LUTRON CO and CO2 meter AQ-9901SD

Brands:

Availability: In Stock

SPECIFICATIONS

  • Circuit : Custom one-chip of microprocessor LSI circuit.
  • Display : LCD size : 52 mm x 38 mm ; LCD with green backlight ( ON/OFF ).
  • Measurement :
    CO2 (Carbon dioxide )
    CO ( Carbon monoxide )
    O2 ( Oxygen in air )
    Humidity
    Dew point Temp., Wet bulb Temp.
  • Data error number : 0.1% of total saved data max.
  • Memory Card : SD memory card. 1 GB to 16 GB.
  • Sampling time of display : Approx. 1 second.
  • Power Supply : AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.

ELECTRICAL SPECIFICATIONS

  • CO2 ( Carbon dioxide )
    Range : 0 to 4,000 ppm
    Resolution : 1 ppm
    Accuracy : ± 40 ppm : 1,000 ppm ; ± 5% of reading : > 1,000 ppm 3,000 ppm ; ± 250 ppm typically : > 3,000 ppm, reference only
  • Temperature :
    Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
    Resolution : 0.1 Degree
    Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5

 

  • CO ( Carbon dioxide )
    Range : 0 to 1,000 ppm
    Resolution : 1 ppm
    Accuracy : ± ( 5% + 2 ppm )
    Response Time : < 30 seconds
    Sensitivity Drift : < 5% per year
  • Temperature :
    Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
    Resolution : 0.1 Degree
    Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5

 

  • O2 ( Air oxygen )
    Range : 0 to 30 %O2.
    Resolution : 0.1 %O2.
    Accuracy : ± ( 1 % reading + 0.2 % O2 )
    Response Time : <= 15 seconds
    Sensitivity Drift : < 5% per year
    Overload Protection : 100 %O2.
    Environment Pressure Range : 0.9 to 1.1 atmosphere.
  • Temperature :
    Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉
    Resolution : 0.1 Degree
    Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5

FEATURES 

  • RS232/USB computer interface.
  • Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional .
  • Separate probe, easy for remote measurements.
  • Complete set of 4 probes : CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe,Humidity/Temp. probe, main meter and the hard carrying case.
  • Sampling time for data recorder is 2 seconds to 8 hours
  • Alarm setting with the beeper sound output
  • Humidity sensor : Precision capacitance sensor
  • CO, O2 sensor : Galvanic cell type.
  • CO range : 0 to 1,000 ppm x 1 ppm
  • O2 range : 0 to 30.0 % x 0.1 %.
  • CO2 range : 0 to 4,000 ppm x 1 ppm.

Description

Lutron AQ-9901SDThe device is designed to measure air quality – it also measures CO, CO2, O2 levels, temperature and dew point. The measured data is recorded on an SD card in Excel format, where it can be further processed. The instrument can also be used as an indicator, and it also has the option of setting an alarm – a warning sound signal when the defined value is exceeded.

Reviews

There are no reviews yet.

Be the first to review “LUTRON CO and CO2 meter AQ-9901SD”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsLUTRON CO and CO2 meter AQ-9901SD removeLutron GCH 2018 IAQ Monitor CO2 Meter + Humidity & Temperature remove
NameLUTRON CO and CO2 meter AQ-9901SD removeLutron GCH 2018 IAQ Monitor CO2 Meter + Humidity & Temperature remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

DescriptionSPECIFICATIONS
  • Circuit : Custom one-chip of microprocessor LSI circuit.
  • Display : LCD size : 52 mm x 38 mm ; LCD with green backlight ( ON/OFF ).
  • Measurement : CO2 (Carbon dioxide ) CO ( Carbon monoxide ) O2 ( Oxygen in air ) Humidity Dew point Temp., Wet bulb Temp.
  • Data error number : 0.1% of total saved data max.
  • Memory Card : SD memory card. 1 GB to 16 GB.
  • Sampling time of display : Approx. 1 second.
  • Power Supply : AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.
ELECTRICAL SPECIFICATIONS
  • CO2 ( Carbon dioxide ) Range : 0 to 4,000 ppm Resolution : 1 ppm Accuracy : ± 40 ppm : 1,000 ppm ; ± 5% of reading : > 1,000 ppm 3,000 ppm ; ± 250 ppm typically : > 3,000 ppm, reference only
  • Temperature : Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉ Resolution : 0.1 Degree Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
 
  • CO ( Carbon dioxide ) Range : 0 to 1,000 ppm Resolution : 1 ppm Accuracy : ± ( 5% + 2 ppm ) Response Time : < 30 seconds Sensitivity Drift : < 5% per year
  • Temperature : Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉ Resolution : 0.1 Degree Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
 
  • O2 ( Air oxygen ) Range : 0 to 30 %O2. Resolution : 0.1 %O2. Accuracy : ± ( 1 % reading + 0.2 % O2 ) Response Time : <= 15 seconds Sensitivity Drift : < 5% per year Overload Protection : 100 %O2. Environment Pressure Range : 0.9 to 1.1 atmosphere.
  • Temperature : Range : 0 ℃ to 50 ℃ ; 32 ℉ to 122 ℉ Resolution : 0.1 Degree Accuracy : ℃ : ± 0.8 ; ℉ : ± 1.5
FEATURES 
  • RS232/USB computer interface.
  • Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional .
  • Separate probe, easy for remote measurements.
  • Complete set of 4 probes : CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe,Humidity/Temp. probe, main meter and the hard carrying case.
  • Sampling time for data recorder is 2 seconds to 8 hours
  • Alarm setting with the beeper sound output
  • Humidity sensor : Precision capacitance sensor
  • CO, O2 sensor : Galvanic cell type.
  • CO range : 0 to 1,000 ppm x 1 ppm
  • O2 range : 0 to 30.0 % x 0.1 %.
  • CO2 range : 0 to 4,000 ppm x 1 ppm.
SPECIFICATIONS
  • Circuit : Custom one-chip of microprocessor LSI circuit.
  • Display : LCD size : 52 mm x 38 mm dual function LCD display.
  • Measurement : CO2 ( Carbon dioxide ), Temp. Humidity, Dew point, Temp.
  • HUMIDITY : Range : 10 % to 95 % R.H Resolution : 0.1 % R.H. Accuracy : ≧ 70% RH : ≧ ± (3% reading + 1% RH). ; < 70% RH : ± 3% RH.
  • Temperature : Range : 0 to 50 ,32 to 122 . Resolution : 0.1 Degree Accuracy : ℃ : -0.8℃ ; ℉ : - 1.5 ℉
  • Dew Point Range : -25.3 ℃ to 48.9  ℃ Resolution: 0.1℃Range : -13.5℉ to 120.1℉ Resolution : 0.1℉
  • Operating Temperature : 0 to 50 . ℃
  • Operating Humidity Main instrument : Less than 85% R.H. C02 probe : Less than 85% R.H. Humidity probe : 0 to 95 %RH.
  • Power Supply : DC 1.5 V battery ( UM4, AAA ) x 6 PCs, or equivalent.
  • Alarm setting : For CO2 measurement only.
FEATURES
  • High repeatability and high accuracy
  • Auto shut off is available to save battery life.
  •  Power supply from batteries or DC 9V adapter in.
  • Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation.
  • Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
  • Dimensions : 173 x 68 x 42 mm (7.9 x 2.7x 1.2 inch)
  • Accessories Included : Instruction manual 1 PC CO2 probe 1 PC Humidity probe 1 PC Hard Carrying case .1 PC
  • Humidity measurement with fast response time.
  • Large S-TN LCD, high contrast, easy readout.
  • CO2 function with alarm setting.
  • Separate probe, easy operation and convenient  for remote measurement.
  • Two probes, one is for CO2/Temp. measurement, other probe is for Humidity/Temp./Dew point measurement
ContentLutron AQ-9901SDThe device is designed to measure air quality - it also measures CO, CO2, O2 levels, temperature and dew point. The measured data is recorded on an SD card in Excel format, where it can be further processed. The instrument can also be used as an indicator, and it also has the option of setting an alarm - a warning sound signal when the defined value is exceeded.Lutron GCH-2018 IAQ Monitor gives you a chance to measure, precisely, and reasonably test CO2 levels, Temperature and Humidity around your environment. It tends to be moved from spot to place to test CO2 levels, temperature and Humidity in your environment. IAQ Monitor can uncover if your condition’s warming, ventilation and cooling framework is working appropriately. Applications : Houses, HVAC, Pharmaceuticals, Industries, Green house, Smart Homes, Offices etc.
Weight
DimensionsN/AN/A