/0.72 LB.
- Power Consumption : Approx. DC 9 mA
-
LUTRON AM-4204 Hot Wire Anemometer
Read moreSPECIFICATIONS
- Circuit : Custom one-chip of micro-processor LSI circuit.
- Display : 13 mm(0.5″) Super large LCD display. Dual function meter’s display.
- Measurement :
in/s (meters per second)
km/h (kilometers per hour)
if/mm (feet/per minute)
knots (nautical miles per hour)
mile/h(miles per hour)
Temp. -°C, °F.
Data hold. - Sensor Structure : Air velocity: Tiny glass bead thermistor
- Temperature : 0 ℃ to 50 ℃ ( 32 ℉ to 122 ℉)
- Operating Humidity : Less than 80% RH.
- Power Supply : 1.5 V AAA (UM-4) battery x 6 PCs (Alkaline or heavy duty type).
- Memory : Maximum and Minimum with recall.
- Sampling Time: Approx. 0.8 sec
- Data Output : RS 232 PC serial interface
FEATURES- Thermal anemometer, available for very low air velocity measurement
- Slim probe, ideal for grilles & diffusers.
- Combination of hot wire and standard thermistor, deliver rapid and precise measurements even at low air velocity value.
- Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
- Super large LCD with dual function meter’s display, read the air velocity & temp. at the same time.
- Heavy duty & compact housing case.
- Records Maximum and Minimum readings with recall Data hold.
- Auto shut off’ saves battery life.
- Operates from 6 PCS UM-4 batteries.
- RS 232 PC serial interface.
- The portable anemometer provides fast, accurate readings, with digital readability and the convenience of a remote probe separately.
- Multi- functions for air flow measurement:
m/s, km/h, ft/mm, knots. mile/h. - Build in temperature 0C, 0 F measurement.
- Thermistor sensor for Temp. measurement, fast response time.
- Used the durable, long-lasting components, including a strong, light weight ABS- plastic housing case.
- Deluxe hard carrying case.
- Applications : Environmental testing, Air conveyors, Elow hoods, Clean
rooms, Air velocity, Air balancing, Fans/motors/blowers, Furnace
velocity, Refrigerated case, Paint spray booths.
-
LUTRON CO and CO2 meter AQ-9901SD
Read moreSPECIFICATIONS
- Circuit : Custom one-chip of microprocessor LSI circuit.
- Display : LCD size : 52 mm x 38 mm ; LCD with green backlight ( ON/OFF ).
- Measurement :
CO2 (Carbon dioxide )
CO ( Carbon monoxide )
O2 ( Oxygen in air )
Humidity
Dew point Temp., Wet bulb Temp. - Data error number : 0.1% of total saved data max.
- Memory Card : SD memory card. 1 GB to 16 GB.
- Sampling time of display : Approx. 1 second.
- Power Supply : AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.
ELECTRICAL SPECIFICATIONS
- CO2 ( Carbon dioxide )
Range : 0 to 4,000 ppm
Resolution : 1 ppm
Accuracy : ± 40 ppm : 1,000 ppm ; ± 5% of reading : > 1,000 ppm 3,000 ppm ; ± 250 ppm typically : > 3,000 ppm, reference only - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
- CO ( Carbon dioxide )
Range : 0 to 1,000 ppm
Resolution : 1 ppm
Accuracy : ± ( 5% + 2 ppm )
Response Time : < 30 seconds
Sensitivity Drift : < 5% per year - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
- O2 ( Air oxygen )
Range : 0 to 30 %O2.
Resolution : 0.1 %O2.
Accuracy : ± ( 1 % reading + 0.2 % O2 )
Response Time : <= 15 seconds
Sensitivity Drift : < 5% per year
Overload Protection : 100 %O2.
Environment Pressure Range : 0.9 to 1.1 atmosphere. - Temperature :
Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
Resolution : 0.1 Degree
Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
FEATURES
- RS232/USB computer interface.
- Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional .
- Separate probe, easy for remote measurements.
- Complete set of 4 probes : CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe,Humidity/Temp. probe, main meter and the hard carrying case.
- Sampling time for data recorder is 2 seconds to 8 hours
- Alarm setting with the beeper sound output
- Humidity sensor : Precision capacitance sensor
- CO, O2 sensor : Galvanic cell type.
- CO range : 0 to 1,000 ppm x 1 ppm
- O2 range : 0 to 30.0 % x 0.1 %.
- CO2 range : 0 to 4,000 ppm x 1 ppm.
-
LUTRON DL-6054 AC LEAKAGE TESTER
Read moreSPECIFICATIONS
- Current Range (AC) : 200mA – 200A
- AC Current Resolution : 0.1mA – 0.1A
-
Current Accuracy (AC) : ± ( 1.2 % + 5d )
-
Jaw Opening Size : 19mm
-
Operating Temperature : 0˚C ~ 50˚C
- Battery : 9V battery
FEATURES
- High precision AC mA measurement, it is useful for AC mA leakage current measurement.
- Measure AC mA on the inductive conductor.
- Miniature type, easy to carry out & operation.
- High precision for low ACA leakage current measurement.
- Built-in DATA HOLD function.
- Crystal time base, high quality.
- LCD display allows clear readout-out even at high ambient light level.
- LSI circuit provides high reliability and durability.
- Overload protection circuit is provided for all range.
- Design to meet IEC 1010 safety requirement.
- Compact, light weight and excellent operation.
-
LUTRON DO-5509 DISSOLVED OXYGEN METER
Read moreSPECIFICATIONS
- Display : 13 mm ( 0.5″ ) LCD, 3 1/2 digits.
- Measurement Range : Dissolved Oxygen – 0 to 20.0 mg/L.
- Resolution : 0.1 mg/L.
- Accuracy : ± 0.4 mg/L. (after calibration within 23± 5 ) ℃
- Sensor Temp Compensation : Automatic from 0 to 40 . ℃
- Panel adj. knob : ZERO knob, CAL knob.
- Battery : 006P DC 9V battery ( heavy duty ).
- Power Consumption : Approx. DC 3.5 mA.
- Operating Temp. : 0 to 50 (32 to 122 ). ℃ ℃℉ ℉
- Operating Humidity : Less than 80% RH.
GENERAL DESCRIPTION
- This Digital Dissolved Oxygen Meter is supplied with a polarographic type probe with an incorporated Temp. sensor which serves for precise Dissolved Oxygen ( DO ) and Temp. measurement.
- Applications for Aquarium, Medical research, Agriculture, Fish hatcheries, Laboratory, Water conditioning, Mining industry, Schools & Colleges, Quality control.
-
LUTRON FG-5000A FORCE GUAGE
Read moreSPECIFICATIONS
- Measuring Parameters : Tension & Compression
- Range : 5000 g/176.40 oz/49.03 Newton.
- Accuracy : ± (0.4 % + 1 d), within 23± 5 . ℃
- Resolution : 1 g/0.05 oz/0.01 Newton.
- Display : LCD ( Liquid crystal display ).5 digits, 10 mm ( 0.4″ ) digit size
- Operating Temperature : 0 to 50 C( 32 to 122 F).
- Operating Humidity : Less than 80% RH
- Power Supply : 6 x 1.5 V AA (UM-3) size battery or DC 9V adapter (not included).
- Dimensions : 227 X 83 X 39 mm ( 8.9 X 3.3 X 1.5 inch ).
- Weight : 551g
SPECIFICATIONS
- Tension & compression capability.
- 5000 g, wide capacity, high resolution, high accuracy, high repeatability.
- 3 kind display unit, g/oz/Newton.
- Separate sensor.
- Peak hold ( Max. load ) measurement.
- Zero buttons can operate both for normal & ” peak hold ” operation.
- Full capacity zero (tare) capability.
- Fast/Slow response time.
- Positive or reverse display direction.
- Handheld & stand mounting.
- Microprocessor circuit & exclusive load cell transducer.
- Overload protection.
- RS-232 computer interface.
-
Lutron GCH 2018 IAQ Monitor CO2 Meter + Humidity & Temperature
Read moreSPECIFICATIONS
- Circuit : Custom one-chip of microprocessor LSI circuit.
- Display : LCD size : 52 mm x 38 mm dual function LCD display.
- Measurement : CO2 ( Carbon dioxide ), Temp. Humidity, Dew point, Temp.
- HUMIDITY :
Range : 10 % to 95 % R.H
Resolution : 0.1 % R.H.
Accuracy : ≧ 70% RH : ≧ ± (3% reading + 1% RH). ; < 70% RH : ± 3% RH. - Temperature :
Range : 0 to 50 ,32 to 122 .
Resolution : 0.1 Degree
Accuracy : ℃ : -0.8℃ ; ℉ : – 1.5 ℉ - Dew Point
Range : -25.3 ℃ to 48.9 ℃
Resolution: 0.1℃Range : -13.5℉ to 120.1℉
Resolution : 0.1℉ - Operating Temperature : 0 to 50 . ℃
- Operating Humidity
Main instrument : Less than 85% R.H.
C02 probe : Less than 85% R.H.
Humidity probe : 0 to 95 %RH. - Power Supply : DC 1.5 V battery ( UM4, AAA ) x 6 PCs, or equivalent.
- Alarm setting : For CO2 measurement only.
FEATURES
- High repeatability and high accuracy
- Auto shut off is available to save battery life.
- Power supply from batteries or DC 9V adapter in.
- Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation.
- Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
- Dimensions : 173 x 68 x 42 mm (7.9 x 2.7x 1.2 inch)
- Accessories Included :
Instruction manual 1 PC
CO2 probe 1 PC
Humidity probe 1 PC
Hard Carrying case .1 PC - Humidity measurement with fast response time.
- Large S-TN LCD, high contrast, easy readout.
- CO2 function with alarm setting.
- Separate probe, easy operation and convenient for remote measurement.
- Two probes, one is for CO2/Temp. measurement, other probe is for Humidity/Temp./Dew point measurement
-
Lutron LM-8102 – Sound, Anemometer, Anemometer, %RH, Temp., Type K (5 IN 1 METER)
Read moreSPECIFICATIONS
- Operating Humidity : Max. 80 %RH.
- Operating Temperature : 0 to 50° C (32 to 122° F)
- Dimension : HWD 248 x 70 x 34 mm ( 9.8 x 2.8 x 1.3 inch).
- Weight : 335 g/0.74 LB ( battery included ).
FEATURES
-
- 5 in 1 professional measuring instrument: Anemometer, Type K Thermometer , Hygrometer, Light meter, Sound level meter.
- Anemometer use low-friction ball bearing mounted wheel design provides high accuracy
- Light meter use exclusive photo diode and color correction filter light sensor, spectrum meets C.I.E. photopic.
- Type K thermometer use standard type K (NiCr-NiAl) thermocouple input jack suitable for all kinds of type K probe\
- Humidity meter use high precision humidity sensor with fast response time.
- Sound level meter can cooperate the external 94 dB sound calibrator and just press the front buttons to make the calibration
- Built- in microprocessor circuit assures excellent performance and accuracy
-
LUTRON LX-1102 DIGITAL LUX METER
Read moreSPECIFICATIONS
- Range : 40.00 Lux to 400,000 Lux
- Accuracy : ± ( 3% rdg + 0.5 % F.S )
- Resolution : 0.01 Lux to 100 Lux
- Display : Large LCD dispaly, LCD size 52 x 38 mm, 4 digits with bargraph indicator.
- Unit Selection : Lux, Foot-candle ( Ft-cd )
- Operating Temperature : 0 to 50 ℃
- Operating Humidity : Max. 80% RH
- Sensors : The exclusive photo diode & color correction filter, spectrum meet C.I.E. Cosine correction factor meet standard
- Power : DC 9V battery. 006P,MN1604 ( PP3 ) or equivalent.
- Dimensions : 200 X 68 X 30 mm
- Weight : 220g
FEATURES
- This Digital Lux Meter has Water resistance for the front panel
- Data hold function
- Memory function to display the max. & min display value with Recall.
- LSI circuit provides high reliability and durability
- Built-in low battery indicator.
-
LUTRON MS-7000 MOISTURE METER
Read moreSPECIFICATIONS
- Applications : For surveying buildings for dampness and for the rapid determination of the moisture content of wood/timber.
- Principal : Used the 2 pins electrode to measure the conductive ability of the species, then converter to the reading of % ” Moisture of Content “.
- Default Memory for 9 material species groups in memory, calibrations for about 150 the species different species of wood are provided.
- Circuit Custom one-chip of microprocessor LSI circuit.
- Display : 13 mm ( 0.5″ ) super large LCD display, dual function meter’s display.
- Measurement : Measure moisture content over range 9 % to 30 %.
- Probe : Separate 2 pins moisture electrode,
- Temperature : Manual temperature compensation of the meter in the range of 0 Compensation to 50 . ℃
- Calibration : Built-in self-calibration circuit by push button on front panel.
- Data Hold By push button on front panel.
- Memory Recall Records Maximum & Minimum reading value.
- Power off Auto shut off, saves battery life, or manual off by push button.
- Sampling Time : Approx. 0.8 second.
- Data Output : RS 232 PC serial interface.
- Operating Temperature : 0 to 50 . ℃
- Operating Humidity : Less than 80% R.H.
- Power Supply : 006P, MN1604 ( PP3 ) DC 9V battery or equivalent, recommend use the alkaline or heavy duty battery.
FEATURES:
- Measure moisture content over range 9 % to 30 %.
- Heavy duty & compact housing case, designed for easy carry out & operation.
- 9 material species groups memory, calibrations for about 150 different species of wood/timber are provided.
- Built-in self-calibration circuit.
- 0 to 50 manual temperature ℃ compensation setting.
- Microprocessor circuit.
- Records Max. & Min. reading.
- Data hold.
- Separate pin type moisture probe, easy operation. & remote
measurement. - RS232 computer interface.
-
Lutron Pen Vibration Meter PVB-820
Read moreSPECIFICATIONS
- Frequency Range : 10 Hz to 1 KHz
- Zero Adjust : Build in the Zero adjustment VR, easy to make adjustment.
- Operating Temperature : 0°C to 50°C ( 32°F to 122°F ).
- Operating Humidity : Less than 80% RH
- Power Supply : DC 1.5V battery ( UM-4/AAA ) x 4 PCs
- Dimensions : 175 x 40 x 32 mm
- Weight : 240 g ( 0.53 lb )
FEATURES
- Applications for industrial vibration monitoring : All industrial machinery vibrates. The level of vibration is a useful guide to machine condition. Poor balance, misalignment & looseness of the structure will cause the vibration level increase, it is a sure sign that the maintenance is needed
- Pen type digital vibration meter, vibration sensor is built in, all in one.
- Acceleration, Velocity measurement, RMS measurement value.
- Metric & Imperial display unit
- Frequency range 10 Hz – 1 kHz, sensitivity relative meet ISO 2954.
- Microcomputer circuit, intelligent function, high accuracy.
- LCD display, easy read out.
- Complete set with the Test pin and the Magnetic base are the standard accessories.
- Built-in low battery indicator.
- Heavy duty & compact housing case.
- IP65 protection.
- Compact size, light weight.
- Soft carrying case is the optional accessory