HIOKI AC/DC CLAMP METER CM4373-50

Brands:
Category:

Availability: In Stock

SPECIFICATIONS 

  • DC Current Range : 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)
  • AC Current Range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)
  • Crest factor : 600.0 A range: 3 or less ; 2000 A range: 2.84 or less
  • DC+AC Current range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)
  • DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
  • AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
  • DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
  • Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
  • Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
  • Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
  • Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
  • Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz

FEATURES

  • CAT IV 600 V, CAT III 1000 V
    When using P2000: CAT III 2000 V, CAT IV 1000 V
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
  • Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
  • Automatic AC/DC function helps boost work efficiency
Category:

Description

CLAMPMETER Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4373-50 is a 2000 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.

Reviews

There are no reviews yet.

Be the first to review “HIOKI AC/DC CLAMP METER CM4373-50”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHIOKI AC/DC CLAMP METER CM4373-50 removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO 1080 TRMS DIGITAL CLAMPMETER removeMECO-G R-2025 DIGITAL CLAMPMETER removeMECO G R-1818T DIGITAL CLAMP METER removeMECO DT-2250Hz AUTO DIGITAL CLAMPMETER remove
NameHIOKI AC/DC CLAMP METER CM4373-50 removeMECO-G R-DT903A-1 DIGITAL INSULATION RESISTANCE TESTER removeMECO 1080 TRMS DIGITAL CLAMPMETER removeMECO-G R-2025 DIGITAL CLAMPMETER removeMECO G R-1818T DIGITAL CLAMP METER removeMECO DT-2250Hz AUTO DIGITAL CLAMPMETER remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionSPECIFICATIONS 
  • DC Current Range : 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)
  • AC Current Range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)
  • Crest factor : 600.0 A range: 3 or less ; 2000 A range: 2.84 or less
  • DC+AC Current range : 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)
  • DC Voltage range : 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
  • AC Voltage range : 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
  • DC+AC Voltage range : 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 - 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
  • Resistance range : 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
  • Capacitance range : 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
  • Frequency range : 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
  • Temperature (K) : -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
  • Voltage detection : Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
FEATURES
  • CAT IV 600 V, CAT III 1000 V When using P2000: CAT III 2000 V, CAT IV 1000 V
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file (*2)
  • Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
  • Automatic AC/DC function helps boost work efficiency
SPECIFICATIONS :
  • DC VOLTAGE TEST : 0V~1000
  • AC VOLTAGE TEST : 0V~750
  • BATTERY  VOLTAGE : 1.5 V
  • RESISTANCE : 500 MW/1000 V
  •  TEMPERATURE : -10 to 50 deg C(RH £ 75%)
FEATURES : 
  • Inbuild Protection Circuit to prevent the harm of reverse voltages.
  • LCD Back Light Function with Indicator Switch.
  • 3 Ranges of Insulation Measurement.
SPEIFICATIONS : 
  • DC VOLTAGE RANGE : 600 mV-1000 V
  • AC VOLTAGE RANGE : 600 mV-750 V
  • DC ACCURACY : ±(0.5 % + 3 Digits)
  • AC ACCURACY : ±(0.8 % + 5 Digits)
  • AC CURRENT : Above 1000 A
  • DC CURRENT : 600 µA-1200 A
  • DISPLAY : 3⅚ Digits LCD Display
  • FREQUENCY : 99.99 Hz-20 MHz
  • TEMPERATURE : -20° to 1000°C
  • RESISTANCE : 0-60 MΩ
  • DIMENSIONS : 238x90x48 mm
FEATURES : 
  • True Rms.
  • 6000 Counts Lcd Display with Backlight.
  • Low Battery Indications.
  • Continuity Buzzer.
  • Diode Checking & Temperature.
SPECIFICATIONS :
  • AC VOLTAGE : 750V
  • DC VOLTAGE : 1000V
  • AC CURRENT : 200A
  • RESISTANCE : 2M ohms
  • CONTINUITY TEST : 20KHz
FEATURES :
  • TRANSFORMER JAWS
  • TIGGER
  • DATA HOLD SWITCH
  • ROTARY SWITCH
  • 3 1/2 DIGITS DISPLAY
  • BACK LIGHT SWITCH
  • COM INPUT TERMINAL
  • V/OHM INPUT TERMINAL
SPECIFICATIONS : 
  • AC VOLTAGE : 750V
  • DC VOLTAGE : 1000V
  • AC CURRENT : 1000A
  • DC CURRENT : 1000A
  • RESISTANCE : 60M
  • CAPACITANCE : 1000µF
  • TEMPERATURE : -0 F~1832ºF
FEATURES : 
  • DISPLAY : 3 5/6 DIGIT DISPLAY
  • POLARITY : AUTO POLARITY
  • SAMPLING RATE : 2~3 TIMES/SECOND
  • POWER : 3V BETTERY
  • JAW OPENING : 50mm
 
SPECIFICATIONS : 
  • DC VOLTAGE RANGE : 4-1000 V (Auto Ranging)
  • AC VOLTAGE RANGE : 4 to 750V (Auto Ranging)
  • AC VOLTAGE : 4V, 40V, 400V, 750V (Auto) (40-500Hz)
  • DC VOLTAGE : 4V, 40V, 400V, 1000V (auto)
  • FREQUENCY  RANGE : 10 Hz, 50 Hz & 500 Hz
  • FREQUENCY ACCURACY : ±(0.5% rdg + 2 dgt)
  • RESISTANCE : 400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (Auto)
  • DIMENSION : 250x98x35 mm
FEATURES : 
  • Automatic.
  • 3 V Sensitivity.
  • Select Button.
  • Data Hold Button.
  • Audible Continuity Check.
  • Diode Test Functions.
  • Low Battery Indications.
  • Over Volt Protections 200V DC and AC Peak.
  • Automatic, Positive Implied, Negative Polarity Indication.
ContentCLAMPMETER Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4373-50 is a 2000 A True RMS clamp meter that features stronger jaws, IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.MECO-G Digital Insulation Resistance Tester, R-DT903A is a premium quality product from MECO-G. All MECO-G Digital Insulation Resistance Tester, R-DT903A are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field. The materials utilized to manufacture MECO-G Digital Insulation Resistance Tester, R-DT903A, are sourced from the most reliable and official vendors, chosen after performing detailed market surveys. MECO-G products are widely acknowledged in the market for their high quality. We are dedicatedly involved in providing an excellent quality array of MECO-G Insulation Testers .The Meco 1080 TRMS Digital AC/DC Clamp Meter True RMS 1200 A 750 V is a great tool for electricians and contractors. It is a true RMS meter, meaning it measures the actual voltage and current, making it the only choice for measuring AC and DC signals. The Meco 1080-TRMS digital AC/DC clamp meter is a must-have for any electrician or technician. This ergonomic and lightweight meter is easy to use, with a large, backlit LCD display for clear readings. The meter has a wide range of capabilities, including measuring AC and DC voltage, AC and DC current, and resistance. With accuracy of (0.5 % + 3 Digits), the Meco 1080-TRMS is a reliable tool for any electrical job. The SENSO-30 clamp meter is a versatile tool for quickly and accurately measuring the terminal dimensions of cables and wires. The jaws are open 30 mm, which makes it easy to get a close reading on wires and cables.The MECO-G 1000A AC Digital Auto Ranging Clamp Meter is a great choice for those who need a reliable and accurate clamp meter. It features a large jaw opening for easy clamping, auto ranging for easy use, and a backlit LCD display for easy reading. The MECO-G clamp meter is a great choice for measuring dc voltage and current, as well as ac current. It has a range of 600mV to 6V, 60V to 600V, and 1000V, making it suitable for a variety of applications. The ac current range is 60A to 600A, and 1000A, with an accuracy of  (2.5% of reading + 10 digits). The clamp meter also features a resistance accuracy of  (1.5% of reading + 5 digits).Meco Digital Clamp Meter 2250-HZ comes with an assortment of features like data hold diode test data hold and % duty cycle. It is equipped with 2250-Hz Auto 10000A AC 3 digit 3999 counts APO frequency and data hold.
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information